Rolling-ball viscometer:
Lovis 2000 M/ME
- Measures dynamic viscosity and relative viscosity from only 100 µL of sample
- Powerful polymer software automatically delivers intrinsic viscosity, molar mass, K-value, and more
- Referenced in US and European Pharmacopoeia
upon request
in specific countries
Lovis 2000 M/ME is a rolling-ball viscometer which measures the rolling time of a ball through transparent and opaque liquids based on Hoeppler's falling ball principle. The instrument is mainly used for viscosity measurements of low viscous liquids for R&D applications, in the pharmaceutical and chemical industries. A measurement with Lovis 2000 M/ME can yield dynamic viscosity, intrinsic viscosity, molar mass of a polymer and more.
Key features
For R&D
- Small sample amount (starting from 100 μL)
- Sample recovery
- Wide temperature range (-30 °C to 100 °C /-22 °F to 212 °F)
- Wide viscosity range (0.3 mPa.s to 10,000 mPa.s)
- High accuracy
- Variable inclination angle for testing shear-dependent flow behavior
For pharmaceutical and medical labs
- Included in US and European Pharmacopoeia
- Pharma qualification packages available
- Optional modular combination with Anton Paar instruments for measuring density, refractive index, turbidity and pH value
- Flow-through filling for large sample throughput
For the chemical industry
- Hermetically closed system for volatile or toxic samples
- High chemical resistance (borosilicate glass or PCTFE)
- Special polymer measuring and evaluation features
- Automatic filling using autosampler
- Testing of opaque samples
Technical specifications
Viscosity | |||
---|---|---|---|
Viscosity range | 0.3 mPa.s to 10,000 mPa.s | ||
Repeatability s.d. | up to 0.1 % 1) | ||
Accuracy | up to 0.5 % 1) 2) | ||
Temperature | |||
Temperature range | + 5 °C to 100 °C | ||
Repeatability s.d. | 0.005 °C | ||
Accuracy | 0.02 °C | ||
Measuring time | |||
Resolution | 0.001 s | ||
Accuracy | 0.05 % | ||
Further specifications | |||
Test duration | minimal 30 s, typical 3 min | ||
Sample volume | 0.1 mL to 0.8 mL | ||
Inclination | 15° to 80° in 1° steps | ||
Repeatability s.d. | 0.02 ° | ||
Accuracy | 0.1 ° | ||
Shear rate | 0.5 s-1 to 1000 s-1 influenced by capillary size and inclination | ||
1) depends on sample type and measuring settings, without changing the ball | |||
2) for the range in which the calibration constant was determined, not including uncertainty of reference standards |
Standards
ASBC
DIN
DIN EN ISO
Ph. Eur.
USP
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Chemicals | Viscosity and Density Measurement of Ionic Liquids/Solvent Mixtures Application Reports en
-
Medical | Lovis 2000 M/ME and DMA 4500 M: Viscosity Measurement of Whole Blood Application Reports en
-
Pharma | Lovis 2000 M/ME and pH ME: Viscosity and pH of Nasal Sprays or Eye Drops Application Reports en
-
Printing Ink: Gauging the Viscosity to Fine-Tune the Particle Size Calculation Application Reports en
Accessories & Software
Consumables
To find out if you can purchase online from your location, check the online availability below.
Check online availabilityIf you do not find the item you require, please contact your Anton Paar sales representative.

ADAPTER LUER CONE

Barcode scanner 2D with USB cable
Only for ViscoQC 300

BRUSH 175x25x2.7 NYLON 0.06 (5 PCS.)

Check valve silicone hose 3X5

Filling adapter UNF

Hose 190x3x2 PTFE "A"

Hose 2.5 x 4.5

Hose 2x4 Silicone

Hose 300x3x2 PTFE "AA"

Hose 750x3x2 PTFE "AD"

Hose Tygon 2375 I.D.=1,6 O.D.=3,2

Isoversinic Tubing I.D.=2 O.D.=4

MALE LUER PLUG PTFE

O-Ring 7.65X1.78 FFKM Chemraz 505

Patchkabel RJ45G SFUTP CAT5E 2M Crossove
Only for ViscoQC 300. Cable for LIMS Bridge connection to PC for transferring measurement data.

pH Electrode Foodtrode

PH ELECTRODE HAMILTON PH=0-14 0-80°

PRINTER CONNECTION CABLE

Silicone Tubing I.D.=3 O.D.=5

Syringes 10 ml Luer (100 pcs.)

Syringes 2 ml Luer (100 pcs.)

Syringes 5 ml Luer (100 pcs.)

TUBE d=2,1 D=2,4 L=20 1.4571

Viscosity standard AP N100 (100 ml)
280 / 86 / 9.7 mPa.s

Viscosity standard AP N100 (500 ml)

Viscosity standard AP N14 (500 ml)

Viscosity standard AP N1400 (100 ml)

Viscosity standard AP N1400 (500 ml)

Viscosity standard AP N26 C (100 ml)
Recommended for DIN/SSA/UL spindles

Viscosity standard AP N26 C (500 ml)

Viscosity standard AP N4000 (500 ml)

Viscosity standard AP N415 H (100 ml)
Recommended for DIN/SSA/UL spindles

Viscosity standard AP N415 H (500 ml)

Viscosity standard AP N7.5 M (100 ml)
Recommended for DIN/SSA/UL spindles

Viscosity standard AP N7.5 M (500 ml)

Viscosity standard AP N75 (500 ml)

Viscosity standard AP S3 L (100 ml)
Recommended for DIN/SSA/UL spindles

Viscosity standard AP S3 L (500 ml)

Viscosity standard AP S6 (500 ml)