inorganic chemicals

Inorganic Chemicals

The vast and diverse range of inorganic chemicals and compounds opens up countless application options and an equally large number of related analysis procedures. Count on Anton Paar’s high-end laboratory and process measurement solutions for material characterization, quality control, sample preparation, synthesis and much more.  Find the measuring instrument that meets your particular needs in the instrument list below – or let us help you find the best solution by contacting us directly.

Get in touch

Anton Paar Products

Your choice: Reset all filters X
Type of operation
Standards
Product Group
Device type
Showing to of

No results found!

Abbemat 3X00 Compact Refractometers

Abbemat Heavy Duty

Abbemat Heavy Duty Line

Abbemat WR/MW, Multi wavelengt refractometer

Abbemat MW Multiwavelengths Refractometer

Abbemat Performance and Performance Plus

Abbemat Performance and Performance Plus Line

Anton Paar Bioindenter (UNHT³ Bio)

Automatisches Verdünnungs- und Dosiersystem DDS

Automatic Dilution and Dosage System: DDS

Ball Mill BM500

Benchtop Heating Stage BTS 500

Benchtop Heating Stages: BTS 150 | BTS 500

Cora 7X00 Raman Spectrometer with Fiber-optic probe

Benchtop Raman spectrometers: Cora 7X00

High-temperature chamber HTK 1200N for combined reflection and transmission XRD studies at high temperatures up to 1200 °C

Capillary Extension: HTK 1200N

Carbo 510 Smart Sensor for CO2 measurement with mPDS 5

Carbo 510 Smart Sensor

Carbo 520 Optical: Sensor module with sapphire and Electronic housing

Carbo 520 Optical

Cryo & Humidity Chamber CHC plus+ is a unique combination of the multi-purpose CHC Cryo & Humidity Chamber and an advanced humidity (RH) generator for the analysis of humidity-dependent and/or temperature-dependent structural changes in materials using X-ray diffraction

Cryo & Humidity Chamber: CHC plus⁺

Density and sound velocity meter: DSA 5000 M

Density meter: DMA™ 501

Density meter: DMA™ 4100 M

Density meter: DMA™ 4500 M

Density meter: DMA™ 5000 M

Dynamic Mechanical Analyzer: MCR 702 MultiDrive

Dynamic shear rheometer measuring head: DSR 502

Furnace Rheometer Systems FRS 1600 and FRS 1800

Handheld density meter: DMA 35 Basic

Handheld Raman spectrometer: Cora 100

Heated sample changer: Xsample 630

HPA-S represents the ultimate performance in wet chemical high pressure digestion sample preparation for AAS, ICP and Voltammetry. The HPA-S acid digestion method is an internationally recognized reference procedure and is in operation as a high-performance routine instrument in numerous laboratories.

High Pressure Digestion: HPA-S High Pressure Asher

Temperature Tribometer

High Temperature Tribometer (THT)

High-precision thermometers: MKT 50 and MKT 10

High-Pressure Chamber HPC 900 - high-pressure and high-temperature chamber for in-situ X-ray diffraction studies of gas-solid interactions

High-Pressure Chamber: HPC 900

High-Temperature Oven Chamber: HTK 1200N with a robust design for in-situ X-ray diffraction studies in different atmospheres up to 1200 °C

High-Temperature Oven Chamber: HTK 1200N

High-Temperature Strip Heater Chambers: HTK 16N | HTK 2000N

HTR Compact: Rheometer autosampler for high sample throughput

HTR: Rheometer automation for high sample throughput and complex sample handling

HTX: Measurement of viscosity, density, concentration of liquids, highly automated and expandable

L-Com 5500: Combined density and sound velocity sensor

L-Dens 2300 density sensor

L-Dens 3300 density sensor

L-Dens 7000 density sensor series

L-Rix 5000/5100/5200 inline refractometer

L-Sonic 5100/L-Sonic 6100 Sound Velocity Sensors

Litesizer™ 100

Litesizer™ 500

Low-Temperature Chamber: TTK 600

Micro Combi Tester (MCT³)

Micro Scratch Tester (MST³)

Microindentation Tester (MHT³)

Microwave digestion system: Multiwave GO Plus

The acid digestion rotor 16HF100 with 16 high pressure vessels is designed for high sample throughput and efficient handling.

Microwave Digestion: Rotor 16HF100

The acid digestion rotor 16MF100 with 16 pressure vessels is designed for high sample throughput and efficient handling.

Microwave Digestion: Rotor 16MF100

Microwave Digestion: Rotor 24HVT80

Rotor 8EVAP is an innovative accessory for microwave evaporation with the modular Multiwave PRO microwave sample preparation system. It greatly simplifies and accelerates the microwave-assisted evaporation of acids and concentration of aqueous sample solutions in 8 vessels simultaneously.

Microwave Evaporation: Rotor 8EVAP

Rotor 16SOLV HF100 expands the possibilities of Multiwave PRO for the microwave-assisted digestion and extraction of inorganic and organic samples and is easily upgraded for acid digestion applications by interchanging screw caps.

Microwave extraction: Rotor 16SOLV HF100

Rotor 16SOLV MF100 expands the possibilities of Multiwave PRO for the microwave-assisted digestion and extraction of inorganic and organic samples and is easily upgraded for acid digestion applications by interchanging screw caps.

Microwave extraction: Rotor 16SOLV MF100

Based on a revolutionary new technique, the all-new Masterwave BTR benchtop reactor for the first time transfers microwave synthesis to the kilolab. Productivity in your lab is considerably increased up to kilogram amounts per day. The benchtop reactor’s magnetically driven paddle stirrer provides independent stirring regimes for individual content. Due its rising-sensor temperature measurement technique, Masterwave BTR features the high temperature accuracy required for direct method transfer from any smaller microwave device.

Microwave Synthesis in the Kilolab: Masterwave BTR

Microwave Synthesis: Monowave 400/200

Rotor 1DRY is the ideal accessory for efficient handling of samples prior to digestion. Microwave-assisted drying takes a quarter of the time required by conventional methods, without carbonization or contamination of samples.

Microwave-assisted Drying: Rotor 1DRY

Nano scratch tester: NST³

Nanoindentation tester: NHT³

Oxy 510 Inline Oxygen Sensor

Pressure/temperature sensor accessory for precise reaction control within the reference vessel of Rotor 16MF100 and/or Rotor 16HF100.

p/T Sensor Accessory

PC-controllable Alignment Stage

pH ME Beverage Measuring Module and pH ME Measuring Module

Cora 5X00 Raman Spectrometer

Portable benchtop Raman spectrometers: Cora 5X00

Portable density meter: DMA 35

The pressure sensor accessory allows for precise reaction control within the reference vessel of Rotor 16MF100 or Rotor 16HF100. The pressure data is transferred to the oven via infrared signal. If required, the pressure sensor accessory can be upgraded to a pressure/temperature sensor accessory.

Pressure Sensor Accessory

Reactor Chamber: XRK 900

Reactor Chamber: XRK 900

Revetest® Scratch Tester (RST³)

Rheometer: MCR 102, MCR 302, MCR 502

Rolling-ball viscometer Lovis 2000 M/ME

The RheolabQC is the quality control rheometer from Anton Paar. RheolabQC with temperature device C-PTD 180/AIR/QC and with Flexible Cup Holder.

Rotational Rheometer: RheolabQC

The high-throughput rotor 4x20MGC for parallel processing of smallest sample quantities in biotechnology, medicinal and forensic chemistry comprises up to 80 disposable standard GC/HPLC glass vials placed in silicon carbide (SiC) plates with a compact 5x4 matrix.

Rotor 4x20MGC

The Rotor 4x24MG5 is specially designed for hit-to-lead generation in gram scale and parallel method optimization in microwave synthesis. Its reliable setup features 96 disposable glass vials arranged in ANSI format silicon carbide blocks with a convenient 6x4 matrix for reaction conditions up to 200 °C and 20 bar.

Rotor 4X24MG5

Perfect results with automatic cleaning and needle washing using up to three cleaning solvents.

Sample changer: Xsample 530

Software for particle analysis: Kalliope™

Top View mounted T-probe with Rotor 8N of Multiwave PRO.

T-probe

Ultra nanoindentation tester: UNHT³

Showing to of

Anton Paar Applications

Can’t Etch This! Accurate Inline Process Concentration of Corrosive Acids

Can’t Etch This! Accurate Inline Process Concentration of Corrosive Acids

Relevant for acids, batteries, desiccants, dyes, explosives, fabrics, fertilizer, insecticides, picklingbBaths, plastics, plating baths, propellants, surfactants, titanium oxide, wood preservatives, and many more

Safe and Accurate Inline Sulfuric Acid Measurement Improves Quality and Production

Safe and Accurate Inline Sulfuric Acid Measurement Improves Quality and Production

Relevant for fertilizers, acid production, sulfates, sulfonates, glass, detergents, batteries, Pickling baths, and many more

Concentration Measurement of Sodium Hydroxide Solutions by Refractive Index

Concentration Measurement of Sodium Hydroxide Solutions by Refractive Index

The concentration of sodium hydroxide in water can be easily and quickly determined by refractive index measurement.

Improve Digestion Quality and Save Money – Microwave Digestion rules out Open Digestion

Improve Digestion Quality and Save Money – Microwave Digestion rules out Open Digestion

Reliable elemental analysis results need robust sample preparation to destroy sample matrices or to separate matrix from analytes. The sample preparation step is by far the most error-prone and critical step of the analytical procedure.

Refractive Index Measurement of Ionic Liquids

Refractive Index Measurement of Ionic Liquids

Ionic liquids are special designer solvents as they are nonvolatile and liquid at ambient temperature, leading to a wide range of applications. Their refractive index helps to control the quality and also to characterize them.

Have a Good Trip

Have a Good Trip

Refractometers are widely used in the automotive industry, e.g. to control the quality of oils, chemical liquids and solids such as plastics and glasses.

Mesoporous thin films - Investigating the structure of multi-layered films by GISAXS

Mesoporous thin films - Investigating the structure of multi-layered films by GISAXS

Single- and double-layered mesoporous thin films have been analyzed by GISAXS for their structural properties using the SAXSpoint system.

Can I Monitor the Composition of my Pickling Bath?

Can I Monitor the Composition of my Pickling Bath?

Relevant for steel, aluminium, semiconductors, electronics

How can the Phosphoric Acid Production be Monitored?

How can the Phosphoric Acid Production be Monitored?

Relevant for phosphoric acid production, hydrogen halide production, fuel cells, etching

Determination of Oil Circulation Ratio in Cooling Systems

Determination of Oil Circulation Ratio in Cooling Systems

Relevant for air-conditioning manufacturer, compressor manufacturer, research institutes, test bench engineering

Characterization of the scratch resistance of ceramic tiles

Characterization of the scratch resistance of ceramic tiles

The influence of Surface Roughness on Instrumented Indentation Testing (IIT)

The influence of Surface Roughness on Instrumented Indentation Testing (IIT)

In-Situ observation of the scratch/indentation true contact area to provide analysis without being model-dependent

In-Situ observation of the scratch/indentation true contact area to provide analysis without being model-dependent

Nanoindentation and Nanoscratch of Oxide Coatings on Thin Film Polymer Substrates

Nanoindentation and Nanoscratch of Oxide Coatings on Thin Film Polymer Substrates

Nanoindentation approach to mechanical testing of extremely soft materials

Nanoindentation approach to mechanical testing of extremely soft materials

Nanotribological properties of Diamond like carbon thin flexible films on ACM rubber

Nanotribological properties of Diamond like carbon thin flexible films on ACM rubber

Spherical Nanoindentation of Polyacrylamide Hydrogels using the Bioindenter (BHT)

Spherical Nanoindentation of Polyacrylamide Hydrogels using the Bioindenter (BHT)

The Ultra Nanoindentation Tester: New generation of thermal drift free indentation

The Ultra Nanoindentation Tester: New generation of thermal drift free indentation

Identifying three different particle sizes in one sample with DLS

Identifying three different particle sizes in one sample with DLS

Particle suspensions often contain more than one size of particle. However, many particle analyzers cannot resolve particle mixtures, instead they detect an average of all sizes. The Litesizer™ 500 can detect three sizes in one sample.

Nanoparticles for Ceramics: Size, Stability & pH

Nanoparticles for Ceramics: Size, Stability & pH

In nanoparticle suspensions that will be used in ceramics, particle size and stability are of vital importance. Suspension stability is essential to ensure that the particles to stay in suspension, and maintain constant particle size.

Temperature-dependent GISAXS studies on thin films

Temperature-dependent GISAXS studies on thin films

The temperature-induced decomposition of a thin film structure has been studied using the SAXSpoint system with the new temperature-controlled GISAXS stage.

An insight into the Structure of Copolymer Surfactants

An insight into the Structure of Copolymer Surfactants

The structure of inhomogeneous (core-shell) nanoparticles was studied with the SAXSpoint system. The internal structure of Pluronic P123 micelles in water was determined by calculating the radial electron density profile.

Collagen - A Validation Sample for SAXS Systems

Collagen - A Validation Sample for SAXS Systems

The performance of the SAXSpoint 2.0 system is evaluated by measurements of tendon collagen. SAXSpoint 2.0 produces data with excellent resolution in the entire angular range and delivers true 2D SWAXS images.

SAXSpoint with MetalJet Source

SAXSpoint with MetalJet Source

SAXSpoint now integrates the high-brightness MetalJet X-ray source enabling ultra-fast SAXS measurements in the laboratory.

Safer and More Accurate Ammonia Measurement

Safer and More Accurate Ammonia Measurement

Relevant for production of fertilizers, refrigerants, nitrogenous production, cleaning agents

In-situ GISAXS heating experiments on self-assembled Gold nanoparticles

In-situ GISAXS heating experiments on self-assembled Gold nanoparticles

Thermal morphology changes of self-assembled Gold nanoparticles have been studied using the SAXSpoint system with the temperature controlled GISAXS stage.