Recommended Results

Tag Flash Point Tester: TAG 4

The automatic Tag closed-cup tester measures the flash point, the lowest temperature at which the vapors of a sample ignite upon the application of an ignition source. The tester can also be used to detect the ability of a sample to yield flammable vapors when maintained at an equilibrium temperature by the flash/no flash method.
TAG 4 is suitable for flash point applications of jet fuels, solvents, chemicals, etc.

Get in touch Document Finder

Key Features

Benefits at a Glance

  • Two cooling systems with Peltier elements are available: an economical air-cooled model and a low-temperature version with external water cooling
  • The two ignition systems in each unit give you the flexibility to work with an electric or gas igniter: if the gas ignition is used, the electric igniter will automatically relight the gas flame during the test, if necessary
  • The One-Twist swivel-around multi-function head guarantees the safe and easy one-hand connection of all sensors and actuators such as the shutter release, igniter and detector contacts
  • An extended measuring range up to 110 °C enables you to go beyond the conventional scope of the method

Convenient Operation

  • Test initiation by pre-installed standard test methods and ability to customize methods by user-defined programs
  • Outside flame sensors increase the system’s safety, especially for work with samples that have no conventional flash point but burn outside the test cup (e.g. due to flame-inhibiting components)
  • Splashproof touch-key panel with large LCD
  • A multi-detector combines the flash point detector and the temperature probe in a solid housing with a perfectly adjusted immersion depth

Customized User Flexibility

  • PC-software FPPNet (optional) for convenient remote handling and test data storage
  • Insulation hood (optional) to protect the cover and shutter assembly from icing during low-temperature flash point tests
  • Draft deflector (optional) recommended for gas ignition tests
  • Calibration set (optional)
  • Small-volume sample cup (optional)

Technical Specifications

Application range
(°C/°F selectable)
10 °C to 110 °C (air-cooled)
-30 °C to 110 °C (liquid-cooled)
Ignition Gas and electric (interchangeable)
Heating According to method or user-defined
Cooling of
Peltier elements
Air-cooled (by built-in fan)
Liquid-cooled (with tap water or circulation cooler)
Flash detection Thermocouple
Barometric pressure correction Automatic correction
Safety Overheat protection, automatic shut-off
Interfaces 2x RS232
Gas supply 50 mbar of propane or butane
Power supply 115 V/230 V, 50 Hz/60 Hz, 180 W (air-cooled)
230 V, 50 Hz/60 Hz or 115 V, 60 Hz, 150 W (liquid-cooled)
Dimensions 230 mm x 470 mm x 470 mm (W x D x H)
Weight 8 kg
Resolution 0.1 °C

Standards

A

ASTM D56
ASTM D3934
ASTM D3941

E

EN 924

F

FTM 791-1101

I

ISO 1516
IP 491
IP 492
ISO 1523

Documents

Accessories