This is a required field.
Invalid
Part number
Error in validation!

Laser Diffraction Particle Size Analyzer:
Litesizer DIF

  • media
  • +8
Model:
  • Measurement of samples from 0.1 µm to 1,000 µm
  • Switching between liquid and dry dispersion in just one move
  • Kalliope software: No training required, dedicated QC mode
  • Reliable results even in harsh environments
Pick your country.
Americas
Brazil
PT
Canada
EN | FR
Colombia
ES
Mexico
ES
Peru
ES
United States
EN
Europe
Austria
DE
Belgium
EN | FR
Croatia
EN
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Africa & Middle East
South Africa
EN
Turkey
TR
United Arab Emirates
EN
Asia-Pacific
Australia
EN
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Philippines
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
EN
Vietnam
EN | VI
If you can't find your country in the list get a quote

The Litesizer DIF series offers advanced particle sizing from 10 nm to 3.5 mm, drawing on nearly 60 years of laser diffraction expertise. This laser diffraction particle size analyzer has a best-in-class optical setup featuring powerful 10 mW and 25 mW lasers and the widest range on the market of detected diffraction angles from 0.01° to 170°. The Kalliope software simplifies particle sizing, requiring no extensive training – measurements start with just three clicks. The Quick-Click system allows easy switching between dispersion units, minimizing errors. Safety features for both liquid and dry dispersion ensure effortless, secure operation. 

The robust metal housing and the isolated optical bench deliver reliability everywhere: from harsh environments, to high-tech laboratories.

Fueled by our pioneering legacy, this is next-generation laser diffraction technology – the Litesizer DIF series: From First to Best.

Key features

Particle sizing in any environment

Anton Paar's Litesizer DIF is suitable for heavy industries. It is made of high-quality components inside and out. Sturdy metal housing encases durable optical elements. Litesizer DIF is built to endure harsh environments: No dust or powder can penetrate into the optical bench of the instrument, and the inside of the instrument is isolated from possible direct vibrations at the production site. All of this means savings on upkeep and repair costs.

Kalliope: The benchmark software for particle sizing

With Kalliope, users immediately know how to get started, via the one-page-only workflow (setting parameters, acquiring and working with results). Additionally, the QC mode offers consistent reliable measurement results by customizing user management and locking delicate settings. The instrument in QC mode gives simple feedback if your product is within your defined limits. This means results in just three clicks and less training for new users. In addition, a pharma option with data security functions, user management, and audit trails is included, making Kalliope compliant with the US FDA’s 21 CFR Part 11.

Efficient dispersion, maximum safety

Litesizer DIF's Quick-Click feature connects the dispersion units in just one move – no hassle with cables, tubes or pipes. The obscuration level indicator allows monitoring of the sample amount while adding it, ensuring the right amount from the start. 

The Dry Jet dispersion unit has a suction check and built-in dust cover to minimize the risk of powder spread. 

The Liquid Flow unit automatically checks for sufficient liquid before sonication, preventing overheating. A dedicated module with high chemical resistance is available for aggressive liquids. 

The Liquid Flow Imaging unit combines laser diffraction and dynamic image analysis adding shape parameters of particles from 5 µm in size.

On quality, we lead the way

Litesizer DIF is the perfect tool for particle analysis due to its high-quality manufacturing. It features high-grade hardware, empowering the instrument to collect superior raw data. This laser diffraction particle size analyzer enables users to measure a broad range of samples, covering particle sizes from 0.01 µm to 3,500 µm, all with a single analyzer – without the need for additional investment.

Less investment, saved bench space – compatibility across the board

Compatibility of dispersion units between Anton Paar’s Litesizer DIA and Litesizer DIF instruments reduces investment costs and lab space usage. On top of that, all Litesizer instruments can be operated using a single PC with the Kalliope software installed.

Specifications

 Litesizer DIF 500Litesizer DIF 300Litesizer DIF 100
Measurement principleLaser Diffraction (Mie and Fraunhofer scattering)
Measurement range0.01 μm - 3,500 μm0.1 μm - 2,500 μm0.1 μm - 1,000 μm
Size classes144 (user adjustable)114 (user adjustable)104 (user adjustable)
Accuracy *better than ± 0.5 % variation***
Repeatabilitybetter than ± 0.5 % variation***
Reproducibility**better than ± 1 % variation***
Possible measurement duration<10 sec
Data acquisition rate16 kHz
Light source 1 
TypeFiber coupled laser diode
Optical arrangementReverse Fourier
Wavelength830 nm, infrared
Power10 mW
Laser ClassClass 1 (IEC60825-1)
Light source 2Litesizer DIF 500-
TypeLaser diode-
Optical arrangementTilted relative to IR laser-
Wavelength450 nm, blue-
Power25 mW-
Laser ClassClass 1 (IEC60825-1)-
Detectors 
TypeLog-spaced photo diode array and single diodes for side and back-scattering
Angular range0.01° - 170°0.01° - 155° 
Focal length300 mm
AlignmentAutomatic
Instrument data 
Instrument dimensions****400 mm x 790 mm x 290 mm (H x W x D)
Instrument weight****42.3 kg (93.2 lb)
Power supply100 V to 240 V ±10 %, 50/60 Hz

Trademarks: 
• Kalliope (EU: 012709391), (UK: UK00912709391) 
• Litesizer (EU: 011695491), (UK: UK00911695491) 

* Defined for a monomodal latex standard and accounting for manufacturer's uncertainty of standard size. 
** Defined for D50 of a polydisperse standard. 
*** Sample and preparation dependent. Defined for liquid dispersion measurements. 
**** Without PC and dispersion uni

Standards

Open all
Close all

CFR

21 Part 11

Standards

Open all
Close all

CFR

21 Part 11

Standards

Open all
Close all

CFR

21 Part 11

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Categories
Industry
Application
Your choice: Reset all filters

No results found!

Similar products

Complementary products

Product Type
  • Accessory
  • Software
Category
  • Autosampler
  • Laboratory Software
  • Miscellaneous

Automation Option for Particle Analysis:
Litesizer Autosampler 

Compatible with :
Litesizer DIF 100 | 300 | 500
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Measure liquid and dry samples
  • Measure up to 60 samples per run
  • Add and prioritize samples even during an active run
  • Ensure safety with cobot functionality

Accessory for Litesizer DIA and DIF:
Dispersion Unit Liquid Flow

Compatible with :
Litesizer DIF 500
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 261786
Product details
  • Dispersion of samples using a carrier liquid
  • Automated filling, draining, and rinsing of the dispersion liquid
  • Prevention of overheating with automatic recognition of liquid
  • Dedicated version with high chemical resistance available for handling aggressive liquids
  • Available for the Litesizer DIA and Litesizer DIF series

More info

Accessory for Litesizer DIA and DIF:
Dispersion Unit Dry Jet

Compatible with :
Litesizer DIF 500
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 261787
Product details
  • Dispersion of samples using pressurized air
  • Automation for optimal sample feeding rate
  • Prevention of toxic or explosive sample spread with safety cover
  • Containment of dangerous samples with automatic suction check
  • Available for the Litesizer DIA and Litesizer DIF series

More info

Accessory for Litesizer DIA and DIF:
Dispersion Unit Liquid Flow Imaging

Compatible with :
Litesizer DIF 500
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Combination of laser diffraction and dynamic image analysis
  • Measurement of shape parameters from 5 µm to 2,500 µm
  • Dispersion of samples using a carrier liquid
  • Inclusion of all features of the liquid flow dispersion unit
  • Only available for the Litesizer DIF series

More info

Particle Analysis Software:
Kalliope 

Compatible with :
Litesizer DIF 500
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Particle analysis software for all Litesizer instruments
  • Particle measurement start in just three clicks
  • One-page workflow user interface
  • Live monitoring of measurement results, analysis function

Accessory for Litesizer DIA and DIF:
Dispersion Unit 

Compatible with :
Litesizer DIF 500
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
See more