Entry-Level Rheometer:
MCR
- Entry-level instrument for QC rheometry
- No need for pressurized air, place it wherever you need it
- Measurements in rotation and special-application oscillation
- Ideal for measuring sample flow behavior
MCR 72 and MCR 92 are streamlined for your daily lab routine and available at a great price. The modularity allows QC measurements until now only possible in research, while saving costs because there's no need to upgrade to new, more expensive instruments. The modularity also maximizes flexibility because users can add modular elements when needed. Apply temperatures from -50 °C to +400 °C, pressures up to 150 bar, and use industry-specific upgrades to further boost your characterization capabilities.
Key features
Two models designed for your application
MCR 72 is equipped with a ball-bearing motor, which is robust and doesn’t require compressed air. MCR 92, with an air-bearing motor, is highly accurate (minimum torque of 0.4 µNm) and is used for sensitive samples. The two rheometers enable measurements in both rotational and oscillatory mode. The choice of rheometer depends on your application. To investigate the deformation and flow behavior of your sample, use MCR 72. For observing sample structure, MCR 92 is perfect. Both instruments have a motor that lifts up the measuring head automatically to set an exact measuring gap. This gap is 100 % reproducible.

The first entry-level rheometer with advanced modularity
Our rheometer sets a new standard in modularity, delivering unparalleled characterization capabilities for diverse industries. The ETD temperature device expands the temperature range from -50°C to +400°C, and is ideal for polymer QC. The optional Pressure Cell 150 offers unique entry-level QC pressure adaptability, catering to food and polymer applications. Advanced integration with dielectric spectroscopy enables simultaneous impedance and rheometric measurements for battery slurries. Additional modules allow precise starch and building material analyses, making it the only QC rheometer offering such comprehensive versatility without requiring an upgraded platform.

Step-by-step software
The RheoCompass software helps you find the test template you need, customize tests and analysis definitions, export your data, and generate reports. You are guided through your first rheological measurements with predesigned but individually adaptable templates, including integrated videos and pictures for extra support. Different accounts can be created for each operator working in the lab.

Unique features for easy handling and reproducible results
The highlight of these two rheometer models is the patented TruRay lighting of the measuring surface, which can be gradually regulated for a clear view of your sample. When changing between measuring systems, QuickConnect allows one-handed connection of the measuring systems and ensures fast, convenient system changes without the use of a screwing mechanism. Then, Toolmaste takes over by automatically recognizing the mounted tool and temperature units. Finally, the SafeGap feature ensures that the setting of the measuring gap is always identical for every measurement and exactly reproducible every time.

Experienced experts close to you
Anton Paar’s worldwide service network ensures that an expert for your system is always close by. 1,000 installed instruments around the globe, an extensive application database, a website full of practical information (World of Rheology), the book “Applied Rheology – With Joe Flow on Rheology Road”, eLearning courses, and numerous published works by our rheology experts make Anton Paar the number one choice for answering any rheological question you may have.

Specifications
Units | MCR 72 | MCR 92 | |
Bearing | - | Ball | Air |
EC motor (brushless DC) with high resolution optical encoder | - | ✓ | ✓ |
Rotation mode | - | ✓ | ✓ |
Oscillation mode | - | ✓ | (1✓ |
Direct strain controller | - | ✓ | ✓ |
Direct stress controller | - | ✓ | ✓ |
Maximum torque | mNm | 125 | 125 |
Minimum torque, rotation | µNm | 200 | 0.4 |
Minimum torque, oscillation | µNm | 200 | 0.4 |
Torque resolution | nNm | 100 | 100 |
Angular deflection, set value | µrad | 1 to ∞ | 1 to ∞ |
Angular deflection, resolution | nrad | 614 | 614 |
Step rate, time constant | ms | 100 | 100 |
Step strain, time constant | ms | 100 | 100 |
Minimum angular velocity (2 | rad/s | 10-4 | 10-4 |
Maximum angular velocity | rad/s | 157 | 157 |
Minimum angular frequency (3 | rad/s | 10-3 | 10-4 |
Maximum angular frequency | rad/s | 628 | 628 |
Minimum speed (CSS/CSR) | rpm | 10-3 | 10-3 |
Maximum speed | rpm | 1500 | 1500 |
Maximum temperature range | °C | -50 to +400 | -50 to +400 |
SafeGap, normal force limiter during gap setting | - | ✓ | ✓ |
TruRay, dimmable illumination of sample area | - | ✓ | ✓ |
Connections | USB, Ethernet, RS232, Analog interfaces, Pt100 port | ||
Dimensions | mm | 380 x 660 x 530 | 380 x 660 x 530 |
Weight | kg | 33 | 33 |
QuickConnect for measuring systems, screwless | - | ✓ | ✓ |
ToolmasterTM, measuring system | - | ✓ | ✓ |
ToolmasterTM, measuring cell | - | ✓ | ✓ |
CoolPeltierTM, Peltier-controlled plate system with built in cooling option that requires no additional accessories for counter-cooling | °C | 25(4 below ambient temperature but not lower than -10(4 to +220 (4 | |
Actively Peltier-controlled hood that requires no additional accessories for counter-cooling | °C | -5(4 to 200(4 | |
CoolPeltierTM, Peltier-controlled cylinder system with built-in cooling option that requires no additional accessories for counter-cooling | °C | 15(4 below ambient temperature but not lower than +5(4 up to +150 (4 | |
Virtually gradient-free (horizontal, vertical) temperature control | - | ✓ | ✓ |
Rheometer Software: | |||
Test designer | - | ✓ | ✓ |
Report designer | - | ✓ | ✓ |
User management | - | ✓ | ✓ |
Electronic trim lock for the measuring system | - | ✓ | ✓ |
Automatic gap control/setting, AGC/AGS | - | ✓ | ✓ |
1) Depending on sample properties
2) Depending on measuring point duration and sampling time, practically any value is achieved
3) Set frequencies below 10-4 rad/s are of no practical relevance due to the measuring point duration > 1 day
4) System temperature, sample temperature may vary. For measurements at very high or low temperatures a calibration in the sample gap is recommended.
Standards
ASTM
DIN
DIN EN
EN
ISO
IOCCC
European Pharmacopoeia (Ph. Eur.)
US Pharmacopoeia (USP)
ICA
Standards
ASTM
DIN
DIN EN
EN
ISO
IOCCC
European Pharmacopoeia (Ph. Eur.)
US Pharmacopoeia (USP)
ICA
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Beverage | Soft Drinks | Complete Your Soft Drink Analysis Application Reports
-
Calculation of the Critical Shear Rate in a Cylinder Measuring System Application Reports
-
Chocolate Yield-Stress Measurements Depend on Geometry Application Reports
-
Chocolate! How Does It Melt and Flow? Measurements with the MCR 72 Application Reports
-
Coenzyme Q10 - Organic Nanoparticle Characterization Application Reports
-
Determining Flow Behavior of Shampoo Application Reports
-
Determining the Flow Behavior of Coarse Dispersions Application Reports
-
E-Book - The Field Guide to Data Integrity in Regulated Industries Application Reports
-
Hair Gel: Viscosity and Yield Point with the MCR 72 Application Reports
-
Measuring the Flow and Recovery of Ketchup with the MCR 72 Application Reports
-
On the use of EC motors in rotational rheometers Application Reports
-
Pharmaceutical Instrument Qualification Demo Application Reports
-
Rheological Tests on Milk Drinks Application Reports
-
Rheology of Coatings: Determining the Yield Point with the MCR 72 Application Reports
-
Rheology of Coatings: Flow Point Determination with the MCR 92 Application Reports
-
Rheology of Coatings: Thixotropic Behavior with the MCR 72 Application Reports
-
Rheology of Thickeners in Pharmaceuticals: Xanthan Gum Application Reports
Similar products
Consumables & Accessories
Consumables & Accessories
Accessories
Accessories
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.

DISPOSABLE DISHES DD65/TINPLATE ID:
65 mm, TINPLATE, 1 pack = 100 pcs
MCR 72 | 92

DISP./REMOVEABLE PL. D-PP50/SS/S07 D:
50 mm, STAINLESS STEEL
MCR 72 | 92

DISPOSABLE PLATE D-PP10/AL/07 D:
10 mm, ALUMINIUM, 1 pack = 10 pcs
MCR 72 | 92

DISPOSABLE CONE D-CP25-1/AL/S07 D:
25 mm, ANGLE: 1°, AL, 1 pack = 10 pcs
MCR 72 | 92

INSET I-PP25/SS/S D:
25 mm, SS, SANDBLASTED
MCR 72 | 92

DISP./REMOVEABLE CONE D-CP40-1/SS/S07 D:
40 mm, ANGLE: 1°, STAINLESS STEEL
MCR 72 | 92

DISP./REMOVEABLE CONE D-CP25-2/SS/S07 D:
25 mm, ANGLE: 2°, STAINLESS STEEL
MCR 72 | 92

DISPOSABLE MEAS. CUP D-C-CC27/AL ASPHALT ALUMINIUM, 1 pack = 100 pcs
MCR 72 | 92

DISPOSABLE PLATE D-PP08/AL/P2/S07 D:
8 mm, ALUMINIUM, PROFILED: 1X0.5
MCR 72 | 92

DISPOSABLE PLATE D-PP05/AL/S07 D:
5 mm, ALUMINIUM, 1 pack = 10 pcs
MCR 72 | 92

SILICON MOLD FOR ASPHALT BINDER (PP04)
MCR 72 | 92

DISPOSABLE MEAS. PLATE EMP 30 D:
25 mm, ALUMINIUM, 1 pack = 10 pcs
MCR 72 | 92

DISPOSABLE MEAS. PLATE EMP 31 D:
50 mm, ALUMINIUM, 1 pack = 10 pcs
MCR 72 | 92

MEAS. CUP C-CC39/AL/XL ALUMINIUM
MCR 72 | 92

STIRRER ST22-6V-16/106 FOR X2/XX2
MCR 72 | 92

MEAS. CUP HOLDER H-D-CC27/XL
MCR 72 | 92

STIRRER ST22-4V-16/106 FOR X2/XX2
MCR 72 | 92

MEAS. CUP C-CC39/XL
MCR 72 | 92

CONNECTION KIT FOR FLUID CIRCULATORS
MCR 72 | 92

MEAS. SHAFT BC12.7 FOR XX2
MCR 72 | 92

S-LP25/AL/P2/G1 SCREW-ON LOWER MEAS. PLATE
MCR 72 | 92
- Material: hard anodized aluminium
- Suitable for all temperature devices with external thread M60
- With groove on the outer edge (G1) to prevent run off of
excess material

S-LP50/AL/P2/G1 SCREW-ON LOWER MEAS. PLATE
MCR 72 | 92
- Material: hard anodized aluminium
- Suitable for all temperature devices with external thread M60
- With groove on the outer edge (G1) to prevent run off of
excess material

S-LP25/AL/S/G1 SCREW-ON LOWER MEAS. PLATE
MCR 72 | 92
- Material: hard anodized aluminium
- Suitable for all temperature devices with external thread M60
- With groove on the outer edge (G1) to prevent run off of
excess material

S-LP50/AL/S/G1 SCREW-ON LOWER MEAS. PLATE
MCR 72 | 92
- Material: hard anodized aluminium
- Suitable for all temperature devices with external thread M60
- With groove on the outer edge (G1) to prevent run off of
excess material

S-LP62/AL/P2/G0
MCR 72 | 92
- material: hard anodized aluminium
- suitable for all temperature devices with external thread M60
- without groove

S-LP08/SP/G0 SCREW-ON LOWER MEAS. PLATE
MCR 72 | 92
- Material: hard anodized aluminium
- Suitable for all temperature devices with external thread M60
- With serial number for SmartPave
- Without groove (G0)

S-LP25/SP/G0 SCREW-ON LOWER MEAS. PLATE
MCR 72 | 92
- Material: hard anodized aluminium
- Suitable for all temperature devices with external thread M60
- With serial number for SmartPave
- Without groove (G0)

S-LP25/SS/G1 SCREW-ON LOWER MEAS. PLATE
MCR 72 | 92
- Material: stainless steel
- Suitable for all temperature devices with external thread M60
- With groove on the outer edge (G1) to prevent run off of
excess material

S-LP50/SS/G1 SCREW-ON LOWER MEAS. PLATE
MCR 72 | 92
- Material: stainless steel
- Suitable for all temperature devices with external thread M60
- With groove on the outer edge (G1) to prevent run off of
excess material

S-LP62/SS/G2 SCREW-ON LOWER MEAS. PLATE
MCR 72 | 92
- Material: stainless steel
- Suitable for all temperature devices with external thread M60
- Round groove (G2) for easy cleaning

S-LP62/SS/G0 SCREW-ON LOWER MEAS. PLATE
MCR 72 | 92
- Material: stainless steel
- Suitable for all temperature devices with external thread M60
- Without groove (G0)

S-LP75/SS/G0 SCREW-ON LOWER MEAS. PLATE
MCR 72 | 92
- Material: stainless steel
- Suitable for all temperature devices with external thread M60
- Includes fitting open-end wrench 174253
- Without groove (G0)

S-LP25/SS/P2/G1 SCREW-ON LOWER MEAS. PLATE
MCR 72 | 92
- Material: stainless steel
- Suitable for all temperature devices with external thread M60
- With groove on the outer edge (G1) to prevent run off of
excess material

S-LP25/SS/S/G1 SCREW-ON LOWER MEAS. PLATE
MCR 72 | 92
- Material: stainless steel
- Suitable for all temperature devices with external thread M60
- With groove on the outer edge (G1) to prevent run off of
excess material

VISCOSITY STANDARD DKD 2000 AW 100 ml - 1500 / 460 / 45 mPa.s
MCR 72 | 92

VISCOSITY STANDARD DKD 2000 AW 250 ml - 1500 / 460 / 45 mPa.s
MCR 72 | 92

SELF-LOCKING COUPLING
MCR 72 | 92

DUST COVER MCR RHEOMETERS SUITABLE FOR MCR 52/72/92/102/302/102e
MCR 72 | 92

P-PTD 220/AIR FOR MCR x2 PELTIER TEMPERATURE DEVICE (PLATE)
MCR 72 | 92
- plate with active Peltier temperature control (heating/cooling)
- for cone/plate and parallel plate measuring geometries
- with built-in fan for air counter-cooling
- with universal plate holder (screw-on thread) for use of measuring plates (also disposable) and other accessories
- with Toolmaster for automatic tool recognition and configuration
- installation in the rheometer through three-point support without the risk of misalignment
- maximized torsional stiffness due to constructional torque support

C-PTD 150/XL/AIR/18P AIR COOLED PELTIER TEMPERATURE DEVICE
MCR 72 | 92
- with integrated fan for counter cooling CoolPeltier
- temperature range: +5*) to 150 °C
*) The lower temperature range depends on the ambient conditions.

MEAS. CONE CP25-1 FOR X2/XX2
MCR 72 | 92

Optical accessory for MCR:
Rheometer-Infrared Spectrometer Adapter
MCR 72 | 92
- Accessory for structure analysis and rheo optics
- Lets you connect your infrared spectrometer with an MCR rheometer
- Investigates the chemical composition and rheology

MEAS. PLATE PP20 FOR X2/XX2
MCR 72 | 92

Accessory for MCR and RheolabQC:
Flexible Cup Holder
MCR 72 | 92
- Accessory for “Extended Material Characterization"
- Holds, for example: paint cans, yogurt cups, other containers
- Can be combined with stirrers, concentric cylinder geometries, and a Pt100 temperature sensor

MEAS. PLATE PP25/P2 FOR X2/XX2
MCR 72 | 92

Peltier Temperature Devices for MCR 72/92:
PTD
MCR 72 | 92
- CoolPeltier™ technology ensures accurate, efficient temperature control
- Compatible with MCR 72 and MCR 92 rheometers for precise measurements
- Supports various measuring systems
- Ideal for a wide range of sample consistencies: no need for liquid cooling

MEAS. PLATE PP25/S FOR X2/XX2
MCR 72 | 92

MEAS. CYLINDER B-CC27 FOR X2/XX2
MCR 72 | 92

LOWER MEAS. PLATE L-PP50/SS/CTD D:
50 mm, NO GROOVE, SS
MCR 72 | 92

Accessory for MCR:
Rheometer Geometries
MCR 72 | 92
- Wide range of measuring systems for RheolabQC and the MCR rheometer series
- Concentric cylinder, double-gap, cone-plate, and parallel-plate systems, vane geometries and spindles, Krebs spindles
- Customized solutions upon request

MEAS. CUP HOLDER H-D-CC27
MCR 72 | 92

MEAS. PLATE PP08 FOR X2/XX2
MCR 72 | 92

LOWER MEAS. PLATE L-PP08-3.5/SS/CTD D:
8 mm, SS, RAISED MEAS. SURFACE: 3.5mm
MCR 72 | 92

MEAS. CONE CP60-1 FOR X2/XX2
MCR 72 | 92

SHAFT FOR DISPOSABLE MEASURING- SYSTEMS D-CP/PP 7, WITHOUT TOOLMASTER
MCR 72 | 92

INSET I-PP25/SS D:
25mm, SS
MCR 72 | 92

INSET I-PP50/SS D:
50mm, SS
MCR 72 | 92

INSET I-PP60/SS D:
60 mm, SS
MCR 72 | 92

INSET I-PP08/SS (WITH GROOVE) D:
8 mm, SS
MCR 72 | 92

MEAS. CONE CP50-1 FOR X2/XX2
MCR 72 | 92

MEAS. CONE CP50-2 FOR X2/XX2
MCR 72 | 92

MEAS. PLATE PP25 FOR X2/XX2
MCR 72 | 92

MEAS. PLATE PP50 FOR X2/XX2
MCR 72 | 92

INSET I-PP04/CU/CX (WITH GROOVE) D:
4 mm, COPPER ALLOY, CERID COATING
MCR 72 | 92

MEAS. PLATE PP04 FOR X2/XX2
MCR 72 | 92

COVER / SOLVENT TRAP 80 mm PEEK|FOR P-PTD 200 / P-PTD 220
MCR 72 | 92
- suitable up to 220 °C and solvent-based samples
- suitable as solvent trap for PP/CP measuring geometries > 25 mm
- suitable as cover for all PP/CP measuring geometries up to 75 mm
- can be put in place after sample loading and trimming
- can not be used in combination with active Peltier hood

MEAS. PLATE PP15 FOR X2/XX2
MCR 72 | 92

MEAS. CONE CP25-2 FOR X2/XX2
MCR 72 | 92

MEAS. CONE CP35-1 FOR X2/XX2
MCR 72 | 92

MEAS. CUP C-CC27/XL
MCR 72 | 92

MEAS. CUP C-CC27/AL/XL ALUMINIUM
MCR 72 | 92

MEAS. CONE CP25-0.5 FOR X2/XX2
MCR 72 | 92

MEAS. PLATE PP12 FOR X2/XX2
MCR 72 | 92

MEAS. CONE CP20-0.5 FOR X2/XX2
MCR 72 | 92

MEAS. SYSTEM CC39/XL FOR X2/XX2
MCR 72 | 92
- Meas. cylinder B-CC39
- Meas. cup C-CC39/XL

MEAS. CONE CP60-0.5 FOR X2/XX2
MCR 72 | 92

MEAS. CONE CP40-0.3 FOR X2/XX2
MCR 72 | 92

MEAS. CYLINDER B-CC17 FOR X2/XX2
MCR 72 | 92

MEAS. CUP HOLDER H-D-CC14
MCR 72 | 92

MEAS. CYLINDER B-CC28.72-15 FOR X2/XX2
MCR 72 | 92

MEAS. CONE CP75-1 FOR X2/XX2
MCR 72 | 92

INSET I-PP80/SS D:
80 mm, SS
MCR 72 | 92

MEAS. CUP C-CC27/C/AIR CLOSED BOTTOM
MCR 72 | 92

MEAS. SYSTEM CC27/AIR FOR X2/XX2
MCR 72 | 92
- Meas. cylinder B-CC27
- Meas. cup C-CC27/AIR

MEAS. SYSTEM DG26.7/AIR FOR X2/XX2
MCR 72 | 92
- Meas. cylinder B-DG26.7
- Meas. cup C-DG26.7/AIR

H-PTD 200/AIR/18P AIR-COOLED PELTIER HOOD
MCR 72 | 92
- with integrated fan for counter cooling CoolPeltier,
- incl. flow valve,
- temperature range: -5* to 200 °C.
* Lower temperature range depends on ambient conditions.

MEAS. PLATE PP40 FOR X2/XX2
MCR 72 | 92

MEAS. PLATE PP50/P2 FOR X2/XX2
MCR 72 | 92

DISP. LOWER MEAS. PLATE D-L-PP08/AL/CTD D 8 mm, ALUMINIUM, 1 pack = 10 pcs
MCR 72 | 92

MEAS. PLATE PP50/S FOR X2/XX2
MCR 72 | 92

MEAS. CONE CP40-2 FOR X2/XX2
MCR 72 | 92

MEAS. CONE CP50-0.5 FOR X2/XX2
MCR 72 | 92

MEAS. CONE CP40-1 FOR X2/XX2
MCR 72 | 92

INSET I-PP50/CU/CX D:
50 mm, COPPER ALLOY, CERID COATING
MCR 92

SPATULA
MCR 72 | 92

MEAS. SYSTEM CC39/AL/XL FOR X2/XX2
MCR 72 | 92
- Meas. cylinder B-CC39
- Meas. cup C-CC39/AL/XL