Rolling-Ball Viscometer:
Lovis 2000 M/ME
- Measures dynamic viscosity and relative viscosity from only 100 µL of sample
- Powerful polymer software automatically delivers intrinsic viscosity, molar mass, K‑value, and more
- Referenced in US and European Pharmacopoeia
Lovis 2000 M/ME is a rolling-ball viscometer which measures the rolling time of a ball through transparent and opaque liquids based on Hoeppler's falling ball principle. The instrument is mainly used for viscosity measurements of low viscous liquids for R&D applications, in the pharmaceutical and chemical industries. A measurement with Lovis 2000 M/ME can yield dynamic viscosity, intrinsic viscosity, molar mass of a polymer and more.
Key features
For R&D
- Small sample amount (starting from 100 μL)
- Sample recovery
- Wide temperature range (5 °C to 100 °C / 41 °F to 212 °F without counter-cooling); measurements with counter-cooling even down to -30 °C (-22 °F)
- Wide viscosity range (0.3 mPa.s to 10,000 mPa.s)
- High accuracy
- Variable inclination angle for testing shear-dependent flow behavior
For pharmaceutical and medical labs
- Included in US and European Pharmacopoeia
- Pharma qualification packages available
- Optional modular combination with Anton Paar instruments for measuring density, refractive index, turbidity and pH value
- Flow-through filling for large sample throughput
For the chemical industry
- Hermetically closed system for volatile or toxic samples
- High chemical resistance (borosilicate glass or PCTFE)
- Special polymer measuring and evaluation features
- Automatic filling using autosampler
- Testing of opaque samples
Technical specifications
Viscosity | |||
---|---|---|---|
Viscosity range | 0.3 mPa.s to 10,000 mPa.s | ||
Repeatability s.d. | up to 0.1 % 1) | ||
Accuracy | up to 0.5 % 1) 2) | ||
Temperature | |||
Temperature range | 5 °C to 100 °C (41 °F to 212 °F) without counter-cooling Down to -30 °C (-22 °F) with counter-cooling | ||
Repeatability s.d. | 0.005 °C | ||
Accuracy | 0.02 °C | ||
Measuring time | |||
Resolution | 0.001 s | ||
Accuracy | 0.05 % | ||
Further specifications | |||
Test duration | minimal 30 s, typical 3 min | ||
Sample volume | 0.1 mL to 0.8 mL | ||
Inclination | 15° to 80° in 1° steps | ||
Repeatability s.d. | 0.02 ° | ||
Accuracy | 0.1 ° | ||
Shear rate | 0.5 s-1 to 1000 s-1 influenced by capillary size and inclination | ||
1) depends on sample type and measuring settings, without changing the ball | |||
2) for the range in which the calibration constant was determined, not including uncertainty of reference standards |
Standards
ASBC
DIN
DIN EN ISO
European Pharmacopoeia (Ph. Eur.)
US Pharmacopoeia (USP)
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Beverage | Beer | Complete your Beer Analysis Application Reports
-
Biopolymers | Quality Control of Biopolymers Application Reports
-
Chemicals | Quality control of raw materials for epoxy resin production Application Reports
-
Chemicals | Viscosity and Density Measurement of Ionic Liquids/Solvent Mixtures Application Reports
-
E-Book - Field Guide to Battery Materials Characterization – Revised and Updated Application Reports
-
Fast and Reliable Density and Viscosity Measurement of Wort Application Reports
-
How to develop a method for measurements with Lovis 2000 M/ME Application Reports
-
Medical | Lovis 2000 M/ME and DMA 4500 M: Viscosity Measurement of Whole Blood Application Reports
-
Micelle Characterization by DLS: Bringing Viscosity into the Equation Application Reports
-
Pharma, Cosmetics | Lovis 2000 M/ME: Intrinsic Viscosity of Hyaluronic Acid Application Reports
-
Pharma, Food, Oil, Fuel | Comparison Lovis 2000 M/ME vs Ubbelohde Application Reports
-
Pharma, Medical | Lovis 2000 M/ME for Low Volume Applications Application Reports
-
Polymers | Intrinsic Viscosity Measurements for Quality Control of PET Application Reports
-
Polymers | Measuring Intrinsic Viscosity for Optimized Plastic Processing Application Reports
-
Polymers | Reduced Viscosity as Quality Control Parameter for Polyamides Application Reports
Consumables, Accessories & Software
Consumables, Accessories & Software
Accessories & Software
Accessories & Software
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
LUER PLUG W/O BORE (10 pcs.)
LOVIS MANUAL FILLING SET 2.5
CAPILLARY LOVIS 1.8 SHORT UNCALIBRATED
CAPILLARY LOVIS 2.5 SHORT UNCALIBRATED
CAPILLARY PLUG HOLLOW 2.5 (20 pcs.)
GLASS/PTFE SYRINGE 10 mL LUER LOCK
HOLLOW NEEDLE 50x0.7 LUER LOCK (12 PCS.) BLUNT SS304/1.4301
HOLLOW NEEDLE 50x1.2 LUER LOCK (12 PCS.) BLUNT SS304/1.4301
LOVIS LOW VOLUME FILLING SET 1.8 SHORT
LOVIS LOW VOLUME FILLING SET 2.5 SHORT
Brush 23,5x12xØ3,0 fine (10 pcs.)
HOSE 530x3x2 FEP 2x1/4"-28 UNF "C"
RUBBER FOOT COMPLETE
CABLE TIE HEAT-RESISTANT 100 pcs
CAN INTERFACE CABLE 0.6m
HOSE 8x12 PERBUNAN
HOSE 155x3x2 FEP 2x1/4"-28 UNF
PROTECTION FOILS FOR TOUCH-SCREEN (3 PCS)
PROTECTIVE COVER FRONT (3 PCS) FOR 6.4" DISPLAY
INJECTION ADAPTER SOUND UNF ¼"
INJECTION ADAPTER FITTING SOUND
HOSE 120x3x2 PTFE 2x1/4"-28 UNF
CAN/DEVICENET TERMINATING RESISTOR 5-POLES
HOSE 3x5 VITON
INSULATION HOSE ARMAFLEX D12/25
DRIP PLATE MODULE HOUSING LOVIS ME
HOSE SET LOVIS + DMA + XS 22/320 122/520
HOSE 350x3x2 FEP 2x1/4"-28 UNF
HOSE 600x3x2 FEP 2x1/4"-28 UNF
HOSE 220x3x2 FEP 2x1/4"-28 UNF "CC"
WASTE BOTTLE SVM
HOSE 650x3x2 FEP 1x1/4"-28 UNF "AD"
SET OF BALLS 1.5 mm (300 pcs.)
FILLING ADAPTER LUER FEMALE
O-RING 5x1.5 FPM 75 VITON EXTREME (10 pcs.)
FILLING AND CLEANING ADAPTER LUER MALE
LOVIS FLOW-THROUGH FILLING SET 1.59
CAPILLARY LOVIS 2.5 UNCALIBRATED
BALL DISPENSER 1.5 mm
O-RING 5x1.5 KALREZ SPECTRUM 6375
BRUSH 175x25x2.6 GOAT HAIR (5 pcs.)
ACCESSORY KIT COMPLETE - LOVIS
LOVIS MANUAL FILLING SET 1.59
CAPILLARY LOVIS 1.62 PCTFE UNCALIBRATED
SET OF BALLS 1.5 mm 4 µ GOLD (300 pcs.)
LOVIS FLOW-THROUGH FILLING SET 1.8
SCREW CAP FRONT SIDE - CLOSED
SCREW CAP BACK SIDE - CLOSED
CAPILLARY PLUG HOLLOW 1.59 (20 pcs.)
SCREW CAP FRONT SIDE - OPEN
LOVIS FLOW-THROUGH FILL SET 1.62 PCTFE
SYRINGES 20 ml LUER (100 pcs.)
CAPILLARY PLUG 1.59 (20 pcs.)
SYRINGES 1 ml LUER (100 PCS) For filling quartz cuvettes.
HOOK FOR O-RING REMOVAL
LOVIS FLOW-THROUGH FILLING SET 2.5
NHÍP NHỰA
FUNNEL FOR 1.5 mm BALL - LOVIS
LUER PLUG WITH BORE (10 pcs.)
LOVIS MANUAL FILLING SET 1.8
CAPILLARY PLUG 1.8 (20 pcs.)
CAPILLARY PLUG HOLLOW 1.8 (20 pcs.)
GLASS/PTFE SYRINGE 250 µL LUER LOCK
FILLING ADAPTER UNF BACK SIDE COMPLETE
CAPILLARY PLUG 2.5 (20 pcs.)
SCREW CAP BACK SIDE - OPEN
FILLING ADAPTER UNF
HOSE 3.2x6.4 mm TYGON A-60-G, BLACK (FORMERLY:
NORPRENE A-60-G)
ANGULAR SCREWDRIVER TORX T20
CHECK VALVE SILICONE HOSE 3X5
"HOSE 300x3x2 PTFE ""AA"""
SYRINGES 2 ml LUER (100 pcs.)
SYRINGES 10 ml LUER (100 pcs.)
SYRINGES 5 ml LUER (100 pcs.)
PH ELECTRODE HAMILTON PH=0-14 0-80°
HOSE 750x3x2 PTFE 1x1/4"-28 UNF "AD"
TEST TUBE RACK 12 ml / 60 POSITIONS
HOSE 3x5 SILICONE
HOSE 2x4 SILICONE
HOSE 2x4 VITON
PRINTER PAPER 57x30 STANDARD
PRINTER CONNECTION CABLE
ADAPTER LUER 1/4" UNF
HOSE 1.6x3.2 TYGON
TUBE d=2.1 D=2.4 L=20 1.4571
HOSE 190x3x2 PTFE 1x1/4"-28 UNF
PRINTER PAPER FOR EPSON TM-U220
RIBBON CARTRIDGE FOR EPSON PRINTER TM-U220
VISCOSITY STANDARD ANTON PAAR S3 (L) 100 ml - 3.7 / 2.3 / 0.9 mPa.s
Recommended for DIN/SSA/UL spindles
VISCOSITY STANDARD ANTON PAAR N7.5 (M) 100 ml - 10 / 5.4 / 1.6 mPa.s
Recommended for DIN/SSA/UL spindles
VISCOSITY STANDARD ANTON PAAR N26 (C) 100 ml - 50 / 21 / 4.2 mPa.s
Recommended for DIN/SSA/UL spindles
VISCOSITY STANDARD ANTON PAAR N415 (H) 100 ml - 1100 / 330 / 32 mPa.sc
Recommended for DIN/SSA/UL spindles
VISCOSITY STANDARD H2O 100 ml CERTIFIED
INJECTION ADAPTER UNF 1/4"
INJECTION ADAPTER FITTING WITH METAL TUBE
VISCOSITY STANDARD ANTON PAAR S3 (L) 500 ml - 3.7 / 2.3 / 0.9 mPa.s
VISCOSITY STANDARD ANTON PAAR N7.5 (M) 500 ml - 10 / 5.4 / 1.6 mPa.s
VISCOSITY STANDARD ANTON PAAR N26 (C) 500 ml - 50 / 21 / 4.2 mPa.s
VISCOSITY STANDARD ANTON PAAR N415 (H) 500 ml - 1100 / 330 / 32 mPa.s
VISCOSITY STANDARD ANTON PAAR S6 500 ml - 8.8 / 4.7 / 1.5 mPa.s
VISCOSITY STANDARD ANTON PAAR N14 500 ml - 25 / 12 / 2.7 mPa.s
VISCOSITY STANDARD ANTON PAAR N75 500 ml - 164 / 61 / 8.8 mPa.s
VISCOSITY STANDARD ANTON PAAR N1400 500 ml - 5000 / 1200 / 74 mPa.s
VISCOSITY STANDARD ANTON PAAR N4000 500 ml - 16000 / 2900 / 100 mPa.s
VISCOSITY STANDARD ANTON PAAR N100 500 ml - 280 / 86 / 9.7 mPa.s
SELF-LOCKING COUPLING 9 mm
CAPILLARY LOVIS 1.59 UNCALIBRATED
CAPILLARY LOVIS 1.8 UNCALIBRATED
VISCOSITY STANDARD ANTON PAAR N100 100 ml - 280 / 86 / 9.7 mPa.s
280 / 86 / 9.7 mPa.s
PH ELECTRODE HAMILTON FOODTRODE
BRUSH 175x25x2.7 NYLON 0.06 (5 pcs.)
VISCOSITY STANDARD ANTON PAAR N1400 100 ml - 5000 / 1200 / 74 mPa.s
HOSE CLAMP DMIN 5.8 DMAX 6.5
MALE LUER PLUG
ADAPTER LUER CONE
HOSE 3.2x6.4 mm TYGON CHEMICAL (FORMERLY:
NORPRENE CHEMICAL)
HOSE 2.5 x 4.5 NOVOPRENE