Packaged Beverage Analyzer:
PBA
- Selective alcohol determination via unique Alcolyzer technology
- Zero sample preparation: Results are more than 9x quicker than with conventional methods
- Modular setup with 30+ industry-specific parameters
- For all types of beer, cider, hard seltzer, and kombucha
Anton Paar’s Packaged Beverage Analyzers are single lab systems for every step of your beverage production process. Whereas PBA 1001 Beer is dedicated to confirming a craft beer’s final quality at a unique price/performance ratio, PBA 5001 Beer and PBA 5001 Wine meet every requirement of industrial manufacturers. All systems deliver customized, automated analysis in just three minutes – up to 9x faster than conventional methods.
Glavne značajke
The Packaged Beverage Analyzer’s simultaneous single-cycle measurement eliminates time-consuming calibration, minimizes cleaning, and saves you up to two hours a day. The system has a modular setup, and is configurable according to your needs. Filler performance, consistency of production, conformity with legal requirements and ultimate consumer satisfaction are all ensured.

Final quality assurance in three minutes
Crown your production control with confidence in the final product: Packaged Beverage Analyzers measure all key parameters directly from the final package. Rely on batch-to-batch consistency already at the storage tank and confirm after bottling so you conform with legal requirements. Immediately detect performance issues at the filler and optimize your filling process. The simultaneous analysis of all quality parameters with a single Packaged Beverage Analyzer reduces analysis time to just three minutes – over 9x quicker than conventional methods.

Selective alcohol and CO2 determination
Packaged Beverage Analyzers unite unique measuring principles for alcohol and CO2. Selectively determine alcohol content with Anton Paar's market-leading Alcolyzer and further selectively measure CO2 without influence from other sample ingredients. The system delivers certainty on tax declarations based on alcohol or CO2 levels, and enables you to nail down the CO2 concentration for each of your beer styles and thrill your customers with an unmatched taste experience – all without the need for sample preparation.

Zero sample preparation
The direct, pressurized filling of a sample in a Packaged Beverage Analyzer eliminates the need for sample preparation, use of glassware, and potential contamination of the product. It eliminates operator interaction with the sample and ensures airtight reliability of analysis results. The final package – either a can, glass bottle or PET bottle – is placed into the PFD filling device for direct sample transfer. The system can handle any package closure type.

Easy calibration and product-independent adjustment
The system is simply calibrated and adjusted with water and a binary solution. Fully automated instructions lead you through the calibration and adjustment procedure. New recipes aren’t a challenge: All samples are measured straight away, with no need for any product-specific calibrations.

Individual system setup, with upgrade possibility
The modular setup of the Packaged Beverage Analyzer lets you configure your ideal measurement solution, including the parameters you need. Analyze all required quality parameters from a single sample on a single system in a single measurement cycle and reduce complexity in your laboratory to a minimum. Choose from more than 30 parameters to set up your individual system – which can be upgraded anytime.
Tehničke specifikacije
PBA 5001 Beer | PBA 5001 Wine | PBA 5001 Softdrink | DMA 4101 | DMA 4501 | DMA 5001 | |
Measuring range | ||||||
Density | 0 g/cm³ to 3 g/cm³ | |||||
Temperature | 15°C / 20°C | 20 °C | 0 °C- 100 °C | |||
Pressure | up to 10 bar (145 psi) absolute pressure | |||||
Alcohol | 0 to 12 %v/v | 0 to 20 %v/v | - | - | - | - |
Original Extract | 0 to 30 °Plato | - | - | - | - | - |
Color (optional) | 0 to 120 EBC | - | - | - | - | - |
Concentration sugar actual | 0 °Brix - 15 °Brix | 0 °Brix - 80 °Brix | ||||
CO2 concentration | 0 vol. to 6 vol. (0 g/L to 12 g/L) at 30 °C (86 °F) 0 vol. to 10 vol. (0 g/L to 20 g/L) <15 °C (59 °F) | - | - | - | ||
O2 concentration | 0 ppm to 4 ppm | - | - | - | ||
pH value | pH 0 to pH 14 | |||||
Turbidity | 0 to 100 EBC / 0 to 400 NTU | |||||
Repeatability s.d. | ||||||
Density | 0.00001 g/cm³ (DMA 4101) 0.000005 g/cm³ (DMA 4501) 0.000001 g/cm³ (DMA 5001) | 0.00001 g/cm³ | 0.000005 g/cm³ | 0.000001 g/cm³ | ||
Temperature | 0.02 °C (0.04 °F) (DMA 4101) 0.01 °C (0.02 °F) (DMA 4501) 0.001 °C (0.002 °F) (DMA 5001) | 0.02 °C (0.04 °F) | 0.01 °C (0.02 °F) | 0.001 °C (0.002 °F) | ||
Alcohol | 0.01 %v/v | - | - | - | - | |
Original Extract | 0.03 °Plato | - | - | - | - | |
Extract | 0.01 %w/w | - | 0.015 %w/w | 0.01 %w/w | <0.01 %w/w | |
Color | 0.1 EBC | - | - | - | - | |
Concentration sugar actual | 0.015 °Brix (DMA 4101) 0.01 °Brix (DMA 4501) <0.01 °Brix (DMA 5001) | 0.015 °Brix | 0.01 °Brix | <0.01 °Brix | ||
CO2 concentration | 0.005 vol. (0.01 g/L) | - | - | - | ||
O2 concentration | 2 ppb (in the range <200 ppb) | - | - | - | ||
pH value | 0.02 (in the range pH 3 to pH 7) | |||||
Turbidity | 0.02 EBC / 0.08 NTU | |||||
General information | ||||||
Power features | U-View™, FillingCheck™, ThermoBalance™, full-range viscosity correction | |||||
Minimum amount of sample per measurement | 150 ml | 2ml | ||||
Typical measuring time per sample | 3 minutes (incl. filling) | |||||
Typical sample throughput | 15 samples per hour | |||||
Display | 10.1" TFT WXGA (1280 x 800 px); PCAP touchscreen | |||||
Controls | touchscreen, optional keyboard, mouse, and bar code reader | |||||
Internal storage | more than 10,000 measuring values with camera images | |||||
Power supply | AC 100 to 240 V, 50/60 Hz, fluctuation ±10 %, 190 VA | |||||
Communication interfaces | 5 x USB, Ethernet, CAN, RS232 | |||||
Dimensions (L x W x H) | 482 mm x 750 mm x 670 mm (19.0 in x 29.5 in x 26.4 in) | 482 x 730 x 446 mm (20.7 x 28.7 x 17.6 inches) | 526 mm x 347 mm x 230 mm (20.7 in x 13.7 in x 9 in) | |||
Weight | approx. 35.7 kg (77 lbs) | 22,4 kg (50 lbs) | ||||
Environmental conditions | (EN 61010) Indoor use only | |||||
Ambient temperature | 15 °C to 35 °C (59 °F to 95 °F) | |||||
Air humidity | non-condensing; 20 °C, < 90% relative humidity; 20 °C, < 90% relative humidity; 25 °C, < 60% relative humidity; 30 °C, < 45% relative humidity |
Standardi
AOAC
ASBC
BCoJ
EBC
GB
Mebak
Certificirana usluga servisa Anton Paar
- Više od 350 tehničkih stručnjaka s certifikatom proizvođača širom svijeta
- Kvalificirana podrška na vašem lokalnom jeziku
- Zaštita za vaše ulaganje tijekom njegovog životnog ciklusa
- Trogodišnje jamstvo
Dokumenti
-
Alcolyzer 3001 Data Sheet Brošure
-
Beer Analysis Overview Brochure Brošure
-
Wine Analysis Overview Brochure Brošure
-
pH 3101/3201 Data Sheet Brošure
-
Beverage | Hard Seltzer | Determination of alcohol content in Hard Seltzers Izvješća o zahtjevu
-
Beverage | Hard Seltzer | Process measurement for Hard Seltzer manufacturing Izvješća o zahtjevu
-
Determination of the alcohol content in kombucha with Alcolyzer 3001 Beer Izvješća o zahtjevu
-
From Measuring Result to Concentration - Using and Creating Quantities Izvješća o zahtjevu
-
PBA 5001 Beer SOP Priručnici
-
Hard seltzer: Analyzed in full compliance (Brauwelt International 2022/IV) Zákaznická zkušenost a publikace
Slični proizvodi
Potrošni materijal & Softver
Potrošni materijal & Softver
Softver
Softver
Da biste saznali možete li putem interneta kupovati sa svoje lokacije, provjerite dostupnost na mreži u nastavku.
Ako ne pronađete predmet koji vam je potreban, kontaktirajte svog prodajnog predstavnika tvrtke Anton Paar.

Interface caps DMA HR01 series
PBA 5001 Beer | 1001 Beer | 5001 Wine

INJECTION ADAPTER SDA/CARBOQC WITH HOSE FITTING
PBA 5001 Beer | 1001 Beer | 5001 Wine

PFD FILLING DEVICE PLUS
PBA 5001 Beer | 1001 Beer | 5001 Wine

SAMPLE CONDITIONER
PBA 5001 Beer | 1001 Beer | 5001 Wine

CAN/DEVICENET TERMINATING RESISTOR 5-POLES
PBA 5001 Beer | 1001 Beer | 5001 Wine

Lab execution software:
AP Connect Start
PBA 5001 Beer | 1001 Beer | 5001 Wine
- Now: 100 % discount at checkout!
- Kickstart your paperless lab
- Featuring key benefits of the Standard edition
- Restricted to one instrument, single user access, one export rule

Lab execution software:
AP Connect Standard (one-time license fee)
PBA 5001 Beer | 1001 Beer | 5001 Wine
- One-time fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

Lab execution software:
AP Connect Standard (subscription license)
PBA 5001 Beer | 1001 Beer | 5001 Wine
- Annual fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

Lab execution software:
AP Connect Pharma (one-time license fee)
PBA 5001 Beer | 1001 Beer | 5001 Wine
- One-time fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

Lab execution software:
AP Connect Pharma (subscription license)
PBA 5001 Beer | 1001 Beer | 5001 Wine
- Annual fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips