Recommended Results

  • Powerful device in a robust design
  • Everything on one screen
  • Easiest sample handling with virtually no sample preparation
  • From a few µl to 2mL of sample.

TORC 5000 - Thermo-optical Oscillating Refraction Characterization

The Optics Route to Thermal Analysis

TORC 5000 features unique technology in a robust and compact instrument and combines this with powerful measurement software. The Thermo-optical Oscillating Refraction Characterization (TORC) technique enables determination of the coefficient of thermal expansion and monitoring of phase and glass transitions. TORC 5000 is an interesting and economic solution for adhesive and polymer manufacturers, e.g. to monitor curing, polymer reactions as well as the temperature- and time-dependent behavior of samples.

Get in touch

Key Features

Easy to operate PC software

  • Easy management of measurements in a workbook structure
  • Monitoring the measurement process via a live result plot
  • Predefined measuring modes 

Compact and robust design

  • Small footprint (smaller than a football)
  • Resistant sapphire measurement surface with hardness close to diamond
  • Rugged fully anodized aluminum body
  • Waterproof and dustproof measuring unit acc. to IP 68

Ready to use immediately 

  • No temperature calibration needed for daily measurements
  • Customer calibration within seconds with a water reference
  • Factory calibrated with PTB (National Metrology Institute of Germany) standards for refractive index

The most precise temperature control

  • Easy to use Peltier temperature control
  • Accuracy of ±0.03 °C across a temperature range from 4 °C to 125 °C
  • Pre-heating or cooling of sample well for fast measurement and minimal temperature perturbation of sample e.g. to maintain crystal modification

Flexible sample volume

  • From a few µL up to 2 mL of sample measurable

 

 

Technical Specifications

Refractive index*
Range (nD) 1.26 to 1.72
Resolution (nD) ±0.000001
Accuracy (nD) ±0.00002
Accuracy (dn/dT) ±0.00001
Temperature
Range 4 °C to 125 °C
Heating rate/cooling rate 0.001 °C/min to 10 °C/min
Temperature accuracy ±0.03 °C
Temperature resolution ±0.001 °C
Min. temperature modulation amplitude 0.1 °C
Min. temperature modulation period 10 s
Temperature control Peltier
Material in contact with sample
Prism Synthetic sapphire
Sample well Stainless steel
Seal FFKM
Components
Light source LED light source, average lifetime > 100000 h
Wavelength 589 nm (by wavelength-adjusted interface filter)
Power requirements 100 to 240 VAC ±10 %, 50/60 Hz, min. 10 W, max. 200 W, depending on sample temperature setting and ambient temperature
Dimensions
WxHxD [mm] Measuring unit: 195 x 135 x 194
Communication unit: 215 x 95 x 190
Weight [kg] Measuring unit: 6.1
Communication unit: 3.7
Further specification
Protection class Measuring unit: IP68**

*valid at standard conditions (T = 20 °C, λ = 589 nm, ambient temperature = 23 °C)
**2 hours at 1 meter depth

Accessories

Your choice: Reset all filters X
Industry
Industry Group
Standards
Showing to of