Heated Sample Changer:
Xsample 631
- The multi-sample changer with no limits for high viscosities
- Handles up to 56 samples with heated (up to 95 °C / 200 °F) and non-heated samples at the same time
- Automated cleaning and drying
The Xsample 631 sample changer handles up to 36 heated sample positions for all Anton Paar master instruments. Improved heating leads to short heating periods, time saving, and increased performance. Temperatures up to 95 °C are achieved in the system. Even challenging samples can be measured according to strict ASTM standards. The robust design ensures reliable and maintenance-free operation. A removable magazine with dedicated non-heated positions saves time by facilitating sample handling and even makes a second measuring system obsolete.
Key features
Improved heating performance
- Short heating periods make the sample changer ready for measurement in no time.
- Even measurement of highly sensitive samples (e.g. waxes) can be performed by using the optional heated waste hose.
- Heating temperatures up to 95 °C can be achieved and the highest temperature stability is provided.
- Low power consumption resulting in energy savings is achieved by eight independent electrical heating circuits.
Easy sample handling
- Safe and easy collection of hot samples is facilitated by a removable magazine with a thermal handle.
- 36 heated positions allow for unattended and fully automated measurements.
- Optional non-heated positions for samples that are measurable at room temperature even make a second system obsolete.
- Low maintenance efforts due to electrical heating. No water bath that needs periodical inspection.
No cross-contamination due to the highest cleaning performance
- Inside and outside needle cleaning prevents sample cross-contamination and ensures the highest precision.
- Up to three different solvents can be used in any order to achieve optimal cleaning performance.
- Optimized cleaning performance is achieved by the use of different cleaning modes.
- Increased uptime of the instruments can be achieved by automated cleaning procedures directly after the measurements.
Technical specifications
Maximum temperature | 95 °C (203 °F) at 20 °C (68 °F) ambient temperature, no cooling |
Viscosity range with DMA M | |
Operation with internal air pump | Up to 10,000 mPa·s at 95 °C heating and measuring temperature |
Operation with 2 bar external compressed air | Up to 36,000 mPa·s at 95 °C heating and measuring temperature |
Viscosity range with SVM x001 | 0.2 mPa·s to 5,000 mPa·s at 95 °C heating and measuring temperature |
Filling mode | Pressure mode
|
Minimum sample volume per measurement | Approx. 4.5 mL with DMA M |
Number of sample vials | |
Magazine, heated positions only | 36 positions for 12 mL vials (only glass vials allowed!) |
Xsample heated / unheated positions | 32 positions heated / 24 positions unheated for 12 mL vials (only glass vials allowed!) |
Automatic filling and drying | Internal air pump of the master instrument or compressed air selectable |
Compressed air supply (optional) | Max. 2.0 bar (29 psi) relative |
Quality of air necessary | Class 3 according to ISO 8573-1: |
Environmental conditions (EN 61010) | Indoor use only |
Ambient temperature | 15 °C to 35 °C (59 °F to 95 °F) |
Air humidity | 10 % to 90 % relative humidity, non-condensing |
Pollution degree | 2 |
Overvoltage category | II |
Altitude | Max. 3,000 m (9,840 ft) |
Max. temperature of heated parts in case of malfunction | 160 °C (320 °F) |
Power supply | Power is supplied by the master instrument and the Xsample heating controller |
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Automated Viscosity Measurement of Raw Materials for Cosmetic Products Application Reports
-
Automated Viscosity and Density Measurements of Microcrystalline Waxes Application Reports
-
Xsample Series Brochure Brochures
-
Xsample 631 Reference Guide Manuals