Cleveland Flash & Fire Point Tester:
CLA 5
- Cleveland open-cup flash point tester (ASTM D92, ISO 2592, and more)
- Flash and fire point testing of lubricants and bitumen
- Safety: automatically lights up the test flame, relights it, and suppresses the gas source at the end of the test
The automatic Cleveland Open-Cup (COC) measures and describes the properties of a sample in response to heat and a test flame under controlled conditions. The flash point measures the tendency to form a flammable mixture with air while the fire point indicates the tendency of sustained burning.
CLA 5 is suitable for flash and fire point applications of lubricants or bituminous material.
Specifications
Application range | up to 400 °C (°C/°F selectable) |
---|---|
Ignition | Gas |
Heating | According to methods, programmable and pre-heat mode |
Detection of flash and fire point | Ionization detector |
Sample temperature | Pt100 probe |
Barometric pressure correction | Automatic correction |
Safety | Overheat protection, automatic shut-off |
Interfaces | 3x USB, 1x RS232, LAN |
Gas supply | 50 mbar of propane or butane |
Power supply | 115 V/230 V, 50 Hz/60 Hz, 600 W |
Dimensions | 230 mm x 390 mm x 460 mm (W x D x H) |
Weight | 12 kg |
Resolution | 0.1 °C |
Standards
AASHTO
ASTM
IP
ISO
JIS
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
CLA 5 - Preventing Bitumen Surface Skin Application Reports
-
E-Book - Analytical Methods for the Evaluation of Lubricants Application Reports
-
Flash Point Proficiency Testing of Lubricants Application Reports
-
Testing of Immersion Cooling Fluids Application Reports
-
Brochure: Flash Point Testers Brochures
-
Datasheet: CLA 5 Brochures
-
Pave your way - Asphalt Flyer Brochures
-
Reference Guide: CLA 5 Manuals
Complementary products
If you do not find the item you require, please contact your Anton Paar sales representative.

DRIP PANS, 20 mL, ALUMINUM, PACK OF 10
Drip pans made of aluminum. 10 pieces.

FILTER PAPER, NO. 417, PACK OF 50
Spare filter paper for the skin prevention set according to ASTM D8254.

SKIMMER (CLA 5)
Skimmer to remove the surface film of bituminous samples.

TEMPERATURE SENSOR 1, SAMPLE PT100, GLASS (CLA)
Pt100 temperature sensor made of glass

ELECTRIC IGNITER (PMA 5, PMA 4 SC, PM 4, ABA 4, TAG 4,CLA 5)
Electric igniter with cable.

CUP, BRASS (CLA)
Standard Cleveland test cup with handle made of brass

TEMPERATURE SENSOR 2, SAMPLE PT100, METAL (CLA)
Pt100 temperature sensor made of metal. Only suitable for CLA 5 instruments with S/N 60029904 and higher.

TEMPERATURE SENSOR 2, SAMPLE PT100, GLASS (CLA)
Pt100 temperature sensor made of glass. Only suitable for CLA 5 instruments with S/N 60029904 and higher.