Combined Rheology and SAXS Setup:
RheoSAXS Module
- Study structural and rheological properties simultaneously
- Measure parallel or perpendicular to flow direction
- All existing SAXSpoint instruments can be upgraded with this module
The lab-scale RheoSAXS system is the clever combination of two world-class Anton Paar instruments: The renowned SAXSpoint 5.0 delivers brilliant results on the nanoscale. Combined with the DSR 502 dynamic shear rheometer (based on the MCR rheometers) this makes RheoSAXS – the first commercially available setup for studying structural and rheological properties simultaneously in one setup in your lab. RheoSAXS resolves the combined information of your sample within minutes.
Key features
![New opportunities for combined RheoSAXS measurements New opportunities for combined RheoSAXS measurements](https://www.anton-paar.com/fileadmin/_processed_/3/8/csm_1-RheoSAXS-06_6fe2b0f16a.jpg)
New opportunities for combined RheoSAXS measurements
- 10 nNm minimum torque in rotation and 2 nNm minimum torque in oscillation allow measurement of low-viscosity dilute suspensions.
- Easy to handle thanks to the quick coupling mechanism of the upper geometry
- Marks on the flange between DSR 502 and the X-ray measuring chamber make changing from axial to tangential setup easy.
![X-ray-transparent RheoSAXS measuring cell X-ray-transparent RheoSAXS measuring cell](https://www.anton-paar.com/fileadmin/_processed_/b/5/csm_2-RheoSAXS-04_1457eca091.jpg)
X-ray-transparent RheoSAXS measuring cell
- Measure parallel or perpendicular to flow direction to obtain the orientation of the sample distribution with respect to flow direction.
- Cylindrical measuring geometry corresponding to DIN 53019, gap size 1 mm, made of X-ray-transparent polycarbonate
- Filling volume: 8 mL
- Temperature control in the range from -10 °C to 90 °C
![Upgrade of all existing SAXSpoint 5.0 systems anytime Upgrade of all existing SAXSpoint 5.0 systems anytime](https://www.anton-paar.com/fileadmin/_processed_/9/5/csm_3-RheoSAXS-03_35d550219f.jpg)
Upgrade of all existing SAXSpoint 5.0 systems anytime
- All existing SAXSpoint 5.0 systems in the field can be equipped for combined RheoSAXS measurements.
- The DSR 502 measuring head is integrated in SAXSpoint 5.0 and the system can be aligned using the SAXSdrive™ software.
- Use SAXSanalysis™ to analyze the scattering data and RheoCompass™ on its own to analyze the rheological data.
Technical specifications
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Combined Rheo-SAXS Investigations using a Laboratory SAXS System Application Reports
-
Laboratory Rheo-SAXS Studies of Non-ionic Surfactants Application Reports
-
White Paper: Small-angle X-ray Scattering in Materials Science Application Reports
-
Instruments - MCRxx2 Evolution series Brochures
-
RheoSAXS Brochures
-
SAXS Sample stages and holders Brochures