Rotor 16SOLV HF100

  • Rotor 16SOLV HF100 expands the possibilities of Multiwave PRO for the microwave-assisted digestion and extraction of inorganic and organic samples and is easily upgraded for acid digestion applications by interchanging screw caps.
  • Rotor 16SOLV HF100 expands the possibilities of Multiwave PRO for the microwave-assisted digestion and extraction of inorganic and organic samples and is easily upgraded for acid digestion applications by interchanging screw caps.
  • Rotor for microwave reaction systems
  • Reduces solvent consumption to a minimum
  • Up to 16 extractions simultaneously within 15 to 30 minutes
  • Achieves internal temperatures up to 240 °C
  • Meets requirements of US-EPA and ASTM methods

Rotor 16SOLV HF100 expands the possibilities of Multiwave 5000 for the microwave-assisted extraction of samples and is easily upgraded to accommodate acid digestion applications by interchanging screw caps. Fast, safe, and easy microwave-assisted extraction (MAE) improves both the performance and throughput of HPLC- or GC-based analysis. Extractions of PCBs, PAHs, and hydrocarbons from environmental and food samples deliver perfect results within 15 to 30 minutes, as do derivatization reactions prior to analysis or polymer extractions. The pressure vessel SOLV HF100 is equipped with a ceramic vessel jacket which enables a maximum temperature of 240 °C.

Key features

  • Significant reduction of extraction times
  • Solvent consumption reduced to a minimum
  • Up to 16 extractions simultaneously
  • Meets requirements of US-EPA and ASTM methods
  • Vessels are hermetically sealed and easy to handle
  • The highest safety standards with GS and ETL certificates
  • Temperature- and pressure-controlled procedures in closed vessels – perfect extractions within 15 to 30 minutes
  • Passive heating elements available for non-polar solvents

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Accessories

Accessories

Accessories

Accessories

Not all items are purchasable online in specific countries.

To find out if you can purchase online from your location, check the online availability below.

The gas loading accessory set is a special tool for purging and charging the pressure vessel with gases. It is a helpful tool for performing reactions under inert gas atmosphere or utilizing gaseous reagents. This accessory is suitable for several applications such as microwave oxygen combustion, synthesis, protein hydrolysis and pressure filtration.

Gas Loading Accessory Set

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 104690
Product details
  • Simple purging and charging of pressure vessels with gases
  • Supports reactions under inert gas or with gaseous reagents
  • Handles pressures up to 20 bar with a secure bayonet lock
  • Constructed from durable, chemically resistant PTFE and PEEK materials
The all-purpose calibration unit enables checks and calibrations of all types of temperature sensors used in Multiwave PRO and Multiwave ECO. Calibration of the temperature sensors using the calibration unit maintains the accuracy of the temperature measurement in order to comply with GLP and to extend the lifetime of the reaction vessels.

Calibration Unit

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Calibration of all temperature sensors used in Multiwave 5000
  • Fast sensor accuracy checks and calibration completed in under 20 minutes
  • Calibration data automatically stored in the sensor library for easy access
  • Ensures compliance with GLP and extends the lifetime of reaction vessels
Pressure/temperature sensor accessory for precise reaction control within the reference vessel of Rotor 16MF100 and/or Rotor 16HF100.

p/T Sensor Accessory

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Accessory for Rotor 16MF100 or Rotor 16HF100
  • Precise reaction control within a reference vessel
  • Simultaneous pressure and temperature measurement up to 86 bar (1250 psi) and 280 °C
The pressure sensor accessory allows for precise reaction control within the reference vessel of Rotor 16MF100 or Rotor 16HF100. The pressure data is transferred to the oven via infrared signal. If required, the pressure sensor accessory can be upgraded to a pressure/temperature sensor accessory.

Pressure Sensor Accessory

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Patented pressure sensor accessory for precise reaction control  
  • Infrared data transfer ensures pressure data is transmitted to the oven
  • Capable of measuring pressures up to 86 bar (1,250 psi)
  • Upgrade the pressure sensor accessory for enhanced reaction monitoring
Different racks are available for the adequate storage of the various vessel types and liners of Multiwave PRO as well both vial sizes of Monowave 300. For vessels applicable in the multimode reactors Anton Paar supplies Rack 16, a polyethylene foam block for 16 vessels or liners of Rotor 8 and Rotor 16.

Racks

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Different racks for storing vessels, liners, and vials
  • For Multiwave 5000: Rack 12 for HVT vessels, Rack 10 for SVT vessels, Rack 16 for 16 vessels or liners of Rotor 8 and Rotor 16
  • For Monowave 200/400/450: 24 x 30 mL vials and 40 x 10 mL vials
The cylindrically shaped passive heating elements are made of sintered silicon carbide (SiC). Due to its high microwave absorbance and excellent heat capacity, SiC can be used to efficiently heat low-absorbing solvents (toluene, dioxane, THF…) in a microwave environment.

Passive Heating Elements

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Accessory for microwave reaction systems
  • Made of sintered silicon carbide (SiC) to provide high microwave absorbance and excellent heat capacity
  • Purchase once and reuse again and again
  • Chemically inert and easy to clean
The seal forming device enables the proper pre-forming and safe storage of seals and screw caps of Rotor 8 and 16. One unit has a capacity for 8 caps/seals of different kinds. Storage in this device prolongs the lifetime of the lip-type seals.

Seal Forming Device

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Ensures proper pre-forming and storage of seals and screw caps
  • Holds up to 8 seals/caps of different types for organized storage
  • Effectively prolongs the lifespan of sensitive lip-type seals
  • Time-saving accessory for hassle-free operation

Safety Module SOLV

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Accessory for microwave reaction systems
  • Ensures safe solvent extraction and microwave-assisted synthesis
  • Fail-safe design for maximum safety
  • Can be retrofitted to existing setups

Magnetic Stirrer Device

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 5699
Product details
  • Accessory for microwave reaction systems
  • Stirring improves leaching and extraction processes
  • Supports acid digestion of floating samples
  • Different speeds selectable
  • Retrofittable

Rotor Stand

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Convenient access for easy loading and unloading of vessels
  • Keeps the rotor in a stable position for safe handling
  • Prevents scratching or wear on the rotor's bottom plate
     

More info