Questo è un campo obbligatorio.
Invalid
Numero del pezzo
Errore nella convalida!

Type-Approved Density Meter:
DMA

  • Anton Paar DMA 501 and DMA 1001 density meters side by side, each with a syringe and sample beaker, displaying measurement interfaces.
  • Two lab technicians in a laboratory reviewing Anton Paar-branded folders, with reagent bottles and lab glassware on the bench.
  • A lab technician prepares a sample next to an Anton Paar DMA 4500 M density meter with Xsample 530 sample changer and label printer.
  • Two lab technicians use Anton Paar’s AP Connect software at desktop stations, with a DMA 4500 M density meter visible in the background.
  • A gloved hand operates the touchscreen of an Anton Paar DMA 4500 M density meter with Xsample 530 sample changer in a lab setup.
  • Anton Paar DMA 501 and DMA 1001 density meters side by side, each with a syringe and sample beaker, displaying measurement interfaces.
  • Two lab technicians in a laboratory reviewing Anton Paar-branded folders, with reagent bottles and lab glassware on the bench.
  • A lab technician prepares a sample next to an Anton Paar DMA 4500 M density meter with Xsample 530 sample changer and label printer.
  • +2
Modello:
  • Misuratore di densità a tre cifre omologato per un rapido controllo della qualità in linea
  • Risultati conformi alle norme con un volume minimo del campione
  • Opzioni di riempimento flessibili per una gestione affidabile e semplice
  • Integrazione perfetta di AP Connect per dati sicuri e tracciabili
  • U-View, FillingCheck, U-Pulse per una precisione senza errori

I misuratori di densità e concentrazione omologati di Anton Paar forniscono risultati conformi alle norme, laddove le misurazioni debbano essere sottoposte a ispezioni ufficiali. Progettati per i settori regolamentati, combinano decenni di esperienza applicativa con un'eccezionale precisione, automazione e connettività. Dai beni primari in arrivo fino alla qualità finale del prodotto finito, ottiene dati tracciabili e verificabili in un unico flusso di lavoro altamente efficiente - pronto per l'uso legale per il commercio e per un laboratorio digitale.

Principali caratteristiche

Precisione omologata per la metrologia legale

Affidatevi a risultati di densità e concentrazione pronti per le autorità, i revisori e i clienti. La serie DMA EZ è omologata e progettata specificamente per la metrologia legale, perché le misure siano ottenute con calibrazioni e verifiche ufficiali. In combinazione con la conoscenza del mestiere decennale di Anton Paar, per assicurare massima sicurezza nelle decisioni sul lancio dei prodotti e semplificare la conformità agli standard nazionali e internazionali.

Two lab technicians in a laboratory reviewing Anton Paar-branded folders, with reagent bottles and lab glassware on the bench.

Combinazioni per un sistema di misurazione completo

Per creare il sistema di misura perfetto per le applicazioni di oggi, ed espanderlo domani. Combinando DMA 4101 EZ, 4501 EZ e 5001 EZ con diversi moduli di misurazione Anton Paar, è possibile determinare tutti i parametri rilevanti - come la densità, la concentrazione e altro ancora - in un unico ciclo di misurazione. Questa modularità riduce la manipolazione dei campioni, minimizza l'influenza dell'operatore e accorcia i tempi complessivi di analisi, garantendo al contempo un flusso di lavoro coerente e armonizzato tra diversi prodotti, metodi e sedi di laboratorio.

A lab technician prepares a sample next to an Anton Paar DMA 4500 M density meter with Xsample 530 sample changer and label printer.

Automazione e connettività digitale

Aumenta la produttività e riduce i passaggi manuali con autocampionatori automatizzati che gestiscono le sequenze di riempimento, pulizia e misurazione. Questo migliora la sicurezza e libera il team perché possano concentrarsi su compiti di maggior valore. L'integrazione diretta nel sistema di esecuzione del laboratorio AP Connect porta tutti i risultati in un'unica piattaforma digitale, consentendo una documentazione senza carta, una facile tracciabilità delle misurazioni legali per il commercio e un trasferimento dei dati senza soluzione di continuità ai sistemi LIMS o ERP per una conformità end-to-end.

Two lab technicians use Anton Paar’s AP Connect software at desktop stations, with a DMA 4500 M density meter visible in the background.

U-View e FillingCheck: Misurazioni senza errori

Vedere cosa succede all'interno della cella di misurazione - in tempo reale. U-View fornisce un'immagine live zoomabile che permette agli operatori di verificare visivamente ogni riempimento, mentre FillingCheck rileva automaticamente le microbolle o le condizioni di riempimento improprie. Insieme, riducono in modo significativo gli errori di misurazione e le rielaborazioni, con la possibilità quindi di ottenere risultati sicuri e tracciabili anche con campioni difficili o opachi, un feedback immediato per gli operatori che supporta routine robuste e standard.

A gloved hand operates the touchscreen of an Anton Paar DMA 4500 M density meter with Xsample 530 sample changer in a lab setup.

Specifiche

 DMA 501 EZDMA 1001 EZDMA 4101 EZDMA 4501 EZDMA 5001 EZ
BrevettiEP3012612B1, AT520632B1, US10145771B2AT 516420 B1
Range di misura
Densità da 0,6 g/cm³ a 2 g/cm³
Temperaturada 15°C a 40°C (da 59 °F a 104 °F)da 15°C a 60°C (da 59 °F a 140 °F)da 15°C a 70°C (da 59°F a 158°F)
Pressionepressione atmosferica
Accuratezza*
Densità0,001 g/cm³0,0005 g/cm³ (da 0,6 g/cm³ a 1,5 g/cm³)
0,001 g/cm³ (da 1,5 g/cm³ a 2,0 g/cm³)
0,0005 g/cm³0,0002 g/cm³0,0001 g/cm³
Temperatura0.3 °C (0,5 °F)0,03°C (0.05 °F)**0,02°C (0.04 °F)0,015°C (0.03 °F)0,01°C (0.02 °F)
Ripetibilità (dev. std.)***
Densità0,0002 g/cm³0,00005 g/cm³0,00005 g/cm³0,00005 g/cm³0,000005 g/cm³
Temperatura0,1°C (0.2 °F)0,02°C (0.04 °F)0,02°C (0.04 °F)0,015°C (0.03 °F)0,01°C (0.02 °F)
Riproducibilità (dev. std.)***
Densità0,0004 g/cm³0,00007 g/cm³0,00005 g/cm³0,000005 g/cm³0,000005 g/cm³
Risoluzione digitale
Temperatura0,01°C (0.01 °F)0,01°C (0.01 °F)0,01°C (0.01 °F)0,01°C (0.01 °F)0,001°C (0.001 °F)
Densità0,0001 g/cm³0,00001 g/cm³0,0001 g/cm³0,00001 g/cm³0,000001 g/cm³
Caratteristiche principali
Caratteristiche potentiU-View, FillingCheck, correzione della viscosità a tutto campo
Funzioni specialiRegolazione rapida a punto singolo, scansione della temperatura, sensore di pressione ambientale integrato, monitoraggio delle condizioni (umidità)Scansione della temperatura, sensore di pressione ambiente incorporato, monitoraggio delle condizioni
Opzioni di riempimentoPompa peristaltica, kit di riempimento per campioni pastosiCampionatori automatici
Aggiornamenti e calibrazioniStampanti, calibrazione ISO, sistema di analisi da laboratorio AP Connect
Dati tecnici
Temperatura ambienteDa 5°C a 35°C (da 41°F a 95°F)da 15°C a 35°C
Volume minimo del campione1 mL circa
Materiali a contatto con il campioneVetro borosilicato, PTFE, ETFE
Dimensioni (lungh. x largh. x alt.)375 mm x 280 mm x 180 mm (14,8 pollici x 11,0 pollici x 7,0 pollici)526 mm x 347 mm x 230 mm (20.7 pollici x 13.7 pollici x 9 pollici)
Peso13,5 kg (29,8 libbre)22,04 kg (48,6 libbre)
Alimentazionec.a. da 100 a 240 V; da 47 a 63 Hz; c.c. 24 V, 3AAC da 100 a 240 V, 50/60 Hz, fluttuazione ±10%, 190 VA
Display7", TFT WVGA (800 x 480 Px); touchscreen PCAP10,1”, TFT WXGA (1280 x 800 Px); touchscreen PCAP
ControlliTouchscreen, opzionali: tastiera, mouse e lettore codici a barre
Interfacce di comunicazione1 Ethernet, 3 USB, 1 RS2324 x USB, Ethernet, CAN, RS232
Memoria interna25.000 risultati misurati con immagini della fotocamera60000 valori di misurazione, comprese le immagini della telecamera

Marchi di fabbrica: PEM (017985525), U-View (006834791), FillingCheck (006834725), Thermobalance (006835094)

* Secondo omologazione
** Valido con una temperatura ambiente di ±2°C registrata durante la regolazione
*** In condizioni ideali e per basse densità/viscosità

Standard

Apri tutto
Chiudi tutto

ISO

15212-1

Chinese Pharmacopoeia (ChP)

0601 Relative density determination method

Standard

Apri tutto
Chiudi tutto

ISO

2811-3
12185
15212-1

ASTM

D1250
D1475
D2501
D4052
D4806
D5002
D5931
D6448

DIN

51757

JIS

K 0061
K 2249

IP

365

ABNT

NBR 14065
NBR 15639

US Pharmacopoeia (USP)

841 - Specific Gravity

European Pharmacopoeia (Ph. Eur.)

2.2.5. Relative density

Japanese Pharmacopoeia (JP)

2.56 Determination of Specific Gravity and Density (4. Measurement using an oscillator-type density meter)

Chinese Pharmacopoeia (ChP)

0601 Relative density determination method

RANP

856-2021
864-2021
895-2022
901-2022
903-2022
905-2022
907-2022
909-2022
911-2022
920-2023

Standard

Apri tutto
Chiudi tutto

ISO

2811-3
12185
15212-1
18301

ASTM

D1250
D1475
D2501
D4052
D4806
D5002
D5931
D6448

DIN

51757

JIS

K 0061
K 2249

IP

365

ABNT

NBR 14065
NBR 15639

US Pharmacopoeia (USP)

841 - Specific Gravity

European Pharmacopoeia (Ph. Eur.)

2.2.5. Relative density

Japanese Pharmacopoeia (JP)

2.56 Determination of Specific Gravity and Density (4. Measurement using an oscillator-type density meter)

Chinese Pharmacopoeia (ChP)

0601 Relative density determination method

RANP

856-2021
864-2021
895-2022
901-2022
903-2022
905-2022
907-2022
909-2022
911-2022
920-2023

Standard

Apri tutto
Chiudi tutto

ISO

2811-3
12185
15212-1

ASTM

D1250
D1475
D2501
D4052
D4806
D5002
D5931
D6448

DIN

51757

JIS

K 0061
K 2249

IP

365

ABNT

NBR 14065
NBR 15639

US Pharmacopoeia (USP)

841 - Specific Gravity

European Pharmacopoeia (Ph. Eur.)

2.2.5. Relative density

Japanese Pharmacopoeia (JP)

2.56 Determination of Specific Gravity and Density (4. Measurement using an oscillator-type density meter)

Chinese Pharmacopoeia (ChP)

0601 Relative density determination method

RANP

856-2021
864-2021
895-2022
901-2022
903-2022
905-2022
907-2022
909-2022
911-2022
920-2023

Standard

Apri tutto
Chiudi tutto

ISO

2811-3
12185
15212-1

ASTM

D1250
D1475
D2501
D4052
D4806
D5002
D5931
D6448

DIN

51757

JIS

K 0061
K 2249

IP

365

ABNT

NBR 14065
NBR 15639

US Pharmacopoeia (USP)

841 - Specific Gravity

European Pharmacopoeia (Ph. Eur.)

2.2.5. Relative density

Japanese Pharmacopoeia (JP)

2.56 Determination of Specific Gravity and Density (4. Measurement using an oscillator-type density meter)

Chinese Pharmacopoeia (ChP)

0601 Relative density determination method

RANP

856-2021
864-2021
895-2022
901-2022
903-2022
905-2022
907-2022
909-2022
911-2022
920-2023

Servizio certificato Anton Paar

La qualità Anton Paar nel servizio e nell'assistenza:
  • oltre 350 esperti tecnici certificati direttamente dal produttore a livello globale
  • Assistenza qualificata nella tua lingua
  • Protezione del vostro investimento per l'intero ciclo di vita
  • 3 anni di garanzia
Per saperne di più