Cleveland Flash & Fire Point Tester:
CLA 5
- Cleveland open-cup flash point tester (ASTM D92, ISO 2592, and more)
- Flash and fire point testing of lubricants and bitumen
- Safety: automatically lights up the test flame, relights it, and suppresses the gas source at the end of the test
The automatic Cleveland Open-Cup (COC) measures and describes the properties of a sample in response to heat and a test flame under controlled conditions. The flash point measures the tendency to form a flammable mixture with air while the fire point indicates the tendency of sustained burning.
CLA 5 is suitable for flash and fire point applications of lubricants or bituminous material.
Key features
Benefits at a Glance
- Memory for 1000 tests, 20 operators, 100 sample names, 21 test methods
- Statistical analysis (Min, Max, Mean, Repeatability)
- Measures flash points of silicone samples without any problems
- Automatically lights up the test flame, relights it by an electric igniter and suppresses the gas source at the end of the test
Convenient Operation
- Test initiation by pre-installed standard test methods and ability to customize methods by 10 user-defined programs.
- Alert messages for out-of-spec results
- Pt100 sample temperature probe calibration either by dynamic calibration against certified ASTM thermometer or by correction table with 21 calibration points.
- Calibration protocol printout
- 5.7” color graphics display shows real-time measurement
- Menu navigation by jog shuttle system with easy turn-and-push operation and color-coded LED indication for each operation mode
- Data handling via USB stick for import into MS Excel® or to LIMS
Customized User Flexibility
- PC-software FPPNet (optional) for convenient remote handling and test data storage
- Automatic skin removal kit (optional)
- Draft deflector (optional)
- Stainless steel or glass (optional) sample temperature probe Pt100
Specifications
Application range | up to 400 °C (°C/°F selectable) |
---|---|
Ignition | Gas |
Heating | According to methods, programmable and pre-heat mode |
Detection of flash and fire point | Ionization detector |
Sample temperature | Pt100 probe |
Barometric pressure correction | Automatic correction |
Safety | Overheat protection, automatic shut-off |
Interfaces | 3x USB, 1x RS232, LAN |
Gas supply | 50 mbar of propane or butane |
Power supply | 115 V/230 V, 50 Hz/60 Hz, 600 W |
Dimensions | 230 mm x 390 mm x 460 mm (W x D x H) |
Weight | 12 kg |
Resolution | 0.1 °C |
Standards
AASHTO
ASTM
IP
ISO
JIS
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
CLA 5 - Preventing Bitumen Surface Skin Application Reports
-
Brochure: Flash Point Testers Brochures
-
Datasheet: CLA 5 Brochures
-
Pave your way - Asphalt Flyer Brochures
-
Reference Guide: CLA 5 Manuals
-
CoC CLA 5 Version 1.32.0 Software and Firmware
-
Firmware update - CLA 5 (Version 1.32.0) Software and Firmware
-
PC-Software - FPPNet Print - Excel Macro (Version 17.1) Software and Firmware
-
Release Notes - CLA 5 (FW v1.32.0) Software and Firmware
Consumables
Consumables
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.

DRIP PANS, 20 mL, ALUMINUM, PACK OF 10

FILTER PAPER, NO. 417, PACK OF 50

SKIMMER (CLA 5)

TEMPERATURE SENSOR 1, SAMPLE PT100, GLASS (CLA)

ELECTRIC IGNITER (PMA 5, PMA 4 SC, PM 4, ABA 4, TAG 4,CLA 5)

CUP, BRASS (CLA)

TEMPERATURE SENSOR 2, SAMPLE PT100, METAL (CLA)

TEMPERATURE SENSOR 2, SAMPLE PT100, GLASS (CLA)