TTK 600

  • Low Temperature Chamber TTK 600
  • Low Temperature Chamber TTK 600
  • Low Temperature Chamber TTK 600
  • Low Temperature Chamber TTK 600
  • Non-ambient attachment for X-ray diffraction studies from -190 °C to 600 °C
  • For investigations on samples in reflection and transmission geometry
  • Also for air-sensitive samples and in-operando studies on batteries
  • Fits to all common powder diffractometers
Pick your country.
Americas
Brazil
PT
Canada
EN | FR
Colombia
ES
Mexico
ES
Peru
ES
United States
EN
Europe
Austria
DE
Belgium
EN | FR
Croatia
EN
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Africa & Middle East
South Africa
EN
Turkey
TR
United Arab Emirates
EN
Asia-Pacific
Australia
EN
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Philippines
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
EN
Vietnam
EN | VI
If you can't find your country in the list get a quote

The TTK 600 Low-Temperature Chamber is a non-ambient attachment for powder X-ray diffraction studies from -190°C to 600°C. Different sample holders allow investigating samples in reflection and transmission geometry. Samples can be measured in vacuum, air or inert gases. An antechamber option allows safe transfer of air-sensitive samples into the TTK 600.

The TTK 600 fits to all common powder diffractometers and is the instrument of choice for X-ray structure analysis of various sample types at low and medium temperatures.

Key features

Fast and accurate temperature control

  • Liquid nitrogen cooling to -190°C or compressed air cooling to -10°C
  • Resistance heating for rapid heating up to 600°C
  • Pt100 close to the sample for precise temperature measurement
  • Flexible liquid nitrogen hoses for movability even at -190°C
  • Improved heat transfer from heater to sample holder. Additional convection heating for the capillary sample holder and the transmission sample holder for reduced temperature deviation

Optimized for maximum sample flexibility

  • Various types of sample holders:
    • Standard sample holder for the investigation of powders in reflection geometry (different depths available)
    • Capillary sample holder for the investigation of powders in transmission geometry
    • Transmission sample holder for the investigation of foils, pastes and powders in transmission mode
  • Zero background holder for transparent samples
  • Integrated beam knife to minimize background at low 2θ
  • Easy exchange and mounting of samples

Specifications

Operating temperature-190 °C to 600 °C with liquid nitrogen cooling
-10 °C to 600 °C with compressed-air cooling
Temperature measurementPt 100
AtmosphereVacuum (10-2 mbar), air, inert gas
Angle of incidence (2Θ)0 to 164 ° (standard sample holder)
Max. operating pressure2 bar above atmospheric pressure
Sample holder materialChromium-plated copper
Sample size14 x 10 mm

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Categories
Industry
Application
Your choice: Reset all filters

Compatible instruments