Laser Diffraction Particle Size Analyzer:
Litesizer DIF
- Measure samples from 0.01 µm to 3,500 µm
- Switch between liquid and dry dispersion in just one move
- Kalliope software: No training required, dedicated QC mode
- 10-year warranty on lasers
- Image analysis module available for additional shape analysis
Litesizer DIF offers advanced particle sizing from 10 nm to 3.5 mm, drawing on nearly 60 years of laser diffraction expertise. This laser diffraction particle size analyzer boasts a best-in-class optical setup, which yields superior results. An optional image analysis module is available for additional shape analysis and reliable detection of oversized particles.
The Kalliope software simplifies particle sizing, requiring no extensive training – measurements start with just three clicks. The Quick-Click system allows easy switching between dispersion units, minimizing errors. Safety features for both liquid and dry dispersion ensure effortless, secure operation.
The robust metal housing and the isolated optical bench ensure reliability everywhere: from harsh environments, to high tech laboratories.
Fueled by our pioneering legacy, this is next-generation laser diffraction technology – Litesizer DIF: From First to Best.
Key features
On quality, we lead the way
Litesizer DIF is the perfect tool for particle analysis due to its high-quality manufacturing. It features high-grade hardware, empowering the instrument to collect superior raw data. Litesizer DIF 500 enables users to measure a broad range of samples, covering particle sizes from 0.01 µm to 3,500 µm. Litesizer DIF 300 and 100cover a more targeted range for dedicated analysis of narrower size distributions.
Kalliope: The benchmark software for particle sizing
With Kalliope, users immediately know how to get started, via the one-page-only workflow (setting parameters, acquiring and working with results). Additionally, QC mode offers consistent reliable measurement results by customizing user management and locking delicate settings. The instrument in QC mode gives simple feedback if your product is within your defined limits. This means results in just three clicks and less training for new users. In addition, a pharma option with data security functions, user management, and audit trails is included, making Kalliope compliant with the US FDA’s 21 CFR Part 11.
Efficient dispersion, maximum safety
Litesizer DIF's Quick-Click feature connects the dispersion units in just one move – no hassle with cables, tubes, or pipes. When it comes to adding the sample, the obscuration level indicator allows you to monitor the sample amount while adding it, ensuring you get the right amount from the start. Our dispersion units are designed with safety in mind: The Dry Jet dispersion unit has a suction check and built-in dust cover to minimize the risk of powder spread. Plus, the Liquid Flow dispersion unit automatically checks for sufficient liquid before sonication, preventing overheating.
Particle sizing in any environment
Anton Paar's Litesizer DIF is suitable for heavy industries. It is made of high-quality components inside and out, and has a 10-year warranty on the lasers. Sturdy metal housing encases durable optical elements. Litesizer DIF is built to endure harsh environments: No dust or powder can penetrate into the optical bench of the instrument, and the inside of the instrument is isolated from possible direct vibrations at the production site. All of this means you save on upkeep and repair costs.
Sharper Results with Image-Enhanced Diffraction
Litesizer DIF can be enhanced by image analysis, which gives an additional insight into the particle shape and allows detection of single oversized particles.
Compatibility of dispersion units between Anton Paar’s Litesizer DIA and Litesizer DIF instruments reduces investment costs and lab space usage. On top of that, all Litesizer instruments can be operated using a single PC with the Kalliope software installed.
Specifications
| Litesizer DIF 500 | Litesizer DIF 300 | Litesizer DIF 100 | |
|---|---|---|---|
| Measurement principle | Laser Diffraction (Mie and Fraunhofer scattering) | ||
| Measurement range | 0.01 μm - 3,500 μm | 0.1 μm - 2,500 μm | 0.1 μm - 1,000 μm |
| Size classes | 144 (user adjustable) | 114 (user adjustable) | 104 (user adjustable) |
| Accuracy * | better than ± 0.5 % variation*** | ||
| Repeatability | better than ± 0.5 % variation*** | ||
| Reproducibility** | better than ± 1 % variation*** | ||
| Typical measurement duration | <10 sec | ||
| Data acquisition rate | 16 kHz | ||
| Light source 1 | |||
| Type | Fiber coupled laser diode | ||
| Optical arrangement | Reverse Fourier setup | ||
| Wavelength | 830 nm, infrared | ||
| Power | 10 mW | ||
| Laser Class | Class 1 (IEC60825-1) | ||
| Light source 2 | Litesizer DIF 500 | - | |
| Type | Laser diode | - | |
| Optical arrangement | Tilted relative to IR laser | - | |
| Wavelength | 450 nm, blue | - | |
| Power | 25 mW | - | |
| Laser Class | Class 1 (IEC60825-1) | - | |
| Detectors | |||
| Type | Log-spaced photo diode array and single diodes for side and back-scattering | ||
| Angular range | 0.01° - 170° | 0.01° - 155° | |
| Focal length | 300 mm | ||
| Alignment | Automatic | ||
| Instrument data | |||
| Instrument dimensions**** | 400 mm x 790 mm x 290 mm (H x W x D) | ||
| Instrument weight**** | 42.3 kg (93.2 lb) | ||
| Power supply | 100 V to 240 V ±10 %, 50/60 Hz | ||
Trademarks:
• Kalliope (EU: 012709391), (UK: UK00912709391)
• Litesizer (EU: 011695491), (UK: UK00911695491)
* Defined for a monomodal latex standard and accounting for manufacturer's uncertainty of standard size.
** Defined for D50 of a polydisperse standard.
*** Sample and preparation dependent. Defined for liquid dispersion measurements.
**** Without PC and dispersion unit
Standards
CFR
Standards
CFR
Standards
CFR
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Accuracy, Repeatability and Reproducibility of Litesizer DIF 500 Application Reports
-
E-Book - A Practical Guide for Great Building Materials Application Reports
-
E-Book - The Field Guide to Data Integrity in Regulated Industries Application Reports
-
E-Book - The Field Guide to Pharmaceutical Powder Characterization Application Reports
-
From Theory to Real-World Precision - Performing Nanometer-Scale Measurements Application Reports
-
Heavy Duty Made Easy: Particle Size Analysis for the Cement Industry Application Reports
-
Liquid Flow Imaging (LFI): beyond laser diffraction Application Reports
-
Mie and Fraunhofer: use the correct approximation model Application Reports
-
Brochure | Litesizer Series Brochures
-
Dry Jet dispersion unit - IMSI Manuals
Similar products
Complementary products
If you do not find the item you require, please contact your Anton Paar sales representative.
Automation Option for Particle Analysis:
Litesizer Autosampler
Litesizer DIF 500 | 300 | 100
- Measure liquid and dry samples
- Measure up to 60 samples per run
- Add and prioritize samples even during an active run
- Ensure safety with cobot functionality
Accessory for Litesizer DIA and DIF:
Dispersion Unit Liquid Flow
Litesizer DIF 500 | 300 | 100
- Dispersion of samples using a carrier liquid
- Automated filling, draining, and rinsing of the dispersion liquid
- Prevention of overheating with automatic recognition of liquid
- Dedicated version with high chemical resistance available for handling aggressive liquids
- Available for the Litesizer DIA and Litesizer DIF series
Accessory for Litesizer DIA and DIF:
Dispersion Unit Dry Jet
Litesizer DIF 500 | 300 | 100
- Dispersion of samples using pressurized air
- Automation for optimal sample feeding rate
- Prevention of toxic or explosive sample spread with safety cover
- Containment of dangerous samples with automatic suction check
- Available for the Litesizer DIA and Litesizer DIF series
Accessory for Litesizer DIA and DIF:
Dispersion Unit Liquid Flow Imaging
Litesizer DIF 500 | 300
- Combination of laser diffraction and dynamic image analysis
- Measurement of shape parameters from 5 µm to 2,500 µm
- Dispersion of samples using a carrier liquid
- Inclusion of all features of the liquid flow dispersion unit
- Only available for the Litesizer DIF series
Particle analysis software:
Kalliope
Litesizer DIF 500 | 300 | 100
- Particle analysis software for all Litesizer instruments
- Particle measurement start in just three clicks
- One-page workflow user interface
- Live monitoring of measurement results, analysis function
MEASUREMENT WINDOW FOR LIQUID FLOW DISPERSION UNIT
Litesizer DIF 300 | 100