Surface area and pore size analyzers:
NOVAtouch
High-throughput surface area and pore size analyzer
upon request
The NOVAtouch series are the instruments of choice for hundreds of labs globally. These rapid, high-throughput vacuum volumetric gas sorption analyzers provide quality control and research labs alike with the surface area and pore size analysis capabilities they require – and all this at an affordable price. Either two or four analysis stations with four built-in vacuum or flow degassing stations reduce the overall bench space while maximizing performance. A 21 CFR Part 11 compliant version of the software is available for pharmaceutical customers.
Technical specifications
General specifications | |
---|---|
Ambient temperature range | 15 °C to 40 °C |
Relative humidity | <80 % |
Dimensions (W x D x H) | 61.6 cm x 49.2 cm x 82.9 cm (24.3 in x 19.4 in x 32.6 in) |
Weight | 43 kg (95 lbs) |
Analysis specifications | |
---|---|
Analysis stations | 2 (NOVAtouch LX2) or 4 (NOVAtouch LX4) |
Adsorbates | Nitrogen, argon, carbon dioxide and any other inert gas |
Surface area range | 0.01 m²/g to no known upper limit |
Pore volume (STP) | <0.0001 cc/g |
Pore volume (liquid) | <2.2 x 10⁻⁶ cc |
Total pore volume | At user selectable P/P0 |
Pore size range | 3.5 Å* to 5000 Å (0.35 nm* to 500 nm) |
Reproducibility | <2 % (typical) |
Maximum analysis time | >40 hours (with liquid nitrogen) |
Coolant level control | CLS coolant sensor |
Number of degassing stations | Four (vacuum and flow capable) |
*3.5 Å to 20 Å range only covered using CO₂ on carbonaceous samples
Pressure specifications | |
---|---|
Pressure transducer accuracy | Within ±0.1 % of span |
Pressure range | 0 MPa to 0.13 MPa (0 torr to 1000 torr) |
Pressure resolution | 0.00006 torr (60 micro-torr) |
P₀ measurement | Periodic using dedicated P₀ transducer |
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Micropore Size Analysis of Porous Carbons Using CO2 Adsorption at 273.15 K (0 °C) Application Reports en
Consumables
To find out if you can purchase online from your location, check the online availability below.
Check online availabilityIf you do not find the item you require, please contact your Anton Paar sales representative.

2L Aluminum Dewar with handle

Cell-Seal, 12mm, Buna

Cell-Seal, 9mm, Buna

Dowel Pin, 12 mm

Dowel Pin, 6 mm

Dowel Pin, 9 mm

Level Sensor, CLS type, cryogen, long

Level Sensor, CLS type, cryogen, short

Level Sensor, CLS type, float, short

Level Sensor, Hybrid type, 77 K, long

Level Sensor, Hybrid type, 87 K, long

Non-elutriating Plug, 6 mm

Non-elutriating Plug, 9 mm

O-Ring, Viton 010, Brown, Pack of 2

O-Ring, Viton 12 mm, Brown, Pack of 2

O-Ring, Viton 9 mm, Brown, Pack of 2

Sample Cell Cap, FOR 6/9/12 mm Stems

Stem Cleaner, 6mm X 18" (Pack of 18)

Surface Area Reference Material, 2003

Surface Area Reference Material, 2005

Surface Area Reference Material, 2009

Vacuum Grease .25 Ounce

Vacuum Hose Assembly, 5' (1.5 m)