This is a required field.
Invalid
Part number
Error in validation!

Inline Oxygen Sensor:
Oxy

  • +7
Model:
  • Hassle-free sensor-cap exchange with Toolmaster™
  • Predictable cap exchange with lifetime estimator
  • Ultimate comparability with Anton Paar solutions for laboratory and at-line measurements
  • Quick return to operational status after hot CIP/SIP or hot-water rinsing
  • Compact stand-alone solution for inline oxygen measurement in CO₂ recuperation lines
  • Compact stand-alone solution with analog outputs and HMI
  • Hassle-free sensor-cap exchange with Toolmaster™
  • Digital input to process stop signal during CIP/SIP routine
  • Quick return to operational status after CIP/SIP
  • Optical measuring principle comparable to lab and at-line solutions
Pick your country.
Europe
Austria
DE
Belgium
EN | FR
Croatia
EN
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Asia-Pacific
Australia
EN
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Philippines
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
EN
Vietnam
EN
Americas
Brazil
PT
Canada
EN | FR
Colombia
ES
Mexico
ES
Peru
ES
United States
EN
Africa & Middle East
South Africa
EN
Turkey
TR
If you can't find your country in the list get a quote

The Oxy 4100/5100 inline oxygen sensors measure dissolved oxygen (DO) in real-time, directly at the production line. They provide accurate, drift-free measurements throughout the entire production process.

Oxy 5100 can easily be combined with additional process sensors from Anton Paar to meet all future production- and quality-control requirements. The Oxy 4100 transmitter comes ready with analog outputs and a touchscreen interface.

The CO₂ Purity Monitor features a compact system for monitoring the O₂ content in pressurized CO₂ recuperation pipes.

Key features

Inline oxygen sensor: Clever sensor caps – no calibration needed

Inline oxygen sensor: Clever sensor caps – no calibration needed

The Oxy 4100/5100 sensor caps embody the smart connection of the sensor with the sample. To match individual requirements, the right sensor cap can be chosen from a variety of caps. Conveniently switch between the ranges by simply exchanging the sensor cap.

All required calibration parameters are stored in the sensor cap of the inline oxygen sensor. The Toolmaster® technology automatically detects the sensor cap and transfers all setup parameters to the sensor. Once the cap is mounted, inline measurement can start immediately.

Lifetime estimator: Easy planning of sensor cap exchange

Lifetime estimator: Easy planning of sensor cap exchange

Only Oxy 5100 supports the steps involved in setting up a predictive maintenance schedule for inline measurement.

The Oxy 5100 lifetime estimator estimates the remaining service life of the sensor cap in days and warns you when a new sensor cap is required. Warnings are automatically shown on the sensor display, and an updated lifetime estimation can be requested at any time.

Hygienic design: EHEDG-certified and SIP-ready

Hygienic design: EHEDG-certified and SIP-ready

The Oxy 4100/5100 inline oxygen sensors are suitable for hygiene applications in the beverage, pharmaceutical, and water treatment industries. Oxy 5100 fulfills international hygienic standards because it is EHEDG-certified Type EL – Class I and can be cleaned using all common CIP procedures. All materials that are in contact with the sample are FDA-compliant.

Oxy 4100/5100 is designed for cleaning and sterilization at temperatures up to 130 °C. The sensor is ready for in-spec operation only a few minutes after cleaning and sterilization, reducing downtimes to a minimum.

Plug and play: Easy setup with maximum compatibility

Plug and play: Easy setup with maximum compatibility

No special training is required to commission and operate the instrument. The sensor series are set up quickly and can be easily used with the touchscreen interface of the built-in evaluation unit, via the Pico 3000 software, or with the help of the mPDS 5 evaluation unit.

Oxy 5100 can be easily adapted to support several communications protocols including analog (4 mA to 20 mA), Modbus RTU, Modbus TCP, HART, PROFIBUS DP, PROFINET IO, and EtherNet/IP. The Oxy 4100 transmitter comes ready with analog outputs and a touchscreen interface.

Fully control the purity of the CO₂ recuperation process

Fully control the purity of the CO₂ recuperation process

The CO₂ Purity Monitor features a compact system for monitoring the O₂ content in pressurized CO₂ lines. Driven by Oxy 5100, in combination with the integrated pressure sensor for automatic pressure compensation, the CO₂ Purity Monitor is a compact, stand-alone solution.

For a non-pressurized measuring point, Oxy 5100 and the clever sensor caps are installed right after the conditioning system is set up.

Technical specifications

Sensor caps Ultra-trace range** Trace range* Wide range Ultra-wide range**
Measuring range (dissolved O₂ in liquids) - (Gas phase only) 0 ppb to 2000 ppb 0 ppm to 22.5 ppm 0 ppm to 45 ppm
Measuring range (gas phase O₂ in CO₂) 0 ppmv to 200 ppmv
(0 hPa to 0.2 hPa)
0 % to 4.2 % O₂
(0 hPa to 40 hPa)
0 % to 50 % O₂
(0 hPa to 500 hPa)
0 % to 100 % O₂
(0 hPa to 1000 hPa)
Accuracy for liquids (the larger value is valid) - (Gas phase only) ≤ ± 1 ppb or ± 3 % ≤ ± 0.042 ppm or ± 3 % ≤ ± 0.1 ppm or ± 5 %
Accuracy in gas phase (the larger value is valid) ≤ ± 2 ppmv or ± 5 % ≤ ± 25 ppmv or ± 3 % ≤ ± 0.1 % O2 or ± 3 % ≤ ± 0.2 % O2 or ± 5 %
Sample temperature (non-freezing) 0 °C to 40 °C -5 °C to +65 °C
(Oxy 4100: -5 °C to +40 °C)
-5 °C to +65 °C
(Oxy 4100: -5 °C to +40 °C)
-5 °C to +40 °C
CIP/SIP temperature Not suitable for CIP/SIP max. 99 °C, max. 130 °C (max. 30 min)
Line pressure max. 12 bar abs. (174 psi abs.), max. 5 bar abs. (72 psi abs.) for measurements in gas phase
Certifications - EHEDG (Type EL - Class I)**
Measuring Interval 1 to 360 s (Oxy 4100: 15 s)
Ambient temperature / Humidity -5 °C to +50 °C / 0 % rH to 90 % rH (non-condensing)
Power supply SELV DC 24 V (DC 20 V to 30 V), max. 1.6 W
Dimensions (HxWxD) Oxy 4100/5100: 162x162x215 / Pressure sensor for CO2 Purity Monitor: 80x80x120

* Special sensor cap type available for harsh process conditions. Contact your Anton Paar representative.
** Not available for Oxy 4100.

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Categories
Industry
Application
Product
Your choice: Reset all filters

No results found!

See more

Consumables

Consumables

Not all items are purchasable online in specific countries.

To find out if you can purchase online from your location, check the online availability below.

OXY 4100 / 510 / 5100 SENSOR CAP WR 0 TO 22.5 ppm / 0 TO 50 % O2 (DO / GAS)

Compatible with:
Oxy 4100 | 5100
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 239522
Product details

Replaces material 176420 DO Sensor cap wide range.

OXY 4100 / 510 / 5100 SENSOR CAP TR 0 TO 2000 ppb / 0 TO 4.2 % O2 (DO / GAS)

Compatible with:
Oxy 4100 | 5100
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 239523
Product details

Replaces material 176421 DO Sensor cap trace.

OXY 4100 / 5100 SENSOR CAP TR PTFE 0 TO 2000 ppb (DO)

Compatible with:
Oxy 4100 | 5100
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 239527
Product details
Sensor cap for dissolved oxygen measurements with improved chemical resistance and highest measurement stability. All required calibration parameters are stored in the sensor cap. The Toolmaster technology detects the sensor cap and transfers all setup parameters to the sensor automatically for quick and easy cap exchange. Scope of delivery 1 Pcs. Sensor cap trace range PTFE Technical specifications
- Accuracy at 20 °C : max. ± 1 ppb or ± 3 %
- Measuring range: 0 ppb to 2000 ppb
- Sample temperature Oxy 4100: -5 °C to + 40 °C, non-freezing
- Sample temperature Oxy 5100: -5 °C to + 65 °C, non-freezing
- Wetted materials: Stainless steel 1.4404 (AISI 316L), PTFE (FDA-approved) and FKM 75.16-04 (FDA-approved)
- Response time: t90 < 100 s

OXY 5100 SENSOR CAP ULTRA-WIDE RANGE 0 TO 45 ppm / 0 TO 100 % O2 (DO / GAS)

Compatible with:
Oxy 4100 | 5100
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 239526
Product details
Sensor cap for oxygen measurements in liquids and gases. All required calibration parameters are stored in the sensor cap. The Toolmaster technology detects the sensor cap and transfers all setup parameters to the sensor automatically for quick and easy cap exchange. Scope of delivery 1 Pcs. Sensor cap ultra-wide range Technical specifications
- Accuracy at 20°C (liquid phase) : max. ± 0.1 ppm or ± 5 %
- Accuracy at 20°C (gas phase) : max. ± 0.2 % O2 or ± 5 %
- Measuring range (liquid phase) : 0 ppm to 45 ppm
- Measuring range (gas phase) : 0 % O2 to 100 % O2 (0 hPa to 1000 hPa)
- Sample temperature: -5 °C to +40 °C, non-freezing
- Wetted materials: Stainless steel 1.4404 (AISI 316L), Silicone (FDA-approved) and FKM 75.16-04 (FDA-approved)
- Certifications: EHEDG (Type EL Class I)

OXY 5100 SENSOR CAP ULTRA-TRACE RANGE 0 TO 200 ppmv (GAS)

Compatible with:
Oxy 4100 | 5100
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 233207
Product details
Sensor cap for oxygen measurement in ultra-pure gases such as highly purified CO2 and N2. All required calibration parameters are stored in the sensor cap. The Toolmaster technology detects the sensor cap and transfers all setup parameters to the sensor automatically for quick and easy cap exchange. Scope of delivery 1 Pcs. Sensor cap ultra-trace range Technical specifications
- Accuracy at 20°C : max. 2 ppmv or ± 5 %
- Measuring range: 0 ppmv to 200 ppmv (0 hPa to 0.2 hPa)
- Sample temperature: 0 °C to +40 °C, non-freezing
- Wetted materials: Stainless steel 1.4404 (AISI 316L), Silicone and FKM 75.16-04 (FDA-approved)