Compact Raman Spectrometers:
Cora 5001
- Safe: Laser class 1 for unsurpassed laser safety
- Automated: Autofocus finds the best Raman signal within seconds
- Efficient: Tailored accessories for liquid and solid samples, pills, foils, microscope slides, and petri dishes
Cora 5001 is a Raman analyzer for the quick and reliable identification of substances based on their chemical fingerprint, or for the monitoring of chemical changes. Choose the Fiber model for flexible analysis outside the instrument via a probe or the Direct model which analyzes samples in a closed compartment and is certified as laser class 1 – for ultra-safe use. The guided analysis procedure means Cora 5001 is suitable for operation with only minimal training. The small footprint and battery option make these benchtop Raman instruments versatile tools for analytical tasks in-house or in the field.
Key features
Easy and safe – user guidance and laser Class 1
The handling of the Cora 5001 Raman spectrometers can be learned within minutes, even by inexperienced users. Your new employees or students are able to perform Raman spectroscopy measurements within a very short time – safely. In contrast to many handheld instruments, the Cora 5001 Direct Raman instruments provide extra safety due to their laser Class 1 specification. The laser can only be activated if the measuring chamber is closed and therefore poses no threat to people working in close vicinity to the device.
No sample preparation – accessories to boost efficiency
Regardless of whether the sample is a solid, liquid, or powder, Cora 5001 has the appropriate sample holder for it. You can use vials with various diameters and shapes (round, square, rectangular) or directly analyze solid samples (pills, sample carriers, etc.). Equipped with magnets, the holders are quickly and precisely positioned in the instrument, allowing for immediate sample measurement without refocusing.
Versatility in a nutshell – one instrument, many samples
Do you work with fluorescing substances or many different samples? To cover the widest range of samples and account for possible fluorescence the dual wavelength models provide you with two different excitation wavelengths in one instrument. Each wavelength comes in its own independent optical spectrometer system. Hop from one wavelength to the other at the click of a button without alignment or recalibration and analyze the whole range of substances.
Pharma compliance – with the Anton Paar Spectroscopy Suite
The Anton Paar Spectroscopy Suite takes the complexity out of Raman analysis in the regulated environment. Workflows guide the operator in daily analysis. Lab managers receive assistance in setting up methods and managing reference databases. Comprehensive signing and versioning provide traceability at all times. Audit trail commenting and search functionality are a huge help in audits. And all data is securely retained in an SQL data base.
Autofocus – the strongest signal for reproducible results
Manual focusing onto thin or opaque samples with a weak Raman signal can be tricky. The Cora autofocus feature takes all the complexity out of the measuring routine. It automatically finds the spot with the best Raman signal within seconds so you don’t have to worry about it. This ensures reproducibility and makes the analysis independent of the user.
Technical specifications
Single-wavelength | Dual-wavelength | |||||
Optical specifications | ||||||
Excitation wavelength | 532 nm | 785 nm | 1064 nm | 532 nm and 785 nm | 532 nm and 1064 nm | 785 nm and 1064 nm |
Spectral range | 200 cm-1 to 3500 cm-1 | 100 cm-1 to 2300 cm-1 | 100 cm-1 to 2300 cm-1 | 200 cm-1 to 3500 cm-1 for 532 nm 100 cm-1 to 2300 cm-1 for 785 nm and 1064 nm | ||
Resolution (according to ASTM E2529) | 9 cm-1 to 12 cm-1 | 6 cm-1 to 9 cm-1 | 12 cm-1 to 17 cm-1 | 9 cm-1 to 12 cm-1 for 532 nm 6 cm-1 to 9 cm-1 for 785 nm 12 cm-1 to 17 cm-1 for 1064 nm | ||
Laser power | 50 mW** | 0 mW to 450 mW*, adjustable | 0 mW to 450 mW*, adjustable | 50 mW* for 532 nm 0 mW to 450 mW* for 785 nm and 1064 nm | ||
Spectrograph | f/2; Transmission volume phase grating (VPG) | |||||
Integration time | 0.005 s to 600 s | 0.005 s to 600 s | 0.001 s to 20 s | 0.005 s to 600 s for 532 nm and 785 nm 0.001 s to 20 s for 1064 nm | ||
Wavelength calibration | Automatic via software | |||||
Detector array | 2048 px CCD | 2048 px CCD | 256 px InGaAs | 2048 px CCD for 532 nm and 785 nm 256 px InGaAs for 1064 nm | ||
Laser class | 1 for Direct model 3B for Fiber model | |||||
Physical specifications | ||||||
Dimensions (D x W x H) | 355 mm x 384 mm x 168 mm (14.0 in x 15.1 in x 6.6 in) | |||||
Weight | 9.8 kg | |||||
Operating range | 10 °C to 35 °C (non-condensing) | |||||
Fiber probe dimensions | Cable length: 1.50 m | |||||
Battery (optional) | Lithium-ion | |||||
Battery run time | >1.5 h | |||||
Power supply input | Line power supply input: 115/230 V AC, 50/60 Hz Car power adapter input: 9 V to 32 V DC | |||||
Power consumption | In-line power supply input: max. 100 VA DC input: typical 30 VA (60 VA when optional battery is charged) | |||||
Additional specifications | ||||||
Display | 10-inch touch screen | |||||
Data ports | 4 x USB 2.0, 1 x Ethernet, 1 x CAN out and 1 x USB to PC | |||||
Data export formats | .csv, .txt, .png, .spc,. aps, .pdf | |||||
Internal storage | 8 GB | |||||
Wireless connectivity | Wi-Fi stick (optional) | |||||
Spectral libraries | Factory library, user-built, third-party options | |||||
Security | User roles with customizable permissions, user password logins |
*at sample
**at laser source
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Boosting the Signal with Surface-Enhanced Raman Scattering (SERS) Application Reports
-
Detection of Titanium Dioxide in Food Application Reports
-
E-Book - Field Guide to Battery Materials Characterization – Revised and Updated Application Reports
-
E-Book - Field Guide to Food and Feed Testing Application Reports
-
Identification of Essential Oils Application Reports
-
Identification of Organic Solvents Application Reports
-
Identity Testing of Raw Materials using Raman Spectroscopy: Excipients Application Reports
-
Measurement of Highly Diluted Aqueous Solutions of Ammonium Persulfate Application Reports
-
Measuring Carbon Nanotubes with a Benchtop Raman Spectrometer Application Reports
-
Measuring Graphene with a Benchtop Raman Spectrometer Application Reports
Similar products
Consumables & Accessories
Consumables & Accessories
Accessories
Accessories
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
PH ELECTRODE ENDRESS + HAUSER CPS11 (PRESSURE-RESISTANT)
Cora 5001 Direct | Fiber | Direct for Pharma | Fiber for Pharma
Rheometer-Raman Setup:
MCR Evolution & Cora 5001
Cora 5001 Direct | Fiber | Direct for Pharma | Fiber for Pharma
- Rheology meets Raman spectroscopy
- See how Raman spectra change during rheological investigations
- Better understand changes in chemical functionality and microstructure
WIFI/BLUETOOTH DONGLE
Cora 5001 Direct | Fiber | Direct for Pharma | Fiber for Pharma