Density Meter:
DMA 4200 M
- Density meter for heavy petroleum samples
- Compliant with ASTM D4052, ASTM D5002, and ASTM D8188
- 10 times faster measurement than with manual methods like pycnometers (ASTM D70)
- Small sample volume of 2 mL to 3 mL; easy to clean
The new DMA 4200 M is a density meter for exceptional conditions. It measures the density at temperatures between -10 °C and 200 °C and elevated pressures up to 500 bar. The Pulsed Excitation Method used by DMA 4200 M delivers the most stable density results based on comprehensive knowledge of the oscillation characteristics. The new automatic bubble detection, FillingCheck™, makes the DMA 4200 M compliant with ASTM D4052 and ASTM D5002. Viscosity influence is eliminated by a fast new viscosity correction, ensuring density results with an accuracy of up to 0.0002 g/cm3. The new Temperfect™ feature of DMA 4200 M allows immediate density measurements at any temperature between 0 °C and 150 °C at ambient pressure.
DMA 4200 M improves, accelerates, and simplifies density measurement of heavy petroleum samples.
Key features
Saves you time, money, and solvent
- Small sample volume of 2 mL to 3 mL
- 10 times faster measurement than manual methods like pycnometers (ASTM D70)
- Low solvent consumption for cleaning routines
- Quick cleaning routines
Compliant and reliable results
- New automatic bubble detection: FillingCheck™ ensures correctly reported results
- ASTM D4052 and ASTM D5002 compliant
- Fast and new viscosity correction
- Reliable tool for density measurement at elevated temperatures and pressures
Strong and fast U-tube
- High chemical resistance to sour gas, hydrochloric acid, and hydrofluoric acid
- No risk of corrosion and breakage
- Patented Pulsed Excitation Method for fast measurement (AT 516420 B1)
- Made of Hastelloy C276, an alloy that is more robust than stainless steel
Quality control of petroleum samples
- From upstream to downstream
- On incoming crude oil
- On intermediate and process samples to give a quick feedback on the refining process
- For converting volume to mass when trading asphalt/bitumen
- Replaces pycnometers and hydrometers
Suitable for density studies in research
- Determination of equation of state
- Calculation and configuration of production processes
- Pressure-volume-temperature (PVT) analysis of crude oil
- Bubble-point determination of crude oil
- The fast and accurate alternative to pressure hydrometers and pycnometers
Technical specifications
Patent granted | AT 516420 B1 |
Measuring range Density Temperature | 0 g/cm³ to 3 g/cm³ -10 °C to 200 °C (14 °F to 392 °F) |
Pressure range | 0 bar to 500 bar (7250 psi) |
Accuracy* Density Temperature | 0.0002 g/cm³ 0.03 °C (0.05 °F) |
Repeatability, s.d.** Density Temperature | 0.00005 g/cm³ 0.01 °C (0.02 °F) |
Reproducibility, s.d.** Density | 0.0001 g/cm³ |
Digital Resolution | 0.00001 g/cm³ |
FillingCheck™ | Yes (at ambient pressure and up to 150 °C) |
Full range viscosity correction | Yes (at ambient pressure) |
Temperfect™ | Yes (at ambient pressure) |
Pulsed Excitation Method | Yes |
Minimum sample volume | 2 mL |
Wetted materials | Hastelloy C276 |
Footprint | 510 mm x 330 mm (20 in x 13 in) |
ASTM standards | D4052, D5002 |
Power supply | AC 100 to 240 V, 50 to 60 Hz, 250 VA |
Connections | Pressure fittings for metal tubes with 1/8" outer diameter |
Interfaces | 4 x USB (2.0 full speed), 1 x Ethernet (100 Mbit), 1 x CAN Bus, 1 x RS-232, 1 x VGA |
*this is valid under ideal measuring and sample conditions only (at ambient pressure)
**this is valid under ideal measuring and sample conditions only (at ambient pressure), according to ISO 5725
Standards
ABNT
ASTM
GB
ISO
RANP
US Pharmacopoeia (USP)
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Accurate density results in wide temperature and pressure ranges with DMA 4200 M Application Reports
-
Cleaning recommendations for Anton Paar DMA instruments Application Reports
-
DMA 4200 M is ASTM compliant Application Reports
-
Density measurement of bitumen or asphalt Application Reports
-
Determination of the density of liquefied petroleum gas Application Reports
-
Brochure | DMA 4200 M Brochures
-
Pave your way - Asphalt Flyer Brochures
-
Density measurement redefined (LAB Worldwide 02/2019) Customer Reports and Publications
-
Success Story: H&R Group Customer Success Stories
-
DMA 4200 M | Reference guide Manuals
-
DMA 4200 M | SOP Manuals
Consumables, Accessories, Software & Reference materials
Consumables, Accessories, Software & Reference materials
Accessories & Software
Accessories & Software
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
CONNECTION TUBE
CONNECTION HOSE LPG-ADAPTER
QUICK CONNECTOR FOR 1/8" TUBE
LUER-LOCK ADAPTER DMA™ 4200 M
INJECTION ADAPTER LUER-LOCK
TEST TUBE RACK 12 ml / 60 POSITIONS
VIAL 50 mL POLYSTYRENE (50 Pcs.)
DENSITY STANDARD SODIUM BROMIDE
SET OF CAPS SILICONE (30 pcs.)
SET OF CAPS SILICONE 12 ml D14 (30 Pcs.)
SYRINGE HOLDER 5 ml FOR 5 ml PLASTIC SYRINGE
HOSE 3x5 SILICONE
HOSE 2x4 VITON
HOSE 4X6 SILICONE
SYRINGES 2 ml LUER (10 PCS)
ADAPTER UNF 1/4"-LUER MALE
SYRINGES 2 ml LUER (1000 PCS)
VIAL 12 ml GLASS (100 Pcs.)
VISCOSITY STANDARD ANTON PAAR S3 (L) 100 ml - 3.7 / 2.3 / 0.9 mPa.s
Recommended for DIN/SSA/UL spindles
COLOR ADJUSTMENT SET 3x ULTRA-PURE WATER 2x color standards (50 ml).
ADAPTER LUER CONE
SYRINGE 2 ml LUER (1 PCS)
SYRINGES 5 ml LUER (100 pcs.)
SYRINGES 5 mL LUER-LOCK (100 PCS)
SYRINGE 10 mL LUER-LOCK
Accessory for DMA 4200 M:
Syringe Heating Accessory
- For filling samples with a high melting point, e.g. bitumen, asphalt, waxes, plastics
- Keeps samples heated at up to 200 °C
- Simplifies filling, sample handling
Filling Device for Liquid Gases:
LPG-Adapter for DMA 4200 M
- Filling device for liquid gases: LPG adapter for DMA 4200 M
- Equips your density meter to measure propane, butane, and propane-butane mixtures from various sample containers
- Installation in less than 5 sec
- Simple, safe operation
DRYING CARTRIDGE
KEYBOARD USA USB
KEYBOARD GERMAN USB
PRINTER EPSON TM-U220
BARCODE SCANNER 2D WITH USB CABLE
Only for ViscoQC 300
RIBBON CARTRIDGE FOR CITIZEN PRINTER CBM910 / IDP3110
Lab Execution Software:
AP Connect Start
- Now: 100 % discount at checkout!
- Kickstart your paperless lab
- Featuring key benefits of the Standard edition
- Restricted to one instrument, single user access, one export rule
Lab Execution Software:
AP Connect Standard subscription license
- Annual fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips
Lab Execution Software:
AP Connect Standard one-time license
- One-time fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips
Lab Execution Software:
AP Connect Pharma subscription license
- Annual fee per instrument
- Time-saving processes: automatic, digital data transfer
- Assurance of lab data integrity
- Fast decisions: data at your fingertips
Lab Execution Software:
AP Connect Pharma one-time license
- One-time fee per instrument
- Time-saving processes: automatic, digital data transfer
- Assurance of lab data integrity
- Fast decisions: data at your fingertips
DENSITY STANDARD TRIMETHYLPENTANE
DENSITY STANDARD LUBE OIL LARGO 8cSt@40°C
DENSITY STANDARD ETHANOL IN WATER 40%ABV
DENSITY STANDARD ETHANOL IN WATER 9%ABV
DENSITY STANDARD DEXTROSE IN WATER 10%W/W
DENSITY STANDARD ANTON PAAR S600HT 100 ml - 0.830/0.800 g/cm³ at 100/150 °C