Ovo je obavezno polje.
Invalid
Broj dijela
Pogreška pri provjeri valjanosti!

Kinematic viscometer:
SVM

Model:
  • Automatic kinematic viscosity checks at a competitive price
  • Temperature range from 15 °C to 100 °C
  • Digital data handling: no stopwatch or manual calculations
  • Operator time per measurement: 5 min; only 1.5 mL of sample
  • Integrated ASTM bias correction for D445 results 
Samo internetska cijena | isklj.uklj. 0PDV
Cijena
na zahtjev
Informacije o kupnji
Kupi Anton Paar instrumente putem interneta
Broj dijela:
Provjerite dostupnost u internetskoj trgovini Zatražite ponudu Kupite ovaj proizvod putem interneta
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Exchange all your capillaries for one single unit and save enormous amounts of time and money: the SVM viscometers provide the highest flexibility by covering the entire viscosity, density, and temperature range with a single measurement cell and deliver results in seconds. With SVM you can certify jet fuel, diesel, biodiesel blends, and marine fuels; classify crude oils and determine the VI of your lubricant. Whatever challenge you face, the SVM viscometer is the best solution on the market.

Benefits

Ready to use out of the box
Ready to use out of the box
  • Plug & play: Use straight out of the box
  • Start up in less than 5 min
  • Instrument comes factory-adjusted

Challenge

You want to avoid tedious, time-consuming installation.

Solution

Installing SVM is incredibly easy: The instrument comes factory-adjusted and can be used right away – simply plug in the power supply and you’re ready to start.

Benefit

Start-up in <5 min. Use the instrument right out of the box.

Stand-alone solution
  • High traceability for test parameters and results
  • No need for external PC and software, saving costs and lab space
  • Guided user interface requires minimal training

Challenge

Glass capillary viscometers typically require an external PC with software. This takes up lab space, the software is tricky, and you have additional costs. Looking for a better solution?

Solution

SVM performs all your calculations automatically on the instrument without the need for an additional PC or software. The user interface is self-explanatory and you see the result directly on the screen.

Benefit

No PC and software costs. Lab space saved. Manual calculations obsolete. High traceability – test parameters and results are automatically saved. New staff are quickly able to operate the smart instrument.

Portable and battery-driven
  • Save valuable lab space
  • Low weight, easily portable
  • Optional battery for measurements away from the lab

Challenge

Temperature baths are heavy and occupy a large amount of lab space, especially when additional equipment such as counter-coolers is required.

Solution

SVM 1001 is space-saving, measuring only 26.5 cm x 36.5 cm x 18.0 cm, and weighs less than 6 kg. Additionally, the instrument can be powered by battery, making it easily portable and ideal for labs with little space.

Benefit

Occupies little lab space. Easy to move. Battery enables measurement away from the lab and acts as backup (uninterruptible power supply), so you can measure even in case of an outage.

Simple Fill
Simple Fill
  • Operational efficiency: Simple Fill relieves you to perform other tasks
  • Automatic drying and cleaning in place for more operator safety
  • No costs for syringe or pipette consumables

Challenge

You want to fill your sample directly from the container without having to use a pipette or syringe.

Solution

SVM 1001 Simple Fill allows direct sample loading: Simply pour the sample straight from the container into the funnel, and you’re ready to measure. The measuring cell is cleaned and dried in place, so the instrument is quickly ready for the next test.

Benefit

In-place filling, cleaning, and drying saves time and reduces the risk of glass breakage due to handling errors. Automatic sample loading eliminates operator-to-operator variability. No cost for syringe or pipette consumables.

Sample volume
  • Less than a quarter of the sample volume for glass capillary viscometers
  • Temperature equilibration in 1 min or less – fast test cycles
  • Reduced disposal costs and smaller environmental footprint

Challenge

Glass capillary viscometers require significant sample amounts (typically 25 mL), leading to long temperature equilibration times and test cycles. Higher sample volumes also mean higher disposal costs.

Solution

The compact measuring cell of SVM requires a sample size of only 1.5 mL. As a result, temperature equilibration takes only 1 min. or less. For ASTM-compliant tests requiring double determination, a sample size of 5 mL to 6 mL is needed.

Benefit

Temperature equilibration in just 1 min or less, reduced test cycle times, and lower disposal costs – all because typical sample volumes are less than a quarter of those for glass capillary viscometers.

Data management
  • Save costs with integrated features
  • Ensure traceability
  • Access all your data with just one click

Challenge

Usability, traceability, data integrity, and compliance are all crucial requirements for you. Your data handling and data transfer need to be efficient and seamlessly integrated into your IT network.

Solution

SVM ticks all the boxes. User-friendly software (incl. audit trail, electronic signature, and more with SVM 2001, 3001, 3001 Cold Properties and 4001), digital data handling, and the lab execution software AP Connect cover all your operational and regulatory requirements. 

Benefit

It’s easy to use – minimal training needed. You don’t have to worry about data loss or compliance issues in highly regulated industries. Enjoy simple data handling and data management with a single data platform.

Automation
Automation
  • 24/7 measurements
  • Reproducible filling and cleaning process
  • Robotic solutions for labs with high sample throughput

Challenge

You want fully automated measurements including operator-independent filling and cleaning.

Solution

Anton Paar’s sample changers can be attached, plug-and-play, via the integrated slot, offering fully automated filling and cleaning for up to 71 samples. We also offer customized robotic solutions, like our High Throughput Viscometer (HTV) for testing labs requiring high sample throughput.

Benefit

Minimum operator interaction eliminates operator dependency and ensures a reproducible process. Run measurements overnight and during weekends.

Safety
  • No glass breakage
  • No hot, flammable, or toxic liquids used for temperature control
  • Reduced exposure to hazardous solvents

Challenge

Glass capillaries often break during handling, which can be dangerous for the operator. Thermostat liquids can be hot, hazardous, and/or flammable. About 40 mL of solvent is needed for cleaning after each test – a huge amount of exposure for the operator. How can you avoid these dangers?

Solution

SVM has a robust metal measuring cell, and the Peltier temperature control makes it unnecessary to use a liquid bath or counter cooler to cover the full temperature range. Unlike capillary viscometers, SVM requires significantly less (min 1.5 mL / typ. 6 mL) solvent for cleaning.

Benefit

Zero risk of glass breakage, no flammable or toxic liquids required for temperature control. No health risk for operator and laboratory staff, due to smaller amount of hazardous solvents.

The all-in-one solution
  • 1 instrument, 1 test run – many results
  • 1 unbreakable measuring cell instead of 12 or more glass capillaries
  • No costly, additional capillaries and temperature baths

Challenge

Testing multiple parameters (e.g., kinematic viscosity, density, or cold flow properties) requires several instruments and is time consuming. Adding to this, covering a wide viscosity and temperature range needs numerous capillaries and baths, all of which have to be calibrated and maintained.

Solution

SVM delivers kinematic viscosity, density, viscosity index, cloud point, freeze point, and many more parameters in a single run. The instrument covers the entire measurement and temperature range with just a single measurement cell.

Benefit

Enjoy a significantly reduced workload thanks to multiparameter measurement. You can measure a wide variety of samples without changing capillaries. There’s no cost for purchase and maintenance of additional capillaries and temperature baths, and no need to guess the appropriate viscometer tube.

Compliance
  • D7042 is an ASTM/ISO/SAE-accepted alternative to D445
  • ASTM bias correction
  • Enjoy all the benefits of D7042 while reporting D445 results

Challenge

Product certification needs to follow standardized test methods. You want to take advantage of all the SVM benefits, but need to report D445 results.

Solution

SVM is compliant to ASTM D7042. This test method is referenced in a multitude of international standards and specifications as the ASTM/SAE/ISO-accepted alternative to D445. ASTM bias corrections allow you to report D445 results.

Benefit

Compliance is assured. With the integrated bias corrections delivered by ASTM, you can report D445 results while enjoying all the benefits of measuring with SVM.

Throughput
Throughput
  • 150 % higher throughput compared to manual methods
  • Higher operational efficiency, more profit per day
  • Faster results and rapid decisions to avoid out-of-spec production

Challenge

Manual testing with glass capillary viscometers is slow. Manual calculation of kinematic viscosity is error-prone. Errors during calculation require the measurement to be repeated.

Solution

SVM offers 150 % higher throughput compared to manual methods. Results are calculated automatically, leaving no room for human error.

Benefit

Faster measurement means that more samples can be measured per day. This increases operational efficiency. Automatic calculations save operator time and reduce the risk of error.

Temperature
  • Temperature equilibration in 1 minute or less
  • No external cooling down to -20 °C
  • Save on initial investment, energy costs, and lab space

Challenge

The recommended temperature equilibration time of 30 minutes causes long cycle times for manual tests. Furthermore, for measurements at (sub-)ambient temperatures, most kinematic viscometers need expensive and bulky counter-cooling equipment. 

Solution

Built-in Peltier temperature control and low sample volume enable equilibration times of one minute or less. No external cooling is needed down to -20 °C (with SVM 3001 and SVM 3001 Cold Properties), and high heating/cooling rates (up to 20 °C/min) significantly shorten waiting times between measurements.

Benefit

Temperature equilibration occurs in one minute or less, giving you super-fast measurements. You can save on acquisition costs, energy, and lab space. No counter-cooling needed.

Environmental impact
  • SVM offers superb return on investment (ROI)
  • Less than a quarter of the solvent needed for other capillary viscometers
  • 50 W energy consumption instead of 1000 W or more

Challenge

You want to minimize the environmental impact of your operation while reducing costs.

Solution

SVM helps you cut operational costs. The patented measuring cell requires only a small amount of solvent for cleaning (min. 1.5 mL/typ. 6 mL – instead of 40 mL for typical glass capillary viscometers), reducing solvent and disposal costs to a minimum. Alternatively, sample displacement eliminates the need for solvent. While delivering superior performance, SVM consumes much less energy (50 W) than a typical capillary bath (1000 W or more), regardless of whether you measure at -20 °C or at +135 °C.

Benefit

Significantly reduced energy and solvent consumption, as well as minimized disposal costs, and smaller environmental footprint. Premium economic efficiency.

Little effort
Little effort
  • Only 2 min of cleaning effort
  • Only 30 min downtime for tool-free routine maintenance
  • Break-proof measuring cell

Challenge

Maintenance of capillary viscometers is cumbersome and time-consuming. They need to be removed from the bath for cleaning, bath liquid may need exchanging, and capillaries need to be calibrated. Switching the bath back on and waiting for the temperature to stabilize takes several hours. As a result, the instrument is unavailable for extended periods. Also, glass capillaries may break during maintenance.

Solution

Routine maintenance on SVM takes 30 min. With capillary viscometers, it’s at least 1 hour. The patented motor concept enables tool-free access to the SVM’s measuring cell for convenient cleaning after measurement of heavily contaminated samples, such as used oils. The SVM measuring cell is made of break-proof metal.

Benefit

Exceptionally little cleaning effort (2 min) leads to exceptionally little downtime. No risk of glass breakage and thus no additional cost for purchasing or stocking replacement glass capillaries.

Reduce QC complexity
  • Only two calibrations
  • Reduce quality control documents by 50 %
  • Leaner and more efficient quality control

Challenge

Thermometers, stopwatches, and capillaries need to be calibrated regularly. This results in a huge number of certificates, reports, and other quality control documents.

Solution

With SVM, you only need to perform one calibration for viscosity and another for temperature. 

Benefit

Minimal number of documents for leaner and more efficient quality control. Real productivity instead of time spent calibrating. 

Global service network
  • Support from experts, trained and certified directly at Anton Paar
  • Inquiry response within 24 hours
  • Service networks: 86 locations, 350 certified service engineers

Challenge

You’re looking for a reliable local partner from purchase through application support to service.

Solution

Anton Paar has a worldwide service network of more than 30 subsidiaries and numerous responsible partners. This means an expert on your system is always close by. Service and support carry the Anton Paar seal of quality, attentiveness, and expertise.

Benefit

Benefit from Anton Paar’s certified support in your language and at one of our 86 service points worldwide. We are here for you, all the way. 

Tehničke specifikacije

  SVM 1001 SVM 1001
Simple Fill
SVM 2001 SVM 3001 SVM 3001
Cold Properties
SVM 4001
Patents AT5160588 (B1), US10036695 (B2), CN105424556 AT5160588 (B1), US10036695 (B2), CN105424556, AT516302 (B1), CN105628550
Test methods ASTM D7042, D445 bias corrected, ISO 23581, EN 16896 ASTM D7042, D445 bias corrected, ISO 23581, EN 16896
ASTM D4052, ISO 12185
ASTM D7042, D445 bias corrected, ISO 23581, EN 16896
ASTM D4052, ISO 12185
ASTM D2386 equivalent or better
ASTM D2500 equivalent or better
ASTM D7042, D445 bias corrected, ISO 23581, EN 16896
ASTM D4052, ISO 12185
Measuring Range
Viscosity 0.3 to 5,000 mm²/s 0.2 mm²/s to 30,000 mm²/s
Density --- 0 g/cm³ to 3 g/cm³
Temperature +15 °C to +100 °C (+59 °F to +212 °F) (one temperature as standard, second temperature optional) +15 °C to +100 °C  (+59 °F to +212 °F) -60 °C to +135 °C  (-76 °F to +275 °F) -60 °C to +100 °C  (-76 °F to +212 °F) +15 °C to +100°C  (+59 °F to +212 °F)
Precision
Viscosity repeatability* 0.1 %
Viscosity reproducibility* 0.35 %
Density repeatability* --- 0.0002 g/cm³ 0.00005 g/cm³
Density reproducibility* --- 0.0005 g/cm³ 0.0001 g/cm³
Cloud/freeze point repeatability* --- <0.5 °C / <0.5 °C ---
Cloud/freeze point reproducibility* --- <2.5 °C / <1.3 °C ---
Temperature repeatability 0.005 °C (0.009 °F)
Temperature reproducibility 0.03 °C (0.054 °F) from +15 °C to +100 °C 0.03 °C (0.054 °F) from +15 °C to +100 °C
0.05 °C (0.09 °F) outside this range
0.03 °C (0.054 °F) from +15 °C to +100 °C
Performance
Sample voume min. / typical 1.5 mL / 5 mL 3.5 mL / 8 mL 1.5 mL / 5 mL 2.5 mL / 6 mL
Solvent voume min. / typical 1.5 mL / 6 mL 5 mL / 10 mL 1.5 mL / 6 mL 2.5 mL / 10 mL
Max. sample throughput 37 samples per hour 21 samples per hour 33 samples per hour 30 samples per hour 24 samples per hour
Features
Optional upgrades Second temperature Automatic VI determination Chemical upgrade kit
Modularity with Abbemat refractometers 300/500, 350/550, 450/650
Modularity with Abbemat refractometers 300/500, 350/550, 450/650
Accessories Magnetic particle trap (MPT) None Magnetic particle trap (MPT)
Hot filling attachment (HFA)
Magnetic particle trap (MPT)
Automation None Integrated Simple Fill Filling Device Optional Autosampler (Xsample 340, 520, 530, 610, 630) + High-Throughput Platform HTV Optional Autosampler (Xsample 340, Xsample 530) + High-Throughput Platform HTV Optional Autosampler (Xsample 340, 530, 610, 630) + High-Throughput Platform HTV
Technical Data
Data memory 1,000 measurement results
HID (Human Interface Device) 7" touchscreen 10.4" touchscreen, optional keyboard, mouse, and 2D bar code reader
Interfaces 4 x USB (3 x A, 1 x B) 4 x USB (2.0 full speed), 1 x Ethernet (100 Mbit), 1 X CAN bus, 1 x RS-232, 1 x VGA
Compliance CE mark; EMC directive EN 61326-1; LV directive EN 61010-1; RoHS
Power supply At instrument: DC, 24 V /3A, AC adapter 90 VAC to 264 VAC, 47 Hat to 63 Hz, < 75W AC 100 V to 240 V, 50 Hz to 60 Hz, 250 VA max.
Ambient conditions +15 °C to +35 °C (+59 °F to +95 °F), max. 80 % r.h. non-condensing
Net weight in kg
(in lbs)
5.6 kg
(12.3 lbs)
6.6 kg
(14.6 lbs)
15.9 kg
(35.1 lbs)
17.6 kg
(38.8 lbs)
18.0 kg
(39.7 lbs)
17.8 kg
(39.2 lbs)
Dimensions
(W x D x H)
26.5 cm x 36.5 cm x 18 cm (10.4 in x 14.4 in x 7.1 in) 33 cm x 36.5 cm x 20.5 cm (13 in x 14.4 in x 8.1 in) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in)

*Attested at the points of the works adjustment or at calibration correction points, not including the uncertainty of the standards.

Standardi

Otvori sve
Zatvori sve

ABNT

NBR 10441 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
NBR 14358 3001, 3001 Cold Properties, 4001

ANP

Nº 804 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001

API

2540 3001, 3001 Cold Properties, 4001

ASTM

D341 2001, 3001, 3001 Cold Properties, 4001
D396 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D975 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D1250 3001, 3001 Cold Properties, 4001
D1655 3001, 3001 Cold Properties
D2161 2001, 3001, 3001 Cold Properties, 4001
D2270 3001, 3001 Cold Properties, 4001
D2501 3001, 3001 Cold Properties, 4001
D2502 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D2603 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D2880 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D3238 3001, 3001 Cold Properties, 4001
D3699 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D4052 3001, 3001 Cold Properties, 4001
D4054 3001, 3001 Cold Properties
D4174 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D4378 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D5002 3001, 3001 Cold Properties, 4001
D5275 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D5372 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D5621 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D6074 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D6080 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D6158 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D6278 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D6448 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D6666 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D6710 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D6751 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D6823 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D7042 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D7109 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D7152 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D7155 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D7223 3001, 3001 Cold Properties
D7467 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D7566 3001, 3001 Cold Properties
D7665 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D7666 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D7720 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D7752 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D7826 3001, 3001 Cold Properties
D7863 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D7973 2001, 3001, 3001 Cold Properties, 4001
D8029 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D8046 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D8128 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D8147 3001, 3001 Cold Properties
D8181 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
D8185 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
F3208 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
F3337 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001

CPTC

SH/T 0604-2000 ekv. ISO 12185 3001, 3001 Cold Properties, 4001

DEFSTAN

91-91 3001, 3001 Cold Properties

DIN

51659-2 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001

EN

590 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
14214 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
16734 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
16766 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
16896 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001

GB

T 29617 2001, 3001, 3001 Cold Properties, 4001

GJB

9131 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001

GOST

33 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001

IP

200 3001, 3001 Cold Properties, 4001
365 3001, 3001 Cold Properties, 4001
626 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001

IS

1460 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
1571 3001, 3001 Cold Properties

ISO

91 3001, 3001 Cold Properties, 4001
2909 3001, 3001 Cold Properties, 4001
12185 3001, 3001 Cold Properties, 4001
23581 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001

JIG

AFQRJOS 3001, 3001 Cold Properties

MIL

DTL-83133J 3001, 3001 Cold Properties
PRF-17331L 3001, 3001 Cold Properties

OENORM

C1109 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001

RANP

30 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
669 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001
778 3001, 3001 Cold Properties
804 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001

SAE

J300 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001

SH

T 0870 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001

SN

T 3518 1001, 1001 Simple Fill, 2001, 3001, 3001 Cold Properties, 4001

Certificirana usluga servisa Anton Paar

Kvaliteta usluge Anton Paar u usluzi i podršci:
  • Više od 350 tehničkih stručnjaka s certifikatom proizvođača širom svijeta
  • Kvalificirana podrška na vašem lokalnom jeziku
  • Zaštita za vaše ulaganje tijekom njegovog životnog ciklusa
  • Trogodišnje jamstvo
Saznajte više

Dokumenti

Slični proizvodi

Consumables, Accessories, Software & Reference materials

Consumables, Accessories, Software & Reference materials

Accessories & Software

Accessories & Software

Not all items are purchasable online in specific countries.

To find out if you can purchase online from your location, check the online availability below.

Samo internetska cijena | isklj.uklj. 0PDV

SYRINGES 5 ml LUER (100 pcs.)

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 6772

CABLE TIE HEAT-RESISTANT 100 pcs

Kompatibilan sa:
SVM 1001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 67216

HOSE 380x3x2 FEP 2x1/4"-28 UNF

Kompatibilan sa:
SVM 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 101713
Detalji o proizvodu
Connection hose FEP for SVM X001 labeled with "Cell" - "Sense"

ANGULAR SCREWDRIVER TORX T10

Kompatibilan sa:
SVM 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 21304

PROTECTIVE COVER DMA 501/1001 W. XS200

Kompatibilan sa:
SVM 1001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 220729
Detalji o proizvodu
made of PET/G for Xsample 200 (mat. no. 187517)

SYRINGES 10 ml LUER (100 pcs.)

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 6442

PROTECTIVE COVER DMA 501/1001 W. XS200HR

Kompatibilan sa:
SVM 1001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 220731
Detalji o proizvodu
made of PET/G for Xsample 200 High-Resistant (mat. no. 187548)

VISCOSITY STANDARD ANTON PAAR N100 100 ml - 280 / 86 / 9.7 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 100047
Detalji o proizvodu

280 / 86 / 9.7 mPa.s

ANGULAR SCREWDRIVER TORX T20

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 15462

VISCOSITY STANDARD ANTON PAAR N100 500 ml - 280 / 86 / 9.7 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 156771

"ADAPTER LUER LOCK 1/4""-28 UNF PEEK"

Kompatibilan sa:
SVM 1001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 104768

HOSE 250x3x2 FEP 2x1/4"-28 UNF "BB"

Kompatibilan sa:
SVM 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 17814

HOSE CLAMP DMIN 8.8 DMAX 9.3

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 21307

HOSE 5x8 VITON-BK ISO VERSINIC

Kompatibilan sa:
SVM 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 72546

VISCOSITY STANDARD ANTON PAAR N14 500 ml - 25 / 12 / 2.7 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 133282

VISCOSITY STANDARD APCL68 CCS (500 mL)

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 240447
Detalji o proizvodu
  • Low-temperature viscosity standard.
  • Viscosity values from 19,584 mPa.s (-15 °C) up to 11,417 mPa.s (-10 °C)

VISCOSITY STANDARD ANTON PAAR N4000 500 ml - 16000 / 2900 / 100 mPa.s

Kompatibilan sa:
SVM 1001 | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 133285

SYRINGES 2 ml LUER (100 pcs.)

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 6771

VISCOSITY STANDARD APCL60 CCS (500 mL)

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 132212
Detalji o proizvodu
  • Low-temperature viscosity standard.
  • Viscosity values from 21,961 mPa.s (-18 °C) up to 5,731 mPa.s (-5 °C)

VISCOSITY STANDARD ANTON PAAR N1400 100 ml - 5000 / 1200 / 74 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 165342

VISCOSITY STANDARD SET FOR SVM 1001 4x100 ml AP S3, N7.5, N26, N415

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 252433

VISCOSITY STANDARD ANTON PAAR N1400 500 ml - 5000 / 1200 / 74 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 133284

ADAPTER LUER CONE

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 63863

VISCOSITY STANDARD ANTON PAAR N26 (C) 100 ml - 50 / 21 / 4.2 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 100046
Detalji o proizvodu

Recommended for DIN/SSA/UL spindles

VISCOSITY STANDARD ANTON PAAR N26 (C) 500 ml - 50 / 21 / 4.2 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 81120

MALE LUER PLUG

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 63865

ACCESSORY KIT SVM 1001

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 244899

VISCOSITY STANDARD ANTON PAAR N415 (H) 100 ml - 1100 / 330 / 32 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 100048
Detalji o proizvodu

Recommended for DIN/SSA/UL spindles

VISCOSITY STANDARD ANTON PAAR N415 (H) 500 ml - 1100 / 330 / 32 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 81121

SET BATTERY HOLDER SVM 1001

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 252968
Detalji o proizvodu
1 pc. battery holder and 1 pc. cable for battery

HOSE 4X6 SILICONE

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 57024

VISCOSITY STANDARD ANTON PAAR N7.5 (M) 100 ml - 10 / 5.4 / 1.6 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 100035
Detalji o proizvodu

Recommended for DIN/SSA/UL spindles

PRINTER PAPER 57x30 STANDARD

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 59149

VISCOSITY STANDARD ANTON PAAR N7.5 (M) 500 ml - 10 / 5.4 / 1.6 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 81119

SYRINGE HOLDER

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 179990

VISCOSITY STANDARD ANTON PAAR N75 500 ml - 164 / 61 / 8.8 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 133283

PRINTER CONNECTION CABLE

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 64433

VISCOSITY STANDARD ANTON PAAR S3 (L) 100 ml - 3.7 / 2.3 / 0.9 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 100034
Detalji o proizvodu

Recommended for DIN/SSA/UL spindles

ADAPTER LUER 1/4" UNF

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 64792

VISCOSITY STANDARD ANTON PAAR S3 (L) 500 ml - 3.7 / 2.3 / 0.9 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 81118

PRINTER PAPER FOR EPSON TM-U220

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 89990

VISCOSITY STANDARD ANTON PAAR S6 500 ml - 8.8 / 4.7 / 1.5 mPa.s

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 133281

RIBBON CARTRIDGE FOR EPSON PRINTER TM-U220

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 90236

BRUSH 175x25x2.7 NYLON 0.06 (5 pcs.)

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 99778

ETHERNET CABLE FOR PC CONNECTION CAT5E, RJ45G-RJ45G, SFTP, 2 m, CROSSED

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 18597
Detalji o proizvodu

Only for ViscoQC 300. Cable for LIMS Bridge connection to PC for transferring measurement data.

VISCOSITY STANDARD APCL38 CCS (500 mL)

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 240446
Detalji o proizvodu
  • Low-temperature viscosity standard.
  • Viscosity values from 20,950 mPa.s (-25 °C) up to 2,670 mPa.s (-5 °C)

HOSE CLAMP DMIN 5.8 DMAX 6.5

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 21531

VISCOSITY STANDARD ANTON PAAR N2B 100 ml - 7.6 / 3.9 mPa.s at -20 / 0 °C

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 165355

CARRYING CASE SVM 1001

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 251911

ISO 17034-certified reference material:
Density standards 

Kompatibilan sa:
SVM 2001 | 3001 | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Detalji o proizvodu
  • Market-leading uncertainty of 0.015 kg/m³ (ISO 17034)
  • Application-specific density standards, available via webshop
  • Online certificate with lifetime reference values guarantee
  • Conformity with ISO requirements ISO 17025 and even ISO 17034
  • Safety glass ampoule for zero contamination

Više informacija

MAGNETIC PARTICLE TRAP SVM 1001 ONLY FOR SVM 1001 – NOT FOR Simple Fill

Kompatibilan sa:
SVM 1001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 245693

Grijani izmjenjivač uzoraka:
Xsample 610 

Kompatibilan sa:
SVM 2001 | 3001 | 4001
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Zagrijani izmjenjivač uzoraka:
Xsample 630 

Kompatibilan sa:
SVM 2001 | 3001 | 4001
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 186612

Dodatni pribor za SVM x001:
Magnetski hvatač čestica 

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Hot Filling Attachment for SVM™ X001

Dodatni pribor za SVM x001:
Priključak za vruće punjenje 

Kompatibilan sa:
SVM 2001 | 3001 | 4001
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Izmjenjivač uzoraka:
Xsample 340 

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 164759

Izmjenjivač uzoraka:
Xsample 530 

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 105700

DRYING CARTRIDGE

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 65085

KEYBOARD USA USB

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 80807

KEYBOARD GERMAN USB

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 80809

STAND FOR Xsample

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 87584

SAFETY WASTE CONTAINER

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 87585

PRINTER EPSON TM-U220D or B

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 93362

BARCODE SCANNER 2D WITH USB CABLE

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 189615
Detalji o proizvodu

Only for ViscoQC 300

PROTECTING COVER FOR KEYBOARD

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 13350
Detalji o proizvodu
In combination with keyboard (80809 or 80807)

RIBBON CARTRIDGE FOR CITIZEN PRINTER CBM910 / IDP3110

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 8139

Izmjenjivač uzoraka:
Xsample 520 

Kompatibilan sa:
SVM 2001 | 3001 | 4001
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 185550

Upravljanje gestama

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 176741

SVM 1001 Dual Temperature Option

Kompatibilan sa:
SVM 1001 | 1001 Simple Fill
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 251657

Lab execution software:
AP Connect Start

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 254078
Detalji o proizvodu
  • Now: 100 % discount at checkout!
  • Kickstart your paperless lab
  • Featuring key benefits of the Standard edition
  • Restricted to one instrument, single user access, one export rule

Više informacija

Lab execution software:
AP Connect Standard (subscription license)

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 254097
Detalji o proizvodu
  • Annual fee per instrument
  • Time-saving processes: automatic, digital data transfer
  • Top data quality: elimination of transcription errors
  • Fast decisions: data at your fingertips

Više informacija

Lab execution software:
AP Connect Standard (one-time license fee)

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 254081
Detalji o proizvodu
  • One-time fee per instrument
  • Time-saving processes: automatic, digital data transfer
  • Top data quality: elimination of transcription errors
  • Fast decisions: data at your fingertips

Više informacija

Lab execution software:
AP Connect Pharma (subscription license)

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 254118
Detalji o proizvodu
  • Annual fee per instrument
  • Time-saving processes: automatic, digital data transfer
  • Top data quality: elimination of transcription errors
  • Fast decisions: data at your fingertips

Više informacija

Lab execution software:
AP Connect Pharma (one-time license fee)

Kompatibilan sa:
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 254092
Detalji o proizvodu
  • One-time fee per instrument
  • Time-saving processes: automatic, digital data transfer
  • Top data quality: elimination of transcription errors
  • Fast decisions: data at your fingertips

Više informacija

AP DENSITY STANDARD DODECANE 1x10 mL, with ISO 17034 CERTIFICATE

Kompatibilan sa:
SVM 2001 | 3001 | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 242811
Detalji o proizvodu
  • Density standard with low density (750 kg/m³)
  • Organic liquid
  • Measuring uncertainty: 0.015 kg/m³
  • Specified temperature range: 15 °C – 50 °C
  • Durability: 18 months
  • Volume: 10 mL
  • ISO 17034-certified reference material
  • Complies with ISO 17025 and ISO 17034 requirements

AP DENSITY STANDARD OIL 30 cSt @ 40 °C 1x10 mL, WITH ISO 17034 CERTIFICATE

Kompatibilan sa:
SVM 2001 | 3001 | 4001
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 242814
Detalji o proizvodu
  • Density standard with low density (830 kg/m3)
  • Organic liquid
  • Viscous liquid
  • Measuring uncertainty: 0.015 kg/m³
  • Specified temperature range: 15 °C – 50 °C
  • Durability: 18 months
  • Volume: 10 mL
  • ISO 17034-certified reference material
  • Complies with ISO 17025 and ISO 17034 requirements