This is a required field.
Invalid
Part number
Error in validation!

Sample Changer:
Xsample 330

  • media
  • media
  • +3
  • The single sample changer for a wide range of samples
  • Prevents sample carry-over with automatic rinsing and drying after each sample
  • Highly resistant wetted parts for handling aggressive samples
Pick your country.
Americas
Brazil
PT
Canada
EN | FR
Colombia
ES
Mexico
ES
Peru
ES
United States
EN
Europe
Austria
DE
Belgium
EN | FR
Croatia
EN
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Africa & Middle East
South Africa
EN
Turkey
TR
United Arab Emirates
EN
Asia-Pacific
Australia
EN
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Philippines
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
EN
Vietnam
EN | VI
If you can't find your country in the list get a quote

The new industrial grade peristaltic pump in combination with automatic cleaning makes Xsample 330 perfectly suitable for measuring single low-viscosity samples with widely different properties in direct succession. Once measured, the sample is drained or recovered and the system is automatically cleaned with up to two cleaning agents. A drying step is performed by the operator to perfectly prepare the measurement cell(s) for the next sample.

Key features

Automatic cleaning

  • Automatic rinsing and drying after each sample for perfect preparation of the system
  • Up to two different cleaning agents can be used in any order for an individual cleaning procedure.
  • Advanced settings for cleaning procedures to increase measuring performance

For a wide range of samples

  • Filling with peristaltic pump covers a wide range of different sample viscosities up to 3,000 m.Pas
  • All wetted parts of Xsample 330 (high resistance) are made of durable materials for aggressive samples, such as phosphoric acid or trichloroacetic acid
  • Adjustable filling modes for different types of samples enable perfect measuring results

Highly efficient sample handling and easy operation

  • Depending on the system size, only a minimum amount of sample volume is needed to perform a measurement
  • Easy operation by an integrated user interface on the master instrument
  • Straightforward measurements of different sample viscosities due to a sensor-controlled stop of the filling procedure
  • Automatic sample recovery returns expensive or hazardous samples back to their vials

Specifications

Viscosity rangeup to 3,000 mPa•s at ambient and measuring temperature¹
Filling mode

with peristaltic pump:

  • Suction mode in one direction
  • Suction mode with pumping back and forth at the beginning
Typical time for filling and measuring cycle2 to 5 minutes
Minimum sample volumeapprox. 10 mL to 20 mL
Compressed air supplymax. 2 bar (29 psi) relative
Quality of air necessaryClass 3 according to ISO 8573-1:
max. particle size: 5 μm
max. pressure dew point: –20 °C (–4 °F)
max. oil content: 1 mg/m³
Environmental conditions (EN 61010)indoor use only
Operating temperature+15 °C to +35 °C (+59 °F to +95 °F)
Pollution degree2
Over voltage categoryII
Altitudemax. 3,000 m (9,840 ft)
Power supplysupplied by the master instrument
AC power supply voltage according to technical data plate at the rear of the master instrument (protective grounding required)
Dimensions excl. master instrument (L x W x H)205 mm x 148 mm x 205 mm (8.1 in x 5.8 in x 8.1 in)
Weight excl. master instrumentapprox. 3.8 kg (8.4 lbs)

¹ Recommended for samples with a viscosity up to 500 mPa•s at ambient and measuring temperature. For samples with a viscosity higher than 500 mPa•s at ambient and measuring temperature, bubbles may occur during filling.

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Compatible instruments