This is a required field.
Invalid
Part number
Error in validation!

Accessories for XRDynamic 500:
Automated Sample Changer

  • XRDynamic Autosampler with vertical sample magazines holding samples for automated X-ray diffraction.
  • XRDynamic Autosampler robot arm with single vertical sample magazine and a disc-shaped sample holder placed separately.
  • Lab technician loading a sample into the XRDynamic Autosampler, featuring  vertical magazines inside the closed XRDynamic 500 housing.
  • XRDynamic Autosampler with vertical sample magazines holding samples for automated X-ray diffraction.
  • Two sample magazines and various sample holders used with the XRDynamic Autosampler, arranged on a light background.
  • Sample holder with yellow powder positioned above the measurement stage, provided by XRDynamic Autosampler.
  • Technician installing the XRDynamic Autosampler inside the XRDynamic 500 X-ray diffraction system during setup or maintenance.
  • XY-12 sample stage installed on the XRDynamic 500 X-ray diffraction system, loaded with sample holders.
  • XRDynamic Autosampler with vertical sample magazines holding samples for automated X-ray diffraction.
  • XRDynamic Autosampler robot arm with single vertical sample magazine and a disc-shaped sample holder placed separately.
  • Lab technician loading a sample into the XRDynamic Autosampler, featuring  vertical magazines inside the closed XRDynamic 500 housing.
  • +6
Model:
  • Autosampling of up to 105 samples
  • Supports all sample types, e.g. powders, solids, fibers, thin films
  • Delivers consistent, high-quality data
  • Fully integrated, fully automated operation prevents errors
Pick your country.
Americas
Brazil
PT
Canada
EN | FR
Colombia
ES
Mexico
ES
Peru
ES
United States
EN
Europe
Austria
DE
Belgium
EN | FR
Croatia
EN
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Africa & Middle East
South Africa
EN
Turkey
TR
United Arab Emirates
EN
Asia-Pacific
Australia
EN
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Philippines
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
EN
Vietnam
EN | VI
If you can't find your country in the list get a quote

The XRDynamic Autosampler and sample changer options for the XYstage enhance Anton Paar’s XRD solutions with high sample capacity, seamless integration, and flexible performance. Combined with XRDynamic 500, they enable efficient, automated measurements for all sample types, with consistently reliable results.

Key features

Highest sample capacity

The XRDynamic Autosampler sets the benchmark with the ability to handle up to 105 samples using industry-standard sample holders. This unmatched capacity enables longer walkaway times, and significantly boosts lab throughput and efficiency: 

  • Supports 105 standard sample holders for transmission and/or reflection measurements
  • Designed for all sample types (powders, solids, fibers, foils, thin films, air-sensitive samples)
  • Enables extended, unattended operation
XRDynamic Autosampler with vertical sample magazines holding samples for automated X-ray diffraction.

Outstanding performance and flexibility

The XRDynamic Autosampler as well as the sample changer option for the XY stage facilitate operation and ensure precise results across various sample types and applications, thanks to automatic geometry switching and height alignment – saving hours of manual instrument adaptations

  • Supports domed holders for air-sensitive samples
  • Delivers consistent, high-quality data
Two sample magazines and various sample holders used with the XRDynamic Autosampler, arranged on a light background.

Seamless integration

Customers benefit from error minimization and efficiency maximization. Fully integrated with XRDdrive software, the sample changer option for the XY stage as well as the XRDynamic Autosampler and its magazines are instantly recognized upon connection. Combined with the automation level of XRDynamic 500, it ensures:

  • Plug-and-play setup
  • Reduced user intervention
  • High throughput with reduced manual handling errors
Sample holder with yellow powder positioned above the measurement stage, provided by XRDynamic Autosampler.

Scalable and non-intrusive

Easily mounted on any XRDynamic 500 instrument, the XRDynamic Autosampler never interferes with other measurements when it is not in use, and it is both removable and expandable: 

  • No interference with other measurements
  • Scales from one to seven magazines
  • Fast and precise installation
Technician installing the XRDynamic Autosampler inside the XRDynamic 500 X-ray diffraction system during setup or maintenance.

A portfolio covering every need

The XRDynamic Autosampler perfectly complements the existing portfolio of the XRDynamic 500 sample changer option for the XY stage, with three, six, 12, or 48 sample positions. 

This gives users even greater flexibility when it comes to choosing the perfect solution for their applications and challenges.

XY-12 sample stage installed on the XRDynamic 500 X-ray diffraction system, loaded with sample holders.

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Compatible instruments

Similar products