Domed Hot Stage for Four-Circle Goniometers:
DHS 1100

  • Domed Hot Stage for Four-Circle Goniometers DHS 1100 with graphite dome for high-temperature X-ray studies of polycrystalline samples and thin films from 25 to 1100 °C
  • Domed Hot Stage for Four-Circle Goniometers DHS 1100 with graphite dome for high-temperature X-ray studies of polycrystalline samples and thin films from 25 to 1100 °C
  • Domed Hot Stage for Four-Circle Goniometers DHS 1100 with graphite dome for high-temperature X-ray studies of polycrystalline samples and thin films from 25 to 1100 °C
  • Domed Hot Stage for Four-Circle Goniometers DHS 1100 with graphite dome for high-temperature X-ray studies of polycrystalline samples and thin films from 25 to 1100 °C
  • For in-situ high-temperature studies on almost all common four-circle goniometers and many XYZ stages
  • Temperature range from 25 °C to 1100 °C
  • For investigating phase transformations, texture, and internal stress in crystalline materials
Pick your country.
Americas
Brazil
PT
Canada
EN | FR
Colombia
ES
Mexico
ES
Peru
ES
United States
EN
Europe
Austria
DE
Belgium
EN | FR
Croatia
EN
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Africa & Middle East
South Africa
EN
Turkey
TR
United Arab Emirates
EN
Asia-Pacific
Australia
EN
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Philippines
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
EN
Vietnam
EN | VI
If you can't find your country in the list get a quote

DHS 1100 is a heating attachment which is a further development of the well-established DHS 900 Domed Hot Stage. It has an increased temperature range of 25 to 1100 °C. DHS 1100 is small and lightweight and can be mounted on almost all common four-circle goniometers and many XYZ stages. Under its innovative graphite dome, samples can be measured in vacuum, air and various other gases. DHS 1100 is an excellent sample stage for in-situ high-temperature studies of phase transformations, texture, and internal stress in crystalline materials.

Specifications

Operating temperature25 °C to 1100 °C
Temperature measurementPt-10% Rh-Pt thermocouple
AtmospheresVacuum (10 -1 mbar), air,
inert gas,nitrogen
Max. operating pressuremax. 0.3 bar above atmospheric pressure
Possible scattering angle0 to 166° 2Θ
0 to 85° Psi
0 to 360° Phi
Sample holder materialAluminium nitride
Sample diametermax. 25 mm
Dome MaterialGraphite
Transmission
(incident and diffracted rays)
CuKα: 65%
Measure geometryReflection

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more