Temperature Control Solutions for ViscoQC:
Temperature Device
- For ViscoQC 100/300; viscometers and temperature device from a single source
- Air cooling ensures small footprint, and reduces maintenance costs
- Exact sample temperature control of, e.g. chocolate, adhesive
- For routine QC applications from +15 °C to +80 °C (±0.1 °C)
Save time with supremely accurate sample temperature control from -45 °C to +175 °C, and unbeatable heating (typical: 9.4 K/min) and cooling (typical: 2.3 K/min) rates, delivered by the high-performance Peltier PTD 175 temperature device. Enjoy super-precise sample temperature control (±0.1 °C) at a specific temperature in the range of +15 °C to +80 °C with PTD 80. Both instruments are fully controlled by the ViscoQC user interface. PTD 175 supports solely ViscoQC 300; PTD 80 can be used with both, ViscoQC 100 and ViscoQC 300. Both devices have the unique T-Ready™ function telling users when the sample has reached the set temperature. Standardized test methods bring further ease of use.
Key features
Wide-range Peltier device PTD 175 for ViscoQC 300
- Ready to use right out of the box
- Small footprint: saves you space in the lab
- Super-convenient control through ViscoQC 300’s 7” touchscreen
- Controls sample temperature of DIN/SSA/UL/L1D22/4B2 measuring systems
- Unique T-Ready™ function signals when sample has reached set temperature
- Most precise viscosity determination with a temperature accuracy of ±0.1 °C
- Built-in Pt100 sensor reliably monitors the sample temperature
Peltier device PTD 80 for ViscoQC 100/300
- Ready to use right out of the box
- Small footprint: saves you space in the lab
- Eliminates cable clutter: Power supplied by ViscoQC
- Super-convenient control through user interface of ViscoQC
- Controls sample temperature of DIN/SSA measuring systems
- Unique T-Ready™ function signals when sample has reached set temperature
- Most precise viscosity determination with a temperature accuracy of ±0.1 °C
Water bath Julabo Corio for ViscoQC 100/300
- Small footprint: saves you space in the lab
- Controls sample temperature of 600 mL beakers
- Monitor sample temperature with optional temperature sensor
- Optional tap water coil for operation at ambient conditions
Technical specifications
PTD 175 | PTD 80 | Water bath | |
Temperature Range [°C] | -45 to +175 | +15 to +80 | ambient to +100 |
Supported viscometer(s) | ViscoQC 300 | ViscoQC 100/300 | ViscoQC 100/300 |
Supported measuring systems | Concentric cylinders, double-gap, ultra low viscosity adapter, small sample adapter, insulated 4B2, L1D22 | Concentric cylinders, double-gap, small sample adapter | L/RH, T-bar, and vane spindles in 600 mL beakers |
Cooling liquid | None Air counter-cooled | None Air counter-cooled | Water |
External power supply | Yes | No, through ViscoQC | Yes |
Standards
AASHTO
ASTM
DIN
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Adhesives | Measurement of Hot Melt Adhesives According to ASTM D3236 Application Reports
-
Asphalt, Bitumen | Measurement of bitumen according to ASTM D4402 / AASHTO T316 Application Reports
Compatible instruments
Similar products
Consumables
Consumables
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
Spacer Ring UL26
Temperature Device PTD 80
DISPOSABLE MEASURING CUP D22 1 pack = 100 pcs. (blank aluminium)
Temperature Device PTD 175
For measuring system 4B2 insulated and L1D22.
VITON O-RING FOR DIN/SC4 SYSTEMS
Temperature Device PTD 80 | PTD 175
O-ring sitting on the bottom plug of cups of the following DIN/SSA systems.
O-RING 22x3 EPDM 70
Temperature Device PTD 80 | PTD 175
O-ring sitting on the bottom plug of cups of the following DIN/SSA systems.
VISCOSITY STANDARD ANTON PAAR N26 (C) 100 ml - 50 / 21 / 4.2 mPa.s
Temperature Device PTD 80 | PTD 175
Recommended for DIN/SSA/UL spindles
VISCOSITY STANDARD ANTON PAAR N7.5 (M) 100 ml - 10 / 5.4 / 1.6 mPa.s
Temperature Device PTD 80 | PTD 175
Recommended for DIN/SSA/UL spindles
VISCOSITY STANDARD ANTON PAAR S3 (L) 100 ml - 3.7 / 2.3 / 0.9 mPa.s
Temperature Device PTD 80 | PTD 175
Recommended for DIN/SSA/UL spindles
VISCOSITY STANDARD ANTON PAAR N415 (H) 100 ml - 1100 / 330 / 32 mPa.sc
Temperature Device PTD 80 | PTD 175
Recommended for DIN/SSA/UL spindles