External Measuring Cell:
DMA HPM
- Density measurement at sample pressures up to 1400 bar and temperatures from -10 °C to 200 °C
- Ideal for PVT analysis and enhanced oil recovery (EOR) experiments
- Remote data reading via evaluation unit mPDS 5
The External Measuring Cell DMA HPM measures density at sample pressures up to 1400 bar and temperatures from -10 up to 200 °C. Connect an mPDS 5 evaluation unit to control DMA HPM and read out the measurement data. To thermostat DMA HPM use a climatic chamber, an oven or a heating or cooling bath.
Key features
Measure safely at high pressures and high temperatures
- No-hassle measurement at high temperatures and/or pressures
- Only 2 mL sample required
- Locate the mPDS 5 evaluation unit up to 100 m from DMA HPM
- Ideal for PVT analysis and enhanced oil recovery (EOR) experiments
Memory for 999 adjustments
- Store up to 999 adjustments in mPDS 5
- Easy to select between single-point adjustment or wide range adjustment
- Use wide range adjustment to measure the sample density over wide temperature and pressure ranges
Technical specifications
Measuring range | |||
---|---|---|---|
Density | 0 to 3 g/cm3 | ||
Pressure | 0 to 1400 bar (0 to 20,300 psi) | ||
Temperature | -10 to +200 °C (14 to 392 °F) | ||
Accuracy | |||
Density | Up to 0.0001 g/cm3 | ||
Repeatability s.d. | |||
Density | Up to 0.00001 g/cm3 | ||
Digital Resolution | |||
Density | 0.00001 g/cm3 | ||
Additional information | |||
Cell material | Hastelloy C-276 | ||
Volume of the measuring cell | approx. 2 mL | ||
Dimensions (L x W x H) DMA HPM Interface module | 210 x 78 x 86 mm (8.3 x 3.1 x 3.4 inches) 220 x 120 x 80 mm (8.7 x 4.7 x 3.1 inches) | ||
Weight DMA HPM Interface module | 8.3 kg (18.3 lbs) 1.5 kg (3.3 lbs) | ||
Connections | Pressure fittings for metal tubes with 1/4" outer diameter |
Standards
European Pharmacopoeia (Ph. Eur.)
US Pharmacopoeia (USP)
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Cleaning recommendations for Anton Paar DMA instruments Application Reports
-
Enhanced oil recovery (EOR) Application Reports
-
Unveil the secret of crude oil reservoirs with DMA HPM Application Reports
Consumables
Consumables
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
RUBBER FOOT COMPLETE
GLAND NUT FOR DMA HPM
COLLAR FOR DMA HPM
CONNECTION TUBE WITH THREAD
UER ADAPTER 1400 BAR
SYRINGE 5 mL LUER (WITHOUT SEAL)
HOSE 7x10 SILICONE
SYRINGES 5 ml LUER (100 pcs.)