This is a required field.
Invalid
Part number
Error in validation!

Particle Size Analyzer:
PSA

  • media
  • +8
  • 360°
Model:
  • Multi laser system
  • Measurement range liquid: 0.04 µm to 2500 µm
  • Measurement range dry: 0.1 µm to 2500 µm 

With the laser diffraction technology of the PSA series you can determine the particle size and particle size distribution of both – liquid dispersions and dry powders from the nanometer up to the millimeter range. The knowledge of the material’s particle size and size distribution is essential for product development and quality control as these two parameters have an impact on the processability as well as the properties of the final product. The instruments of this series incorporate more than fifty years of experience. The world’s first laser diffraction particle size analyzer – the first-ever PSA – was invented in 1967.

Key features

Compact 2-in-1 design to measure both wet and dry samples

Compact 2-in-1 design to measure both wet and dry samples

PSA instruments are the only particle size analyzers that can be configured with fully integrated liquid and dry dispersion modules within one instrument. Sample dispersion as well as the measurement take place inside the instrument. This unique design eliminates the need for the operator to handle several accessories, exchange the hardware, or make manual adjustments. The software enables the switching between liquid and dry dispersion mode with a single mouse click, which saves time and prevents operation errors. 

Multi-laser technology for a broad measurement range

Multi-laser technology for a broad measurement range

The multi-laser technology provides an extensive range of measurable particle sizes. The single-laser PSA 990 covers a measurement range of 0.2 μm to 500 μm. For an even broader range, PSA 1090 and PSA 1190 have a unique optical design for diffraction analysis, which includes multiple lasers. While PSA 1090 has been designed with two lasers to resolve particles as small as 40 nanometers, PSA 1190 contains an additional third laser to cover the full measurement range of up to 2.5 millimeters. The use of solid state lasers ensures that instruments of the PSA series are ready to measure right after being switched on as nearly no warm-up time is required.

Accurate size distribution of dry powders

Accurate size distribution of dry powders

The size distribution of dry powders is often difficult to measure because the particles tend to agglomerate, which falsifies the results. Dry Jet Dispersion (DJD) technology is Anton Paar’s patented technique (FR2933314) for efficiently dispersing and precisely analyzing powder particles. The innovative design features an air pressure regulator that quickly and easily adjusts the air flow in accordance with the sample properties. The shear forces created by the air flow separate agglomerated particles ensuring that primary particles are detected. 

Accuracy, repeatability, and stability for a lifetime

Accuracy, repeatability, and stability for a lifetime

Anton Paar’s particle size analyzers are fully ISO 13320 compliant to meet the requirements for traceable, accurate, and repeatable results. The unique design of the lasers and the optical bench set the market standard for a measurement reproducibility that is better than 1 % variation. Furthermore, the optical bench design has all optical components permanently mounted on a cast-iron base plate. This ensures realignment-free operation, making PSA the ideal instrument not only for R&D environments, but also for harsh environments. Thus, accuracy, reproducibility, and stability are guaranteed for the instruments’ entire life time. 

Technical specifications

  PSA 990 PSA 1090 PSA 1190
Measurement principle Laser diffraction
Measuring range (dry) 0.3 μm to 500 μm 0.1 μm to 500 μm 0.1 μm to 2500 μm
Measuring range (wet) 0.2 μm to 500 μm 0.04 μm to 500 μm 0.04 μm to 2500 μm
Dry dispersion Venturi Venturi Venturi/Freefall
Liquid dispersion 2 peristaltic pumps/ultrasonic transducer/stirrer
Repeatability <1 %
Accuracy <3 %
Measuring time <1 min
Number of lasers 1 2 3
Laser safety classification FDA Title 21 CFR - Part 1040 & EN 60825-1:2014
Laser class, closed cover  Class 1 of EN 60825-1:2014
Laser class, open cover  Class 3R of EN 60825-1:2014
Digital data security FDA Title 21 CFR - Part 11
Electromagnetic compatibility  EN 61326-1:2013
Low voltage EN 61010-1:2010 & EN 61010-2-081:2015
Dimensions (L x D x H)  890 mm x 530 mm x 430 mm; 35 in x 21 in x 17 in
Weight ~55 kg

Standards

Open all
Close all

ASTM

B822 – 20
D4464 - 15(2020)
E2316 - 14(2019)

ISO

13320:2020

U.S. Pharmacopoeia (USP)

429

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Categories
Industry
Application
Product
Your choice: Reset all filters

No results found!

See more

Consumables, Accessories & Software

Consumables, Accessories & Software

Accessories & Software

Accessories & Software

Not all items are purchasable online in specific countries.

To find out if you can purchase online from your location, check the online availability below.

HOSE CLAMP 16-27MM 1.4301

Compatible with:
PSA 1190 | 1090 | 990
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 76393

PSA MEASUREMENT CELL LIQUID 1190

Compatible with:
PSA 1190
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 186093

PSA MEASUREMENT CELL LIQUID 990 AND 1090

Compatible with:
PSA 1090 | 990
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 186092

PARTICLE SIZE STANDARD PS 413 SIZE RANGE 10 - 100 µm

Compatible with:
PSA 1190 | 1090 | 990
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 264642
Product details
Particle size standard for validating Zoom and Standard objectives with Liquid Flow dispersion unit

PARTICLE SIZE STANDARD PS 234 SIZE RANGE 150 - 650 µm

Compatible with:
PSA 1190 | 1090 | 990
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 264643
Product details
Particle size standard for validating Standard objective with Free Fall dispersion unit

COVER FOR LIQUID TANK - STAINLESS STEEL

Compatible with:
PSA 1190 | 1090 | 990
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 252201
Product details
Stainless steel cover for the liquid tank in the Liquid Flow dispersion unit

PARTICLE SIZE STANDARD PS414 (10-100 µm)

Compatible with:
PSA 1190 | 1090 | 990
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 264870

OPTICAL CLEANING WIPES 10x10cm, (PACK OF 300 PCS)

Compatible with:
PSA 1190 | 1090 | 990
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 220896

T-HOSE CONNECTOR 6 mm

Compatible with:
PSA 1190 | 1090 | 990
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 17759

VITON UPGRADE KIT FOR SVU 

Compatible with:
PSA 1190 | 1090 | 990
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 210274

HOSE 10X16 PVC

Compatible with:
PSA 1190 | 1090 | 990
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 186835

PSA CLEANING STRIPS FOR MEASUREMENT CELL LIQUID (1 pack = 50 Pcs.)

Compatible with:
PSA 1190 | 1090 | 990
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 188968

NUMATIC HZ200 DUSTBAGS (10 pcs.)

Compatible with:
PSA 1190 | 1090 | 990
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 199002

Automation Option for Particle Analysis:
Litesizer Autosampler 

Compatible with:
PSA 1190 | 1090 | 990
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Measure liquid and dry samples 
  • Conduct liquid and dry mode measurements in the same run
  • Measure up to 60 samples per run
  • Add and prioritize samples even during an active run
  • Ensure safety with cobot functionality

More info

Small Volume Unit

Compatible with:
PSA 1190 | 1090 | 990
More info
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months

Software for particle analysis:
Kalliope 

Compatible with:
PSA 1190 | 1090 | 990
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Particle analysis software for the Litesizer DLS Series, PSA Series, and Litesizer DIA 500
  • Start your particle measurements in just three clicks
  • One-page workflow user interface
  • Live monitoring of measurement results, analysis function, customizable reporting, and multiple exporting capabilities

More info