Measuring Systems for ViscoQC:
Spindle

Model:
  • L or RH set included in standard viscometer delivery
  • According to ISO 2555/ISO 1652
  • To measure in an open beaker (infinite gap)
  • Flexible cup holder for highest repeatability in viscosity results 
Samo internetska cijena | isklj.uklj. 0PDV
Cijena
na zahtjev
Informacije o kupnji
Kupi Anton Paar instrumente putem interneta
Broj dijela:
Provjerite dostupnost u internetskoj trgovini Zatražite ponudu Kupite ovaj proizvod putem interneta
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Save up to 15 seconds per test, when determining the viscosity of your samples, with the broad range of spindles and measurement systems available for ViscoQC. The magnetic spindle coupling is included for each spindle, and all spindles and measuring systems are automatically recognized - simplifying operation and avoiding manual user errors.

The best possible chemical resistance is guaranteed, as all spindles and bobs are made of high-quality stainless steel (AISI 316L). An optional spindle guard protects L/RH spindles during measurement and is traced by ViscoQC through TruGuard™. A flexible cup holder delivers reproducible results regardless of operator.

Izaberite svoju zemlju
Ako ne možete pronaći svoju zemlju na popisu , zatražite ponudu
Izaberite svoju zemlju
Americas
Canada
EN | FR
Colombia
ES
Mexico
ES
United States
EN
Europe
Austria
DE
Belgium
EN | FR
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Africa & Middle East
South Africa
EN
Turkey
TR
Asia-Pacific
Australia
EN
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
TH
Ako ne možete pronaći svoju zemlju na popisu , zatražite ponudu

Glavne značajke

L/RH spindles according to ISO 2555/ISO 1652

L/RH spindles according to ISO 2555/ISO 1652

L/RH spindles, so-called infinite gap systems, are included in each standard delivery of VisoQC100/300. Whereas the L-model contains 4 L spindles (L1-L4), the R- and H- models are delivered with 6 RH spindles (RH2-RH7). They are used within open 600 mL beakers, thus requiring at least 500 mL of sample volume if you want to measure standard-compliant. The optional Pt100 sensor for temperature sensing of your sample can be easily mounted on the beaker through its clamp. By the use of the flexible cup holder, you guarantee highest reproducibility, as different operators always have the same measurement position.  

Defined-gap measuring systems

Defined-gap measuring systems

Concentric cylinders (CC), double-gap systems (DG), ultra-low viscosity adapters (UL), and small-sample adapters (SSA) should be selected as defined gap systems when absolute viscosity values are required and sample volume (2 mL to 18.5 mL) is limited. To measure low-viscosity samples starting from 1 mPa·s, the DG or UL must be used. Highly accurate, air-cooled Peltier temperature control devices are available. To increase throughput and reduce cleaning to a minimum, the use of disposable cups for some systems is recommended.

Systems for low-temperature viscosity determination

Systems for low-temperature viscosity determination

The determination of the low temperature viscosity of lube and engine oils according to ASTM D2983/D8210 requires an insulated 4B2 measuring system. If ASTM D5133/D7110 needs to be fulfilled, the L1D22 system is available. Both systems are delivered with 100 pieces of disposable aluminum cups to reduce cleaning and enhance throughput. Ready-to-use methods are pre-installed on the ViscoQC 300 with a V-Curve software package for immediate start-up and easy operation. 

Systems to measure non-flowing samples

Systems to measure non-flowing samples

Non-flowing, highly viscous samples such as ointments, mayonnaise, and bentonite clay require a special technique for measurement. Standard measuring systems or spindles simply draw an air channel into the sample, resulting in meaningless viscosity readings, as they are not completely covered by the sample anymore. If a non-flowing sample does not contain any particles, the helical T-bar spindle movement through Heli-Plus or vanes can be used. If samples contain particles between 0.1 mm and 2 mm, vanes are the spindles of choice: They are highly viscous, and so a measurement directly within the sample container is possible. 

Tehničke specifikacije

Typical sample volume [mL] Particle size in sample [mm]
L/RH spindles 500 0.1 to 2
Concentric cylinder system (CC) 2 to 18.5 <0.1*
Double-gap system (DG) 7.5 <0.01
Ultra-low viscosity adapter system (UL) 16 <0.01
Small Sample Adapter System (SSA) 6.7 to 16.1 <0.01**
Insulated 4B2 system 20 <0.1
L1D22 system 16.1 <0.1
T-bar spindles 500 0.1 to 2
Vane spindles 500 0.1 to 2

Viscosity of the sample has to be considered to choose the proper spindle/measuring systems.
For more details refer to the FAQ section on the ViscoQC website.
* If a smaller bob is used in bigger cup, a bigger particle size is possible (< 0.5 mm)
** SC4-25, SC4-27, SC4-28, SC4-29, SC4-31, SC4-34 have a bigger measuring gap.

Standardi

Otvori sve
Zatvori sve

ASTM

D2983
D5133
D7110
D8210

DIN

3219
53019
54453

ISO

1652
2555

Certificirana usluga servisa Anton Paar

Kvaliteta usluge Anton Paar u usluzi i podršci:
  • Više od 350 tehničkih stručnjaka s certifikatom proizvođača širom svijeta
  • Kvalificirana podrška na vašem lokalnom jeziku
  • Zaštita za vaše ulaganje tijekom njegovog životnog ciklusa
  • Trogodišnje jamstvo
Saznajte više

Kompatibilni instrumenti

Slični proizvodi