Differential Scanning Calorimeter:
Julia DSC
- Patented air cooling: Peltier technology, no external cooler
- Reach -35 °C with one fast, quiet, and compact system
- Julia Suite software: No training needed to get up and running
- Step-wise guidance: Via measurement and calibration wizards
- Autosampler: Save time and costs with 24/7 automated measurements
Julia DSC: Speed Meets Precision. Anton Paar’s powerful new differential scanning calorimeter speeds everything up, to give you a competitive advantage where time and accuracy matter the most.
Learn to use it fast: Julia Suite eliminates the learning curve with intuitive navigation, step-by-step wizards, and easy-to-prepare methods – no training required.
Cool it down fast: Unmatched cooling rates take you down to subzero temperatures with a built-in air-cooling module.
Get your results fast: From experiment setup to final analysis, automation and smart presets ensure you get precise, trusted results in record time.
Key features
Learn to use it fast
Get from setup to results faster than ever with Julia Suite, our differential scanning calorimeter software. It eliminates the learning curve, guiding you effortlessly through every step – so you can start analyzing immediately.
- No training needed: Self-explanatory design lets you start right away
- Step-by-step calibration wizards: Accuracy with guided workflows
- Dedicated QC mode: Pre-set pass/fail criteria for easy quality control

Cool it down fast
The unique Julia DSC Air Cooling Module, powered by advanced Peltier technology, quickly reaches -35 °C without an external chiller. Say goodbye to cluttered lab spaces and complicated differential scanning calorimeter setups.
- Built-in air-cooling module: Unmatched cooling rates down to subzero temperatures
- Higher sample throughput: Fast cooling between measurements, from 300 °C to 25 °C in 7 minutes
- Fastest extension of cooling capabilities down to cryogenic temperatures: Swap cooling modules in less than 5 minutes

Get your results fast
Set up your differential scanning calorimeter and start in record time: Everything from setting up experiments to final analysis of the results is significantly faster than with any comparable device on the market.
- Pre-filled suggestions help you prepare methods in just a few clicks
- Streamlined navigation (e.g., when customizing graphs)
- Fast, automated calibration checks with performance history for reliable results

Efficient automation: Plan measurements over the weekend
The custom-designed Julia DSC autosampler increases your throughput and ensures accurate data and consistent results. Save time and reduce costs via automation of repetitive tasks. Seventy sample positions and eight dedicated reference positions help you plan all measurements efficiently 24/7, even over the weekend.

Thermal analysis accessories for sample preparation
A crucible sealing press is available for the Julia DSC series to enable quick, convenient sample preparation. The crucible die design ensures smooth placing, filling, sealing (cold welding), and weighing of the sample. With the filling funnel, powders can be easily placed into the crucible and the push rod helps to compact the sample to ensure good thermal contact. With the crucible closing pen, even the smallest available crucibles from Anton Paar can be closed, preventing the movement of film or fiber samples.

Specifications
ACM | RCM | NCM | |
Minimum temperature | -35 °C | -90 °C | -170 °C |
Maximum temperature | 700 °C | 600 °C | |
Maximum heating rate | 300 K/min | ||
Maximum cooling rate | 150 K/min | 200 K/min | |
Cooling 10 K/min down to | 5 °C | -55 °C | -150 °C |
Cooling 5 K/min down to | -15 °C | -70 °C | -160 °C |
Temperature accuracy (In) | <0.1 K | ||
Enthalpy accuracy (In) | <1 % | ||
Measurement range | ± 2,500 mW | ||
Julia DSC 300 | ✓ | – | – |
Julia DSC 500 | ✓ | ✓ | ✓ |
Standards
ASTM
ISO
DIN
Standards
ASTM
ISO
DIN
US Pharmacopoeia (USP)
European Pharmacopoeia (Ph. Eur.)
Japanese Pharmacopoeia (JP)
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
DSC Characterization of Common Rubber Compounds Application Reports
-
Determination of Oxidation Stability Using DSC Application Reports
-
Differential Scanning Calorimetry as a tool for Heat Capacity Determination Application Reports
-
Differential Scanning Calorimetry for Reliable Cure Monitoring of Epoxy Resins Application Reports
-
How Helium Improves Peak Separation of EVA Copolymer Application Reports
-
Thermal Behavior of Structured Fats for Plant-Based Foods Application Reports
-
Thermal Characterization of Lithium-Ion Battery Separators Application Reports
-
Thermal Properties of Recycled Polypropylene Application Reports
Similar products
Complementary products
If you do not find the item you require, please contact your Anton Paar sales representative.

Thermal Analysis Software:
Julia Suite Start
Julia DSC 300 | 500
- Basic thermal analysis software for the Julia DSC series
- Included free-of-charge in each instrument delivery
- Follow your measurement data live and adjust quickly if needed
- Accurate results, with calibration and measurement wizards

Thermal Analysis Software:
Julia Suite Professional
Julia DSC 300 | 500
- Advanced, upgradeable software for the Julia DSC series
- Detect overlapping thermal events with sinusoidal DSC
- Analyze relevant heat flow effects with the full set of analysis functions