TAG Flash Point Tester:
TAG
- Flash point measurement: +10 °C to +110 °C
- Compliance: ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, etc.
- 10x longer lifetime: Patented ceramic-coated igniter system outlasts any comparable device
- Budget-saving: Equipped with all necessary functions
TAG 500 and TAG 300: Our next-generation closed-cup TAG flash point tester series. Guided flash point measurements (acc. to ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523, etc). For jet fuels, solvents, flavors and fragrances, chemicals, and other flammable liquids. Automatic. High-precision. -35 °C to +130 °C sample temperature range. Components with the longest lifetime on the market.
Key features
Unmatched lifetime, award-winning design
Our TAG flash point testers: Deftly engineered, highly precise, reliable, and supremely robust:
- Ceramic-coated electric igniter: 10x times longer lifetime compared to other solutions
- Multi-function head: No open cables, automatic connection to all sensors
- Calibration: Guided procedures and adjustment of sensors
- Test equipment: Available in brass, as per standard methods, or in stainless steel for corrosive sample measurements
The number one TAG flash point tester on the market
- Quick start: Easy to use, intuitive test setup
- Convenience: 7” touchscreen and a customizable smart user interface (e.g., real-time data during flash point measurements, retrieval of frequently used functions)
- Complete process: Guided workflows, full compliance
- Status light: Instrument condition monitoring, even from afar
- Wetted parts: Disassembly in seconds
- Cleaning: Fast, hassle-free; results not compromised by sample carry-over
The widest TAG flash point range on the market
TAG 500 features a groundbreaking cooling system combination for Tagliabue flash point testing:
- Hybrid: Unparalleled lab flexibility and sample spectrum size
- Internal cooling system power: Flash point test temperatures between +10 °C and +130 °C
- Extension: External cooler for flash point tests with sample temperatures between -35 °C and +130 °C
TAG 300 has a budget-friendly, straightforward internal cooling system that allows measurements with flash points between +10 °C and +110 °C.
Safety first
TAG 500 protects your staff and lab:
- Safety parameters: No accidental sample overheating
- Two independent, redundant detectors: Fail-safe fire detection
- Fire extinguisher: Fire automatically extinguished, measurements securely terminated, sample returned to safe temperature
TAG 300 can optionally be upgraded with a fire extinguisher and unique fire detection system.
Measurement data, a click away
- Test results: Automatic integration into working environment
- Reports: Printable or exportable via automated e-mail or LIMS to any location in your network
- AP Connect: Storage of tens of thousands of immediately available measurements in a single data hub, accessible from any network computer, anytime
TAG flash point tester: Compliance with relevant standards
- Standard methods: The TAG flash point tester series complies with ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523, and more international and national standards
- User-defined methods: Create user-defined equilibrium and non-equilibrium testing methods adapted to your needs by using the intuitive user interface of the TAG flash point tester series
Technical specifications
TAG 300 | TAG 500 | |
Test methods | ASTM D56 Equilibrium procedures: ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 >1,000 user-defined test programs | |
Application range (flash point temperature) | +10 °C to +110 °C | Internal cooling +10 °C to +130 °C External cooling -30 °C to +130 °C |
Sample temperature range | -7 °C to +110 °C | Internal cooling -7 °C to 130 °C External cooling -35 °C to +130 °C |
Ignition type | Electric (encapsulated hot wire) | Electric (encapsulated hot wire) Optional gas ignition |
Heating rate | According to standard or user-defined | |
Cooling | Fan-supported internal Peltier cooling technology | Fan-supported internal Peltier cooling technology or external cooler |
Barometric pressure correction | Flash point is automatically corrected to barometric pressure | |
Flash detection | Automatic detection by thermocouple | |
Sample temperature | Measured by Pt100 | |
Safety | Overheat protection, automatic shut-off | Detects a “flash” outside the cup Optional automatic fire-extinguishing system in combination with a unique optical fire detection system User management with different access levels | Overheat protection, automatic shut-off | Detects a “flash” outside the cup Automatic fire-extinguishing system in combination with a unique optical fire detection system as standard User management with different access levels |
Calibration | Calibration of sample and block temperature, and internal barometer | |
Handling | TFT touchscreen | Small footprint | Manual lifting/lowering of multi-function head | No open cables | User-definable measurement parameters and units | Display of test progress in real time | TFT touchscreen | Small footprint | Fully automatic multi-function head | No open cables | User-definable measurement parameters and units | Display of test progress in real time |
Memory | 1 GB space for approx. 50,000 tests and 1,000 users | |
Statistics | Mean, min, max, repeatability, standard deviation, max. deviation | |
Interfaces | 2 × USB, 1 × LAN | 4 × USB, 1 × LAN |
Input options | Optional USB keyboard/mouse/barcode reader | |
Display | 7" TFT, PCAP touchscreen | |
Power supply | 100 V to 240 V, 50/60 Hz, 300 W | |
Gas supply | Optional fire extinguisher: CO2 or N2 inert gas; inlet pressure 400 kPa to 500 kPa | Integrated fire extinguisher: CO2 or N2 inert gas; inlet pressure 400 kPa to 500 kPa Optional gas ignition: 50 mbar of propane or butane |
Dimensions | 262 mm × 472 mm × 437 mm (W × D × H) | 262 mm × 497 mm × 477 mm (W × D × H) |
Weight | Ca. 14 kg | Ca. 15 kg |
Options | Standard test insert in brass or stainless steel, calibration set, condensation protection, draft shield Fire extinguisher | Standard test insert in brass or stainless steel, calibration set, condensation protection, draft shield Gas igniter |
Standards
ASTM
ISO
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
TAG 500: ASTM Proficiency Testing Program for Flash Points of Jet Fuel Application Reports
-
Testing the Flammability of Battery Electrolytes with TAG X00 Application Reports
-
Brochure: Flash Point Testers Brochures
-
Datasheet: TAG X00 Brochures
-
Reference Guide: TAG X00 Manuals
-
CoC TAG 300 version 1.3.6 Software and Firmware
-
CoC TAG 500 version 1.3.6 Software and Firmware
-
Release notes - TAG 300 version 1.3.6 Software and Firmware
-
Release notes - TAG 500 version 1.3.6 Software and Firmware
-
Software update - TAG 300 version 1.3.6 Software and Firmware
-
Software update - TAG 500 version 1.3.6 Software and Firmware
Consumables
Consumables
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
PVC HOSE WITH FABRIC, d = 10 mm, 2 m
TAG 300 | 500
PVC HOSE WITH FABRIC, d = 10 mm, 3 m
TAG 300 | 500
PVC HOSE WITH FABRIC, d = 10 mm, 4 m
TAG 300 | 500
CONDENSATION PREVENTION KIT
TAG 300 | 500
- Condensation prevention shield (P/N 257661)
- Sealing for condensation prevention shield (P/N 257660)
- Bottom sealing of condensation prevention shield (P/N 257659)
ELECTRIC IGNITER SET ABA X00, TAG X00
TAG 300 | 500
DRAFT SHIELD FOR FLASH POINT TESTERS
TAG 300 | 500
MULTI-DETECTOR, STANDARD, TAG X00
TAG 300 | 500
LID, BRASS, ASTM D56, TAG X00
TAG 300 | 500
LID, STAINLESS STEEL, TAG X00
TAG 300 | 500
TEST CUP, STAINLESS STEEL, TAG X00
TAG 300 | 500
TEST SET, ASTM D56, (TEST CUP, LID, MULTI-DETECTOR), TAG X00
TAG 300 | 500
- 1 standard test cup made of brass (P/N 255601)
- 1 lid (P/N 251580)
- 1 multi-detector (P/N 251539)
TEST SET, STD. VOLUME, CUP, LID, MULTI- DETECTOR, STAINLESS STEEL, TAG X00
TAG 300 | 500
- 1 standard test cup made of stainless steel (P/N 252935)
- 1 lid made of stainless steel (P/N 252799)
- 1 multi-detector (P/N 251539)
TEST CUP, BRASS, ASTM D56, TAG X00
TAG 300 | 500